XLPE Copper/Insulated/Copper/Rubber Cable
Specifications
1 IEC, ASTM, DIN, BS standard
2 ISO,CCC,CB certification
3 Response within 12 hours
4 Free Sample
5 Factory direct sale
POWER CABLE
XLPE INSULATED POWER CABLE
COPPER(ALUMINMU)CONDUCTOR XLPE INSULATED PVC SHEATHED POWER CABLE RATED VOLTAGE UP TO 35KV
Brief introduction about XLPE Insulated Power cable
Cross-linked polyethylene insulated power cable do not only has excellent electric, mechanical proper-ties,but also has powerful resistance against chemical corrosion,heat resistance and environmental stress resistance. Its structure is simple,the long period operating temperature is +90°C. It is convenient to use and can be laid with no restriction of different level.
APPLICATION
XLPE insulated power cables has a number of advantages over paper insulated and PVC insulated cable.XLPE cable has high electric strength, mechanical strength,high-ageing resisting,environmental stress resisting anti-chemical corrossion,and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide,silance and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke low-halogen,low-smoke halogen free,and non-smoke nonhalogenated and three slasses of A,B,C.
We can produce the cables as per GN, IEC,BS,VDE, AS/NZS,ICEA,JIS.
TYPE | VOLTAGE | ||||
No.of cores | 0.6/1kV | 6/6kV, 6/10kV | 8.7/15kV, 12/20kV, 18/30kV | 19/33kV, 26/35kV | |
Mm² | |||||
COPPER/XLPE/PVC | 1 | 1.5~800 | 25~800 | 35~1200 | 50~1200 |
AL/XLPE/PVC | 2.5~1000 | 25~1000 | 35~1200 | 50~1200 | |
COPPER/XLPE/SWA (STA,AWA)/PVC | 10~1000 | 25~1000 | 35~1200 | 50~1200 | |
COPPER/XLPE/PVC | 3 | 1.5~400 | 25~400 | 35~400 | 50~400 |
AL/XLPE/PVC | 2.5~400 | 25~400 | 35~400 | 50~400 | |
AOPPER/XLPE/AWA (STA)/PVC | 4~400 | 25~400 | 35~400 | 50~400 |
FAQ
Q: Why should you choose us:
A: 1. More than 10 years experience in this industry
2. 100,000 tons exporting per month
3. Professional foreign trade tea
4. OEM&ODM capacity
5. High quality assured & competitive price
6. Try our best to meet your needs & save your budget
7. Very popular in Southeast Asia, Africa, Mid-East and South America etc.
8. VIP membership system, first time customers and long-term cooperation customers can get extra discount on some products.
Picture
- Q:Its a Extreme power plus 700w the U.S.A and Canadian type.
- It depends on where you will be using it. The adapters' female end will accept U.S. power cords. However, the male end will not be usable in U.S. electrical receptacles. If you are planning to travel to Australia or live there, then you are golden. However, if you live in the United Stated, then it is useless without an additional adapter. I am Comp TIA and A+ certified with 27 years experience.
- Q:When I went to go set it up, everything is ps3 except the power cable. You know on the side where it connects to the ps3? Well its supposed to be round on both sides. Well ours is round and square. Can i shave the square one or will it not work?
- No, you can use the power cable for a computer on the PS3. It is a standard shape and can be purchased from any good computer shop. The PS2 uses a transformer and the pin alignment is different. Just get a proper cable, they are really cheap anyway.
- Q:So I was trying to run wiring for a 220 outlet and I hit a lower leg with the metal cable snake, now a bunch of outlets loose power for a minute or two ever so often, 20 min give or take. What can be the cause? Only the top breaker tripped. How can this be repaired. Please help.
- Would I be right in thinking you sort of tripped on flexible metal conduit in which electric cables run and now the power is intermittent and trips the breaker? I would start by isolating the circuit so it is no longer live and checking the connections at each end of the cable run because any strain on the conduit could have tugged wires out of their terminals. I'd make sure that all the connections were tight and the wires properly anchored and also that each wire is in the correct terminal. I once made a mistake when replacing a socket outlet because the terminals in the new one were the exact opposite of the old one. Luckily, I found it straight away when I tested the circuit. If the connections all look good, I'd check the continuity along each of the cables. It is inconceivable that the cables inside the metal conduit were damaged as they should be continuous cable runs with no joins. The continuity test will tell you if any cable is no longer continuous, but I'd be very surprised as long as the original installation was done properly to code (or wiring regulations in the UK). Obviously, before you start checking the cables, you would unplug or disconnect everything that is connected to them. If the fault only happens when some sort of machine or appliance is connected, then it suggests the fault is with the appliance or machine and not the wiring. A 20 minute cycle of faults makes we wonder whether there is a fridge or a freezer connected the circuit. If so, I'd get it checked for faults and check that the power connection to it is correctly wired. I am not an electrician, just an experienced home owner, so please double check anything I've said. Good luck.
- Q:HiIs it advisable to run 110VAC cable from the sub stationa and 110VAC cable from generator (clean) in the same conduit ; one of them for lighting and the other for CCTV; the concern is if the one for lighting is not clean (not consisting of a pure sine wave or carrying interference) would that effect the power line of the CCTV and has an effect on the picture? even though both are 110VAC.the installation is over seas where the power from the station is not consistence.
- if all the wires are rated the same you won't have a problem, but make sure you don't share the neutral with both circuits or you could get some interference. Run separate neutrals for each circuit and make sure your CCTV is on a dedicated circuit
- Q:Need the cable you plug into your outlet and it's plugged into the back of your power supply on your computer. My computer is for gaming and is very modern so I need one that wont melt and can handle everything. Anyone know of anywebsites that I can order a high quality one from?
- If you have a problem with your power cords melting, then the problem isn't the cord, it's your electrical wiring!
- Q:I asked before about installation of power and control cable in the same conduit .. I think it is not a good practice.. I want to ask about installing 2 power cable each 480V in the same conduit ..Also I want to know if it is mentioned in any standard like NECthx
- You can as long as every cable in the raceway is insulated at least for the maximum voltage in the raceway. NEC 300.3 (C) (1). You also need to consider raceway fill limits, and ampacity derating for 4 or more current carrying conductors.
- Q:Whenever I unplug the power cable, the laptop starts to lag, bad, and yes I do have a fully charged battery. This has been happening ever since I got the thing, and no it has nothing to do with the battery, and no matter how many times I re-plug the cable and take it out again, or just leave it in, it continues to lag. The only time it stops is when I reboot, at least until I unplug it again. Also, it has nothing to do with the performance battery plan. Any ideas? This is really annoying.
- Do you mean lag as in a slow OS. Well- Where is your SPEEDSTEP set at in your BIOS? You may have 3 or 2 settings which ARE affected when your Cable Power is removed it will go to a Bit Slower Processor Speed to prolong the battery. If after you change the settings in BIOS and it does this again, its likely need to be sent back for repair under Warranty as this is NOT Normal...
- Q:Hi, my computer power supply does not have a PCI-E 6 pin power cable for my graphics card, so therefore I found a 2 (4 pin molex) to 1 PCI-E power cable Y adapter.
- Motherboard doesn't provide that connector for the video card. the power supply does. Take the side panel off and see if it has one. Can always use a 4/6pin adaptor. Most retail cards come with one. Just make sure you have enough watts and +12V amps on the PSU to run the new card. A lot of video card upgrades require an upgrade for the power supply as well.
- Q:Like from a computer monitor?or a pc power cable?would a generic power cable work for it or would it like, blow the brick up lol?
- The third is a floor, you ought to attempt and discover an adapter which will settle for a three prong plug. It' s no longer needed, yet its stable to have. Your laptop ought to settle for the voltage, look on the potential adapter project inline with the twine and seem to be certain what its voltage score is. it ought to have a gaggle of written stuff , between the lines will say enter AC one hundred-240v a million.5A or something comparable. If it would not study one hundred-240 yet rather reads 110v, then do no longer plug it in, the 2nd you are attempting this is going to smash. my pals plugged in an xbox to a 220 volt gadget, they did no longer even turn it on, something exploded interior very just about at modern.
- Q:where can i put my amp power cable through my bulk head in my 1999 1.8L 16 valve ford mondeo lx?
- Find the main harness going through the fire wall and follow it
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
XLPE Copper/Insulated/Copper/Rubber Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords