Constant Current LED Driver 60 Watt 1.8A
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specification:
a.60W 1.8A LED driver, constant voltage.
b. Epoxy encapsulated, IP67. Suitable for outdoor lighting application.
c. Automated protection for over load and over temperature
d. Aluminum housing, good for heat dissipation
e. Cooling by free air convection.
f. Application: LED spotlight, LED downlight, LED panel light
Model | GLS-60-1800 | |
Voltage | 170-250V AC/90-130V AC | |
Frequency | 47-63 Hz | |
AC Current | 0.7A max@220V | |
Efficiency | 80% | |
DC Output | Voltage | 24V-36V |
Current | 1800mA | |
Rated Power | 60W | |
Protection | Over Load | 20% exceed in short time is allowed |
Short Circuit | Auto recovery | |
Over Voltaqge | ≤280V | |
Over Temperature | ≤85°C | |
Others | Store Temperature | - 40--85°C |
Wokring Temperature | - 25--55°C | |
Dimension/Weight | 180*69*43MM / 890g (Aluminium Housing) | |
Packing/Carton Size | 16PC/CTN 455×265×210mm | |
Input Cable | VDE H03VV-F 3G×0.75mm2 (330mm) | |
Output Cable | VDE H03VV-F 2×0.75mm2 (330mmx2) | |
Certificate | CE | Compliant to EN 60950-1:2006;
EN61000-6-3:2001; EN 55022:2006+A1:2007; EN61000-4-2/-3; EN61000-6-1:2001; EN55024:1998+A1:2000+A2:2003
|
RoHs | Free from lead, Cadmium, Mercury, Hexavalent
Chromium and/or PBB &PBDE
|
- Q: Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q: Why is the two side of the lighting transformer grounded?
- Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
- Q: The difference between lighting transformers and control transformers
- A control transformer is a low voltage appliance, usually used as a power supply or part of a lighting for the control of electrical equipment such as machine tools. There are usually two different voltage outputs,
- Q: Why is elevator lighting transformer installed?
- 1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
- Q: Is the substation separate from the power and illumination transformer?
- There is only bus in the substation, and the station is connected with the transformer from the bus. If there is no electricity even in the bus, then the substation should not be considered active.
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- The transformer that power supply company manages, it is to supply motive power and illumination generally, namely the lighting transformer that does not have special illumination to illuminate. Units of their own transformers, is generally the case. The utility model has the advantages that the transformer and other equipment can be fully utilized, the efficiency is high, and the external power supply circuit does not need to be divided into power transmission lines and lighting circuits, and is simple and orderly, and the cost is low. As for the price of electricity, it is usually negotiated a power and lighting each percentage of the electricity to calculate and receive.
- Q: What's the function of the lighting transformer?
- In addition, can be rated power supply voltage of not more than 1000V AC circuit, as a machine tool and mechanical equipment control power, work lighting and signal light power supply, can also be used as a small power supply!
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- Because of the brightness of the 36V safety voltage lamp brightness in the overhaul work is not enough, so now the well lighting design should not be 36V, and replaced by 220V, and only need to add a leakage protector on it.
- Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- If you share a power line, you must calculate the current and select the appropriate wire to ensure normal pressure drop and safe use.
- Q: How to calculate the rated capacity of small transformers for lighting purposes?
- If the flow of large capacity motor starting current and welding machine, large current flows in a short period of time in the load even when the power equipment capacity can withstand current flow in a short time, but due to a voltage drop excitation electromagnetic switch relief, the motor can not start, damaged or the undesirable phenomenon of welding. Therefore, the voltage drop rate should be calculated as less than 10% of the supply voltage, as calculated below.
1. Manufacturer Overview
Location | Shenzhen, Guangdong, China (Mainland) |
Year Established | 2011 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Mid East; Western Europe; Central America; Northern Europe; South Asia |
Company Certifications | ROHS Test Report; Waterproof Power Supply CE-LVD; Waterproof Power Supply CE-EMC; CE-LVD |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Yantian |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese, Spanish, Japanese, Portuguese, German, French, Russian, Korean, Italian |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Constant Current LED Driver 60 Watt 1.8A
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 10 Pieces pc
- Supply Capability:
- 10,000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords