Power Supply 33.6 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 100000 Pieces per Month other pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features:
Constant Current LED Driver
I/P:100-240V 50/60Hz
O/P: 3 options below
Model No. LD035H-CU14024-15 for DC12-24V 1400mA 33.6W Max
Model No. LD035H-CU10532-15 for DC21-32V 1050mA 33.6W Max
Model No. LD035H-CU07048-15 for DC25-48V 700mA 33.6W Max
Waterproof packaging:IP65 for dry location and wet location
UL,cUL,CE,ROHS Approval
Dimension: 130L*45W*35 Hmm
Parameter | Symbol | LD035H-CU14024-20 | LD035H-CU10532-20 | LD035H-CU07048-20 |
|
Input Voltage | Vin | 100-240v | 100-240v | 100-240v |
|
input Frequency | F | 50/60HZ | 50/60HZ | 50/60HZ |
|
Output Voltage | Vo | 12-24DCV | 21-32DCV | 25-48DCV |
|
Output Power | Po | 33.6W | 33.6W | 33.6W |
|
Output Current | Lo | 1400mA +6% | 1050mA +6% | 700mA +6% |
|
Certificate&size | UL,cUL,CE&ROHS,85L*54W*32.5H(mm) |
- Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- To 30VA/ square meters, the transformer needs 30KVA, with two 120 square copper wire. Specific should be used to determine the total power of the lighting transformer.
- Q:Why should lighting transformers be used in factories and mines?
- But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
- Q:How to calculate the rated capacity of small transformers for lighting purposes?
- Capacity of power transformer is the basic equipment for a total capacity of [kW] (maximum power consumption rate by a / X100 capacity) divided by the power load [%] value for benchmarking.
- Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Now is the three standard power supply, fire, fire and a single, zero line is three 220V, the fire is 380V. 40W lights can be 25.
- Q:How many A leakage protection switches are used in 5000VA lighting transformers?
- Secondary current =5000VA/220=22A, you can select the 32A leakage protection switch.
- Q:Why is the two side of the lighting transformer grounded?
- Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
- Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Generally, the power of the transformer is the apparent power, and the light bulb is the active power, and the power matching is taken into account.
- Q:What's the function of the lighting transformer?
- Applies to some requirements for safe voltage 24V - 36V lighting sites. Such as: basement, tunnel, dangerous goods warehouse and so on. Then there is the (mobile, temporary) safety lighting for the overhaul.
- Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- The number of tables in this table is increasing when the table rings to show 1.Method 2 is only to measure the capacitance is good or bad, can not be measured capacity.
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- Double winding type safety isolating transformer load end and the power supply terminal is not connected, is safe, and autotransformer primary winding of a share, it is directly connected with the power supply end of the power, not safety.
1. Manufacturer Overview |
|
---|---|
Location | Guangdong,China (Mainland) |
Year Established | 2005 |
Annual Output Value | |
Main Markets | North America 0.36% South America 1.26% Eastern Europe 0.36% Western Europe 1.41% Central America 6.22% Northern Europe 0.36% Southern Europe 1.41% Domestic Market 88.62% |
Company Certifications | TUV; Business License |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 2 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
Power Supply 33.6 Watt
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 100000 Pieces per Month other pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords