The transformer zero line has broken, has the result to the household illumination circuit?
The power supply system in three-phase four line zero line is broken, the breakpoint of the single-phase circuit (220V) electrical burn by voltage to 380V. I met, the incandescent lamp suddenly particularly bright then the blow up of internal fuse TV has burned out. So in the three-phase four wire power supply system zero line asked to do repeat grounding in households is the reason.
What type of low voltage transformer should be adopted for safety lighting power supply?
We have produced many low voltage lighting transformers, such as outdoor waterproof, high-power stage lighting, as well as indoor small power transformers, customer response, but also good! For example, Guangzhou Color Art Lighting Co., Ltd., before them, our reputation is good!
3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
First look at this lamp,.24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sunThe power supply comes from the generator or battery, and the mode of operation is to ignite by alternating current and direct current. In comparison with the power supply of the transformer, the method of alternating current ignition is better to save the cost and reduce the cost
Who knows how big transformers and lines the 36V transformer uses in lighting?
Depending on your load capacity, primary voltage, site reservation, etc.. For example, 3.6KW lighting, with 4KVA transformers, the primary side 380V with 2.5 square (copper wire) enough, two times the side of 25 square.
1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
To 30VA/ square meters, the transformer needs 30KVA, with two 120 square copper wire. Specific should be used to determine the total power of the lighting transformer.
Why should lighting transformers be used in factories and mines?
In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
Does the lighting work properly? Doesn't that power equipment start voltage unstable?
Power lines and lighting lines are connected to the same transformer, without affecting the use of a transformer power users, lighting and power are connected together.
Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.