butterfly valve DuplexSteel StandardSize: DN40-DN1200 Place of Origin: China (Mainland)

Ref Price:
Loading Port:
Payment Terms:
Min Order Qty:
1 pc
Supply Capability:
9999 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Standard or Nonstandard: Standard Structure: Butterfly Pressure: Low Pressure Power: Manual Material: Casting Temperature of Media: Normal Temperature Media: Water Port Size: DN40-DN1200 Place of Origin: China (Mainland) Wafer type: butterfly valve Packaging & Delivery

Packaging Details: Plactic bag+Paper cover+Plywood cases 

Delivery Detail: Within 20 days 


Wafer type lined butterfly valve 

1.Design standard:ISO,BS,API 



4.Center lined disc 

Wafer type lined butterfly valve 



Technical Data

DN40-DN1200mm PN1.0-1.6MPa

General Design:ISO 5752 / BS 5155 / API 609

Body: Cast Iron, Ductile Iron, Carbon Steel, Stainless Steel

Seat: EPDM, PTFE, NBR,Viton

Stem: Stainless Steel, Steel,

Disc: Ductile Iron with Nickel Coating,Ductile Iron with Nylon Coating, Stainless Stee 304/316l, Alu-Bronze,Duplex steel

Flange Connection:DIN,ANSI,JIS,BS


Product Features

Wafer type flanged body style fit between FF or RF flanges

PTFE bushing ensure the maximum shaft support and centralized alignment

360°polished disc assures positive on-off

Hard-Backed Cartridge seat or Edge-Boot seat

The pin,spline or square connection are all available

Universal ISO 5211 mounting pad.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Does the wet alarm valve group need to install the signal butterfly valve?
The wet alarm valve group shall be equipped with signal butterfly valve.The signal butterfly valve is generally installed in two parts: floor level, dry pipe, flow indicator front end, trunk pipe, wet alarm valve, front end.Floor level pipe installation is a function of the signal valve, when the floor spraying system needs repair, close the valve, open the end of the floor drain, emptying the water in the spray system, maintenance;
Q:Butterfly valve medium flow direction of the provisions of it?
The direction of the arrow on the valve body is cast, refers to the flow of media, users see the arrow, the arrow direction according to the logical and installation, this installation has become a habit, it is easy to accept the installation instructions, according to the national standard is not what error. But in the eccentric butterfly valve is installed so that sometimes there will be some problems, said the following example: according to the flow of eccentric butterfly valve with the medium flow consistent installation, tube medium is liquid, after the valve is closed, if the original direction of medium inlet pressure, reduced or zero, the export of medium reflux reflux, if senior supply, resulting in the high pressure medium, the pressure is greater than the inlet pressure, the valve will be subjected to reverse pressure, because the hard seal butterfly valve as a one-way valve so that the use is not conducive to sealing butterfly valve, and there will be leakage.
Q:Model specification for butterfly valves
1. classification by structure(1) Central sealed butterfly valve (2) single eccentric sealed butterfly valve (3) double eccentric sealed butterfly valve (4) three eccentric sealed butterfly valve2. by secret cover material classification(1) soft sealing butterfly valve. (2) metal hard sealing butterfly valve.3. classified by seal type(1) forced sealing butterfly valve (2) pressure sealed butterfly valve. (3) automatic sealing butterfly valve. The pressure of the seal is automatically generated by the pressure of the medium.4. classification by work pressure(1) vacuum butterfly valve. Butterfly valve with lower working pressure than standard atmosphere. (2) low pressure butterfly valve. Butterfly valve with nominal pressure PN<1.6MPa. (3) medium pressure butterfly valve. Butterfly valve with nominal pressure PN 2.5--6.4MPa. (4) high pressure butterfly valve. Nominal pressure PN is 10. 0--80.0MPa butterfly valve. (5) ultra high pressure butterfly valve. Butterfly valve with nominal pressure PN>100MPa.5. classification by operating temperature(1) high temperature butterfly valve. T>450 degrees C butterfly valve (2) medium temperature butterfly valve. 120 C6. classification by connection1 pairs of clip butterfly valve2, flange butterfly valve (3) lug butterfly valve. (4) welded butterfly valve.
Q:Are all vacuum EGR valve the same?
The first source, pages 20-22, lists all 9 basic types of EGR valves. Not all the types are vacuum operated, but check out #5 and #6 - they behave very differently from each other without a real live exhaust system connected to them.
Q:Electric butterfly valve (not take the lead) what do you mean?
Electric butterfly valve, as its name implies, consists of an electric actuator and butterfly valve, and the customer does not take the lead, that is, without the electric actuator, only the butterfly valve can be provided.
Q:What is an electric two position butterfly valve?
Answer for you:Shanghai Huquan electric valve manufacturer of electric double position butterfly valve this product is connected with the flange clamp. Material: cast iron, carbon steel, stainless steel, 304/316Product overviewElectric double position butterfly valve (soft seal) is suitable for temperature less than 200 DEG C, adjust the flux and closure of the role of the medium nominal pressure is less than 1.6MPa of food, medicine, chemical, petroleum, electric power, textile, papermaking, water supply and drainage, gas pipeline.main features1., the design is novel and reasonable, unique structure, light weight, fast opening and closing.2., small operation torque, easy operation, labor-saving and smart.3. can be installed in any location, easy maintenance.4., seals can be replaced, sealing performance is reliable, to achieve two-way sealing, zero leakage.5., sealing material aging resistance, corrosion resistance, long service life and so on.Electric double position butterfly valve adopts standardDesign standard: gb/T12238-1889Flange connection size: gb/T9113.1-2000; GB/T9115.1-2000; jb78Structure length: gb/T12221-1889Pressure test: gb/T13927-1992; jb/T9092-1999
Q:What's the difference between a butterfly valve and an eccentric butterfly valve? What is the difference in field applications?
Avoid friction and wear on the sealing surface!And, at the time of closing, and opening the opposite, there is a better sealing effect! Now generally use eccentric butterfly valve as the main. That's all I know! If there is any mistake, please forgive me!
Q:how to get a valve out of combustion chamber?
Your going to have to pull the heads.
Q:Pulmonary Valve Stenosis?
1761 - Pulmonary valvar or valvular stenosis is one of the more common forms of congenital heart malformations and it has been extensively studied since the original description of pulmonary valve stenosis by John Baptist Morgagni in 1761. 1888 - Tetralogy of Fallot, first characterized by Dr.Etienne Fallot in 1888, is present in about 3000 children born each year in the United States. It is a combination of four heart abnormalities. Dodrill and his colleagues employed it with success for the open correction of a stenotic pulmonary valve in October 1952.
Q:Does the pneumatic butterfly valve need electricity?
Definitely need control, so be sure to have electricity. You can control the switch on and off. If necessary, this valve can contact me.

1. Manufacturer Overview

Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range