LV&MV, Al/Cu Conductor, Insulation/Sheath PVC/PE/XLPE, Shield CTS/, Armour SWA/DSTA/ATA, Power/ABC/ACSR/Control/Overhead cable
Power cable
1. Material: Cooper, Aluminum
2. Rated voltage: low and medium voltage
3. Wire identification: Red, yellow, blue, white, black
4. No. Of cores : Single core cable: from 1.5 mm2 to 800 mm2; Multi-core cable: from 1.5 mm2 to 400 mm2
5. Standard: Low voltage: IEC60502-1 Medium voltage :IEC60502-2 or other requirement.
6. Insulation: PVC, XLPE, PE
7. Sheath:PVC, PE, XLPE
8. Armor: Galvanized steel wires armouror Galvanized steel tape armour Aluminium Tape Armour/ Aluminium Wire Armour.
9. Application: Suitable for indoor, channel, conduit,underground,vertical well etc.
10. Nominal cross section area: from 1.5 mm2 to 800 mm2.
Aerial Bundle Cable Service Drop
1. 3x35+54.6+16 3x50+54.6+16 3x70+54.6+16 3x95+70+16 3x120+70+16 3x150+70+16 mm2
2.2x16mm2 2x25mm2 2x35mm2 2x50mm2 4x16mm2 4x25mm2 4x35mm2
3. Standard: ASTM ANSI, ICEA S-76-474, NFC 33-209 or other request.
Overhead electrical stranded cable (Bare Conductor)
1.Material: 1) Aluminum stranded wire and aluminum alloy stranded wire 2) Overhead stranded galvanized steel wire 3) Aluminum clad steel
2. Type: AAC, AAAC, ACSR, ACAR.
3. Standard: AAC: GB/T 1179-2008 IEC 61089 ASTM B232 BS 215 part1, DIN 48201-5 or other requirement.
AAAC:GB/T 1179-2008, IEC 61089, ASTM B 399 BS3242, DIN 48201-6 or other request.
ACSR : GB/T 1179-2008, IEC 61089, DIN48204, ASTM B232, BS215 PART 2or other request.
4.Application: These cables most widely used aerial line in aerial electric transmission lines and main product to form a power grid.
Aerial Insulated Cable
1. Material: Aluminium, copper
2. Type: LJ, LGJ, LGJF, JL, JLHA, JL/G, JLHA/G, JL/LHA, JL/LB, JLHA/LB, JG, JLB.
3. Rated Voltage: 0./1 kV, 10kV, 35kV.
4. No. of cores: 1, 2, 3, 4, 3+k(A), 3+k(B).
5. Standard: GB/T12527 GB/T14049 or other.
6. Insulation: PVC, PE, xlpe
7. Sheath:PVC, PE, XLPE
8. Application: applying in cable fixed aerial laying or used as wire leading into user's premises.
9. Nominal cross section area: from 10 mm2 to 710mm2.
Control Cable
1.Material: Cooper
2.Rated voltage: 300/500V, 450/750V, 0.6/1 kV.
3.No. Of cores : 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61
4.Standard: GB/T9330, IEC or customers' requirement.
5.Insulation: PVC, XLPE, PE
6.Sheath:PVC, PE, XLPE
7.Armor: Steel wire, Steel tape
8.Application: Suitable for chambers, tunnels and ducts, light-current control system and heavy-current magnetic interference region etc.
9.Nominal cross section area: 0.5~10mm²
PVC Insulated Electric Wires & Cables
1.Material: Annealed copper wires, bunched(class 5); Solid copper wire(class
2.Rated voltage: 300/500v and 450/750v
3.Wire identification: Red, yellow, blue, white, black
4.No. Of cores : single core, 2 cores,3 cores,4 cores, 5 cores
5.Standard: IEC 60227 or according to customers' requirement.
6.Insulation / Sheath : PVC
7.Application: Fixed wiring, house wire, building etc.
8.Nominal cross section area: from 0.25 to 240.
- Q: How high voltage armored power cable is grounded
- Copper braided wire for cable and shielding lead wire. Stripped of the core of the copper shield with the outer layer of the plastic belt, the shield copper belt polished smooth, with electric iron, solder braided copper braid were welded in the three core copper shield tape. And then use the emery cloth polished armored steel strip welding area, with a soft copper wire and copper shield belt tied with three armored steel, and then use electric iron, solder braided copper braided with armored steel belt. In the sealed ground to fill the braided wire with solder to form a moisture-proof section.
- Q: I have a VOX Valvetronix amp and my idiot older brother has misplaced the the power cord to it. Where is the best place to find said replacement as well as a guitar jack to plug into the amp itself since that seems to be missing as well. Thanks!
- Vox Ad30vt Amp
- Q: Why medium voltage power cable sometimes write 8.7 / 10kv sometimes written in 8.7 / 15kv where the difference
- . 1.8.7 / 10kV U value of 10KV, which can withstand the maximum voltage of 12KV8.7 / 15kV U value of 15KV, which can withstand the maximum voltage of 17.5KV2.8.7 / 10kV is 10KV system in the first Class II cable (fault time can be greater than 1 minute) 8.7 / 15kV is the first type of cable in the 15KV system (failure time is not more than 1 minute) 3.U0 / UU0 - conductor and insulation shield between the voltage U - the The voltage between the conductors is two, the cable is usually a few or several groups of wires [at least two] stranded from the rope similar to the cable, each group of wires insulated from each other, and often around a central twist The entire outer package has a highly insulated cover. Multiple in the air or in the ground, underwater, for telecommunications or power transmission.
- Q: I have a feeling my power quot;brickis faulty and need to find a replacement, hopwever, none of the high street retailers quot;Game, Gamestation, HMV, Argosseem to stock them.
- u can contact microsoft talk to them on teh phone for 5-10mins and theyll giv u a free one
- Q: if we provide power through power cable will there be need of extra capacitor near load?
- Yes, if you are talking about a bypass capacitor. Electronics always requires a bypass capacitor near the circuit/IC. Having one at the end of a cable means the cable inductance is in series, and the impedance seen by the IC power supply leads is inductive and high instead of the needed low impedance that a local bypass cap provides.
- Q: If you submerss the metal end of any kind of power cable like an extension cord in water will it work again?
- It will if dried out over night. Placing it in direct sunlight will dry it faster. A hand held hair blower/dryer will work the best. Never use a wet cord for anything! This could lead to electric shock and/or death!
- Q: Trying to troubleshoot my computer I have been unplugging and replugging wires. After a while of looking around I have found that the ATX power connector is missing a part of the pin. Now my computer is unable to boot. Is there a way to fix it. Or am I stuck going to get to a new computer.
- Im confused, which cable is this? If this is a home-built PC RMA your power supply but if it's a HP/Dell/Whatever then call them for support and/or warranty info.
- Q: It's not the original power cable but it's going to my current DVR.
- The cable will work just fine.
- Q: I have a MSI K7 Motherboard... it has a SATA power cable but no data cable. Which kind of confuses me. Please help. Thanks =)
- A word of advice ... if you plan to install Windows on this new drive you will need to prepare a driver disk for the SATA adapter. During the first stages of Windows install it will ask you to press F6 to install any third party drivers for RAID or SCSI .... without it Windows may not detect the adapter hence the SATA drive. regards, Philip T
- Q: 10KV cable is directly from the nearest substation led to the power distribution room, how some people say that from the transformer can not understand what the meaning of more
- Low-voltage power cable, also known as: low-voltage power cable. The voltage rating is 0.6 / 1KV. National Standard No .: GB / T-2008. The voltage rating of the control cable is 450 / 750V. National Standard No .: GB / T9330-2008. The voltage rating of these two cables, the country has a clear standard. Can not be changed.
Send your message to us
Al / Cu Conductor , PVC cable cable,Power Cables
- Loading Port:
- China main port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords