• Aluminum Type MC  Branch, feeder and service power distribution under high ambient System 1
  • Aluminum Type MC  Branch, feeder and service power distribution under high ambient System 2
Aluminum Type MC  Branch, feeder and service power distribution under high ambient

Aluminum Type MC Branch, feeder and service power distribution under high ambient

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

APPLICATIONS suitable for use as follows:


  • Branch, feeder and service power distribution under high ambient temperatures in commercial, industrial, institutional, and multi-residential buildings

  • Power, lighting, control, and signal circuits

  • Fished or embedded in plaster

  • Concealed or exposed installations

  • Environmental air-handling spaces per NEC©300.22(c)

  • Places of Assembly per NEC®518.4 and theaters per NEC®520.5

  • As aerial cable on a messenger

  • Installation in cable tray and approved raceways

  • Under raised floors for information technology equipement conductors and cables per NEC®645.5(D)&645.(D)(2)

  • Class ⅠDiv.2, Class ⅡDiv.2,Class Ⅲ Div.1 Hazardous Locations

Joysense Aluminum Type MC Cable with tripele e® Aluminum Alloy Meets or exceeds the requirements of UL Standard 44,UL Standard 1569 for Type MC, ICEA S-95-658(NEMAWC70)for O-2000 V Nonshielded Cables, Federal Specification A-A59544(formerly J-C-30B),IEEE 1202(70,000BTU/hr) Vertical Cable Tray Flame Test, and the American Electrical CODE®. Joysense Aluminum Type MC Cable with triple e® Aluminum Alloy is listed for use in UL 1,2,and 3 Hour Through –Penetration Firestop Systems.


Joy Sense Aluminum Type MC Cable is constructed with Type XHHW-2 conductors rated 90℃ wet or dry, and a bare equipment grounding conductor. The Conductors are AA-8000 series Aluminum Alloy compact stranded. A binder tape is wrapped over the conductors with interlocked aluminum tape applied over the assembly. Aluminum interlocking armor is applied over the assembly. Refer to color chart for conductor color sequence.


  • UL Classified 1,2,and 3 Hour Through-Penetration Firestop Systems:W-J-3037,W-L-3110,W-L-3113,W-L-3117,W-L-3120,W-L-3121,W-L-3160,C-AJ-3115,C-AJ-3140,C-AJ-3142,C-AJ-3145,C-AJ-3173,C-AJ-3202,C-AJ-4065,C-AJ-4066,F-C-3038

  • Cable reverse wound on reel for ease of pulling and installation.When pulling from coils,pull from inside to ensure ease of installation

  • Anti-short bushings are not required for use with MC cable per the NEC® and UL


Q: I got a XFX radeon 5750 graphics card and after a lot of trouble I realized that I hadn't plugged in the 6 pin PCIe power cable, but I don't see any slots on my power supply, does anyone know how to fix this problem? I really don't wanna buy another power supply :(
Image provided in source. Basically, it is a power connector made specifically for pci-e graphics card, which comes from a power supply unit. A molex does not provide enough energy for modern graphics card, so the 6 pin was invented. There is an 8 pin pci-e power connector, which is an upgrade of the 6 pin, and it provides the graphics card with more energy. Most modern power supplies come with 6 pin connectors.
Q: A pair of Copper wire mains, each of 3.87 sq.cm cross section use to transmit the power, a distance of 915m for 10 hours a day, 80 kilo watt at 200 volts are taken from the mains, find power lost in cable per day at resistivity 1.7 micro ohm.cm.Note: Question is talking about A PAIR OF COPPER WIRE
Power loss per day is meaningless, I assume you mean energy loss per day, or power loss You have to calculate the resistance in the wire. Resistance of a wire in Ω R = ρL/A ρ is resistivity of the material in Ω-m L is length in meters A is cross-sectional area in m? A = πr?, r is radius of wire in m resistivity Cu 17.2e-9 Ω-m 3.87 cm? = 3.87 e-6 m? R = (2*915)(17.2e-9) / (3.87 e-6) = 8.13 ohms 80 kW at 200 volts is a current of 80000/200 = 400 amps You cannot put 400 amps through an 8 ohm resistance, as that requires a voltage of 3200 volts, which we don't have. So the premise of 80 kW is not possible. Perhaps you copied one of the numbers incorrectly. .
Q: Does the nvidia GT 520 require any power supply cables to be attached to it or do only the mid/higher end cards like HD 6870 require psu cables to be attached?Thanks
for low end cards, you dont need an additional 6 pin or 8 pin power cable for it. It is only for mid range and high range cards that need additional cable for it. For GT 520, you don't need it.
Q: Whether the weight of the power cable per meter is calculated
AC power is a two-phase exchange of the power system, itself is positive and negative exchange, the electromagnetic effect can almost count the daily life of the free radiation are more than this number, and can rest assured that the general life supplies, the larger electromagnetic radiation from the DC Of electrical supplies, which only need to pay more attention
Q: So I have a subwoofer in my trunk and was wondering if I could use the big power cables (coming from my battery) going into the amp (which is a JL Audio JX1000) to power some LED's that I want to install. My plan was to cut out a small section of the rubber sheath (or whatever you call it) from each power cable and put the clamps from a power inverter on them, then plug my LED's into the power inverter. After putting the clamps on I would use electrical tape or something to cover any exposed areas of the cable. Would this work? If it does work, which color clamp (black/red) would i put on which cable? One says quot;groundand is blue and the other says quot;+12VDCand is red. Also I have a toggle switch near the driver seat to cut the power from the amp so the LED's won't be left on after the car is turned off. Let me know if I'm leaving out any further information needed to answer my question.
You okorder /... Your power inverter, I am not sure what kind of cabling it will require for it to be powered properly as well. Ground is usually connected to Black. And +12v is usually Red.
Q: If you submerss the metal end of any kind of power cable like an extension cord in water will it work again?
It will if dried out over night. Placing it in direct sunlight will dry it faster. A hand held hair blower/dryer will work the best. Never use a wet cord for anything! This could lead to electric shock and/or death!
Q: Single single 10kV power cable with copper shield can wear steel pipe? What will be the impact?
. the first two said two cables, KW is KVV that PVC insulated jacket control cable. . the control cable for industrial and mining enterprises, energy and transportation sector, for the exchange rated voltage 450/750 volts below the control, protection lines and other occasions, the use of PVC insulated, PVC sheathed control cable. . the performance difference: the power cable in the main line of power systems used to transmit and distribute high-power power, control cable from the power system distribution point of electricity directly to a variety of electrical equipment, power equipment, power lines. The rated voltage of the power cable is generally 0.6 / 1kV and above, the control cable is mainly 450 / 750V. The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick.
Q: Copper core power cable models which several kinds
First, the total number of wire and cable products are thousands, applied in all walks of life
Q: i bought a video card off OKorder and i did everything but i don't know if i connect both of the cables to the power supply...i currently only connected one but do i do both…
You should really connect both, that way its getting the power it needs...though I ran a card on just one for a while and it was fine.
Q: Do I have to use a fuse for the power cable on an amplifier, if the amp is only a 350 watt amp?
It doesn't matter if its 350 watts or 35 watts. You need a fuse.