AGM Battery the Eos Series Battery  Eos-800

AGM Battery the Eos Series Battery Eos-800

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 unit
Supply Capability:
200000 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

AGM Battery the Eos Series Introduction


                                 

The Eos range products are designed as standby power for communication, power, military and broadcast and television system. Elegant design with high energy density, latest improved technology are adopted in this series,design life is 15+ years.

The Eos range batteries are ensured the quality with NARADA's QA system according to the ISO9001 standard.AGM Battery the Eos Series Battery  Eos-800

AGM Battery the Eos Series Technical Features


  • AGM technology is applied.

  • 15+ years design life under floating application and cycle life is above 1200 at 80% DOD under temperature 25oC.

  • Reliable seal performance, no acid spillage, recombination efficiency reach 99.9%

  • Initial capacity above 100%, the remaining capacity above 94% after storage for 3 months (25oC)

  • low float charge voltage. design (2.25V/cell, 25oC), extremely consistent float charge voltage

  • Flexible connectors and convenient installation

 

AGM Battery the Eos Series Battery  Eos-800

AGM Battery the Eos Series Battery  Eos-800

Type:

  Eos-800

Voltage:

  2V

Nominal Capacity:

  800Ah(C10)  800Ah(10 hours rate:)

Length:

  154mm

Width:

  229mm

Height:

  555mm

Height  with termial:

  566mm

Weight:

  52Kg

 

AGM Battery the Eos Series Compliant Standards

  • IEC60896-21/22

  • BS6290 part 4

  • Telcordia SR4228

  • Eurobat guide

  • UL

  • Manufactured under system ISO9001(TUV)

AGM Battery the Eos Series Battery Installation Compliant with:

  • EN 50272-2 or local equivalents

AGM Battery the Eos Series Main Applications

  • Telecommunications

  • Uninterruptible power supply (UPS)

  • Other applications to provide integrated stored energy system

AGM Battery the Eos Series Products Characteristics:

  • Recommended float charge voltage for 2V battery: 2.25Vpc at 77oF(25oC)

  • Self discharge rate :< 2% per month at 77oF(25oC)

  • Design life: 15+ years at 77oF(25oC)

  • Shelf life: 6 months at 68oF(20oC)

  • Valve regulated system, no water addition needed

FAQ

What is a AGM (Absorbed Glass Mat )Battery?

The newer type of sealed nonspillable maintenance free valve regulated battery uses "Absorbed Glass Mats", or AGM separators between the plates. This is a very fine fiber Boron-Silicate glass mat. These type of batteries have all the advantages of gelled, but can take much more abuse. These are also called "starved electrolyte.Ąą Just like the Gel batteries, the AGM Battery will not leak acid if broken.

What are the advantages of the AGM battery?

The advantages of AGM batteries are no maintenance, sealed against fumes, hydrogen, leakage, or non-spilling even if they are broken, and can survive most freezes. AGM batteries are "recombinant" ¨C which means the Oxygen and Hydrogen recombine inside the battery. These use gas phase transfer of oxygen to the negative plates to recombine them back into water while charging and prevent the loss of water through electrolysis. The recombining is typically 99+% efficient, so almost no water is lost. Charging voltages for most AGM batteries are the same as for a standard type battery so there is no need for special charging adjustments or problems with incompatible chargers or charge controls. Since the internal resistance is extremely low, there is almost no heating of the battery even under heavy charge and discharge currents. AGM batteries have a very low self-discharge rate (from 1% to 3% per month). So they can sit in storage for much longer periods without charging. The plates in AGM's are tightly packed and rigidly mounted, and will withstand shock and vibration better than any standard battery.


 

Q: How is the capacity of the battery defined?
100AH capacity of the battery, fully charged after the 100A current discharge can be an hour to put the power finished. 50A current is 2 hours put away! 20A is 5 hours! Of course this is the theoretical value, in fact it is impossible to have a constant current discharge.
Q: What is the difference between a maintenance-free battery and a conventional battery?
Different materials will produce a different phenomenon: the traditional battery in the course of the use of the phenomenon of liquid reduction occurs, because the antimony on the grid will pollute the sponge on the negative plate of pure lead, weakened after the full charge of the battery Electromotive force, resulting in excessive decomposition of water, a large number of oxygen and hydrogen, respectively, from the positive and negative plates to escape, so that the electrolyte reduced. With calcium instead of antimony, you can change the fully charged battery back electromotive force, reduce the overcharge current, liquid gasification rate decreases, thereby reducing the loss of electrolyte.
Q: What are the technical parameters of the battery?
Battery capacity is defined as ∫ t0tdt, theoretically t can be infinite, but in fact when the battery discharge is lower than the termination voltage continues to discharge, which may damage the battery, so t value is limited, the battery industry, in hours (h) Battery sustainable discharge time, feel the C24, C20, C10, C8, C3, C1 and other nominal capacity value.
Q: How to determine the battery is good or bad?
If less than 9V but the pointer is in a certain value does not move that the battery is in a state of loss, need to add charge.
Q: How to deal with waste batteries?
The old battery is ground and then sent to the furnace for heating, then the volatile mercury can be extracted, the temperature is higher when the zinc is also evaporated, it is also precious metals. Iron and manganese fusion after the steel to become the required ferromanganese alloy.
Q: How should the battery be well maintained?
So the proposed owners if the vehicle long-term stop, but also 2 to 3 months for the battery for a charge.
Q: 80ah how much battery storage capacity?
0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
Q: The role of the battery?
Battery is a kind of battery, its role is to be able to save the limited power, in the right place to make 6v4ah emergency light battery. Its working principle is to convert chemical energy into electricity.
Q: What is a maintenanceable battery?
Maintenance-free battery due to its own structure on the advantages of electrolyte consumption is very small, in the life of the basic need not add distilled water.
Q: Lead-acid battery how to maintain?
Along the battery cover on the exhaust hole, open the battery cover plate, some of the battery cover is APS adhesive, and some batteries are buckle connection, pay attention to open the cover when the cover plate The At this time you can see the six exhaust raft rubber cap.

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords