Specification:
a.60W 1.8A LED driver, constant voltage.
b. Epoxy encapsulated, IP67. Suitable for outdoor lighting application.
c. Automated protection for over load and over temperature
d. Aluminum housing, good for heat dissipation
e. Cooling by free air convection.
f. Application: LED spotlight, LED downlight, LED panel light
Model | GLS-60-1800 | |
Voltage | 170-250V AC/90-130V AC | |
Frequency | 47-63 Hz | |
AC Current | 0.7A max@220V | |
Efficiency | 80% | |
DC Output | Voltage | 24V-36V |
Current | 1800mA | |
Rated Power | 60W | |
Protection | Over Load | 20% exceed in short time is allowed |
Short Circuit | Auto recovery | |
Over Voltaqge | ≤280V | |
Over Temperature | ≤85°C | |
Others | Store Temperature | - 40--85°C |
Wokring Temperature | - 25--55°C | |
Dimension/Weight | 180*69*43MM / 890g (Aluminium Housing) | |
Packing/Carton Size | 16PC/CTN 455×265×210mm | |
Input Cable | VDE H03VV-F 3G×0.75mm2 (330mm) | |
Output Cable | VDE H03VV-F 2×0.75mm2 (330mmx2) | |
Certificate | CE | Compliant to EN 60950-1:2006;
EN61000-6-3:2001; EN 55022:2006+A1:2007; EN61000-4-2/-3; EN61000-6-1:2001; EN55024:1998+A1:2000+A2:2003
|
RoHs | Free from lead, Cadmium, Mercury, Hexavalent
Chromium and/or PBB &PBDE
|
- Q:How many power illuminator can 5Kva 36V transformer drive?
- By formula: P=UI COSAThat is, the transformer capacity is S=UI=5KVAHow big is the COSA?. Look, what kind of illuminator do you use?. Usually take 0.8-0.9It can be calculated that P is about 4KW-4.5KW (general lighting)
- Q:Power and lighting transformers, lighting quality will be affected much?
- First look at this light. 24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sun. Its power comes from a generator or battery, and is lit by alternating current or direct current.
- Q:Why can't autotransformer be used as transformer for safety lighting?
- The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
- Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
- How many transformers should be used in the lighting of the 36V transformer, which should be chosen according to the power required. The greater the load (power), the greater the power to select the transformer.
- Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- The key is that the 220V terminals and 0 can not provide 1000VA capacity?
- Q:How many A leakage protection switches are used in 5000VA lighting transformers?
- Secondary current =5000VA/220=22A, you can select the 32A leakage protection switch.
- Q:Why is the two side of the lighting transformer grounded?
- The metal shell transformer grounding grounding protection is called: under normal circumstances is not charged, electrical metal and in the damaged insulation or other circumstances may be charged part (i.e. metal structure and insulation electrical parts part) and grounding wire connected to a reliable way to protect people.
- Q:Why is elevator lighting transformer installed?
- 9.4.5 well distribution shall comply with the following requirements:1 the elevator hoistway shall be dedicated to the elevator, and no equipment, cables and other devices related to the lift shall be installed in the hoistway.2 the well shall be provided with illumination, and the illumination shall not be less than 501x, and shall comply with the following requirements:
- Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
1. Manufacturer Overview |
|
---|---|
Location | Shenzhen, Guangdong, China (Mainland) |
Year Established | 2011 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia |
Company Certifications | ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Yantian |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Constant Current LED Driver 60 Watt 1.8A
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords