CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
30000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Introduction:

 

XLPE INSULATED POWER CABLE

COPPER(ALUMINMU)CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

 Cross-linked polyethylene insulated power cable do not only has excellent electric, mechanical proper-ties,but also has powerful resistance against chemical corrosion,heat resistance and environmental stress resistance. Its structure is simple,the long period operating temperature is +90°C. It is convenient to use and can be laid with no restriction of different level.

1.standards

The Products are mainly complying with IEC 60502 standard,  also can be produced according to OEM requirements and others standars, Such as BS Standard, DIN standard, ASTM standard, ETC.

 

2. voltage

Voltage grade is up to 35KV,

 

3. construction

copper or aluminum conductor

copper tape sheild

XLPE insulated

steel wire or steel tape or copper tape armoured

PVC sheath

 

Specification:

 

TYPE

 VOLTAGE

No.of cores

0.6/1kV

6/6kV, 6/10kV

8.7/15kV, 12/20kV, 18/30kV

19/33kV, 26/35kV

Mm²

COPPER/XLPE/PVC

1

1.5~800

25~800

35~1200

50~1200

AL/XLPE/PVC

2.5~1000

25~1000

35~1200

50~1200

COPPER/XLPE/SWA (STA,AWA)/PVC

10~1000

25~1000

35~1200

50~1200

COPPER/XLPE/PVC

3

1.5~400

25~400

35~400

50~400

AL/XLPE/PVC

2.5~400

25~400

35~400

50~400

AOPPER/XLPE/AWA (STA)/PVC

4~400

25~400

35~400

50~400

 

CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV

 

 

Q: I need a low profile extention to the exsiting power cable so it can run along the skirting to the mains socket.I was thinking of joining flex wire to the existing cable, wrapping the 3 cores with heatshrink, and then wrapping the whole thing with white insulation tape. the guy from maplin told me I could do this but then I''ve heard that this is a bad idea (and probably against UK safety regulations).
What I would do is make an extension up and just plug the heater into that. When you don't use the heater anymore use the extension for something else. Normally you need a Janus plug a normal plug and 2.5mm^2 three core flex. You can solder the wires and heat shrink it, just make sure the solder join is done well. If you just twist it together it might heat up and burn.
Q: My laptop works gr8, but the power cable when plugged into the machine is quite loose and just falls out sometimes which is very annoying. Has anyone with this laptop had the same problem and fixed it? if so how? an what do you think i can do to fix it?
contact dell maybe theyll help u
Q: what is a power cable?What does a power cable have to do with an xbox 360?Is a power cable the same thing as an AV cable?
The power cable is the Plug that goes from the Power outlet to your Xbox360. The AV cable is the cable going from your xbox 360 that splits into 3 plugs and plugs into your tv
Q: Hey! I bought a new sound system for my truck including 4 new speakers, a sub, a 5-channel amp, and I'm running all new wiring. So far I've got the 3 RCA cables ran, along with the blue remote turn-on wire along the right side of my truck. I plan to run the Power wire down the left side and then to my amp.I've heard that you put the power wire and RCA cables on different sides, which is what I've done, but is it ok for my speaker wires to be run beside or close to the power wire(4-gauge fyi)?For example, the right side speaker wires wont be near it, but the left side speaker wires will be...Will this cause any weird noise from my speakers?I don't have the names/etc of all my gear right in front of me, but if u rly need it, I will quot;add detailsfor you! Thanks!!
Separating the power the speaker wires is not as important in a car that uses DC voltage as it is in a home system that has AC voltage. It certainly doesn't hurt anything, tho.... If you do run them across each other, keep the intersection as close to a good right angle as possible. And, air is a very good insulator, so keeping some distance between the power the speaker wires is also very good.
Q: There are a few thin cables running from the power button on your computer onto the motherboard. What are these cables called?
Go to pc repair shop. And ash them.
Q: just asking if its atleast 5 feet.
The included cables are the standard 6' in length. There's nothing special about the PS3's power cord, so you can buy a longer one if you need it. The PS3 can also use standard HDMI and optical audio cables, so finding those in various lengths is easy. However if you need a longer PS3 AV cable (for composite, svideo or component video) you'll have to buy one online. They exist, or you can use a simple cable extension.
Q: Power cable inspection, how many meters should be sampled?
in the wide-linked pricing software GBQ40 to achieve, directly enter the corresponding quota, click on the quota below the" standard conversion ", the cable laying five core check , You can achieve the fixed sub-sub-multiplied by the coefficient of 13 For example: YJ - cross-linked polyethylene insulation (insulation) V - PVC jacket (outer jacket) did not mark the conductor material that is the default copper wire, if the aluminum wire should be YJLV4 * 70 + 1 * 35 core (Mm ^ 2) + Neutral core (indicated by "1") × Neutral core cross section (mm ^ 2) CT - Indicates the cable tray in the laying mode
Q: I am usng a ripspeed R2100 Amp JMB 1000W Sub speaker the amp has 2 25amp fuses attatched, but I do not know what fuse to use in the main audio power cable, I have been upto 40 amp it blew that, I dont know if I maybe have wire something wrong, can anyone help, thanks
you always take wat amp fuses you have in the amp and add them all together and thats the minimun fuse amp you can have in your power, your amp has 2 25amp fuses so you need at least a 50amp fuse on ur power wire, and if you have the lil fuses you cant go beyond 40 so youll have to go get a MAXI fuse block and get a 60amp fuse and you will b fine, you can find them on OKorder for less than 10bucks or at walmart for 15-20bucks, good luck
Q: I live in the uk
Laptops each have different power cords, because they have different connections to the laptop itself, so there's no one universal power cable. However, you can easily buy generic powercords for your specific laptop that are cheap. Just go to a site like Amazon and search for your laptop name.
Q: What is the difference between rubber insulation and paper insulated power cables?
When the cable is laid on the multi-layer bracket, the cables are arranged from top to bottom, the first layer is the high voltage cable, followed by the low voltage power cable. The control cable is placed on the lower part of the power cable. At the bottom of the instrument cable, when the low voltage power cable With the instrument cable in the same layer of laying, should be added partition isolation. Computer communication coaxial cable, full length are required to shield the use of closed trunking.

Send your message to us