Water Pump Serie Submersible Sewage Pumps Made In China

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 set
Supply Capability:
100 set/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Specifications

1)High performance
2)Mechanical seal
3)Cast iron impeller or bronze impeller
4)Lower vibration water pump
5)Large flow

2.Packaging & Delivery

Packaging Detail:

export wooden cases

Delivery Detail:

within 30 days once receipt of 30% T/T prepayment

BPO Irrigation Centrifugal Split Water Pump

3.FEATURES

BPO series single-stage double-suction open type centrifugal pump self-researched by the Company after absorbed advanced technology of similar products and combined application requirement of various customers. The series pump adopts excellent hydraulic model, wider type spectrum and better structure. Pump casing is produced by special machine tool, which ensures concentricity among shaft bearing, shaft and pump case, and provides better reliability and maintainability. Apply to municipal water supply and drainage, water circulation of air conditioner, agricultural hydraulic engineering, such as irrigation, drain flooded fields etc., industrial water supply system, firefighting system, water supply and drainage of
heating system, transportation of clean water

4. OPERATING CONDITION

a)Rotate speed: 2950r/min, 1480 r/min, 980 r/min, 730 r/min
b)Flow range: 64.4~9810m3/h
c)Delivery lift: =200m
d)Medium temperature: =80 ,
e)product adopting special materials: -20 ~120
f)Ambient temperature: Lower than 40
g)Operating pressure up to achieves 2.5MPa

5. MATERIAL 

a)Pump casing: Cast iron or magnesium iron
b)Pump cover: Cast iron or magnesium iron
c)Impeller: Cast iron, magnesium iron or tin bronze
d)Sealing ring: Cast iron or tin bronze
e)Pump shaft: 45# steel plated with chrome
f)Dynamic and static mechanical sea: Hard carbide, graphite
g)Configuring other material according to requirement is allowable

Rated flow

10(m3/h)

Rated head

26m

Rated power

1.5Kw

Voltage

220V

Rated Current

7.2A

Rated speed

2860r/min

Discharge diameter

50mm

6.Conditions of use

Pumps used in the following conditions should be continuously to work properly: 
1. For water pumps suitable medium, medium temperature shall not exceed + 40°C
2. The medium PH value between 6.5 ~ 8.5 
3. The volume of medium containing solid impurity is less than 0.1%, the size is not more than 0.2 mm 
4. The power frequency 50 hz, voltage for single-phase 220 v, 380 v, three-phase voltage fluctuation range for rating of 0.9 to 1.1 times 
5. Diving depth of no more than 5 m, is not suitable for irrigation and drainage of sewage and chemicals.

Water Pump  Serie Submersible Sewage Pumps Made In China

Water Pump  Serie Submersible Sewage Pumps Made In China


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the water pump population pre rotation, what harm?
Is the entrance of water flow in the formation of complex turbulent flow, flow direction, shock, vibration, easy to damage the front entrance device, such as vane impeller, shaft sleeve, sealing element. In order to prevent the emergence of the pre swirl phenomenon, usually the design will inlet than outlet diameter, try to make the entrance flow in laminar flow, according to streamline our design, in order to protect the safety and prolong the service life of equipment.
Q:What does "ETA" mean in the selection of pumps?
Water pump selection table "ETA" is the meaning of efficiency. NPSH refers to the pump's cavitation margin.ETA is abbreviated as "efficient ratio", and Chinese means "water efficiency". The efficiency of the pump here is generally referred to as the efficiency of the pump design point because the actual efficiency of the pump varies with the pump operating conditions. The efficiency of the ETA can also be interpreted as the efficiency of the pump at the rated lift (or rated flow).
Q:About water pump selection
0.1MPa 1, according to the water pressure of the hydrant, dry season difference 17m geometric head for 17m, the pipeline resistance calculated according to 10%~20% 1.7~3.4m, from 3m, so the pump head should be 17+3+10=30m, considering that this is the dry season conditions, when the water level elevation is lower than 17m when the actual demand of low lift in 30m, it is not recommended to 35m head to head design, 30m under various conditions are enough (the actual operation of pump lift by lift device, so if the head is too high may lead to the actual use of pump bias conditions, and low lift and large flow operation, the flow of super power) selection of I don't know your personal needs, can not make a judgment, suggestion the flow rate and pipe diameter according to the economic flow rate of 2.5m/l is about to take it.2, from the operation of the pump, it is best to water intrusion, is higher than the pump center line, so it is best to get the pump installed under the negative on the second floor, if you can not meet the high water pump and the center line, there are three choices in the selection of a pump: 1, submersible pump (by landlord excluded); 2: the ordinary centrifugal pump + water diversion device (water diversion valve then available irrigation water or vacuum diversion device, this approach might not be used, and irrigation valve trouble, valve is broken with it, such a small pump vacuum water cost is too high); 3: self suction pump. Recommendations may consider self suction pump, self-priming pump is also divided into no sealed automatic control self-priming pump and general cantilever self-priming pump both, but the installation height is still lower, the better, because the lower the water level of the entrance, the more likely to suck water.
Q:Yang Chengtai big, the pump power is too small, the water pump will be bad?
Related to water pump structure, when the pump head is higher than the rated pump head, the current will increase, the water discharged from the pump impeller, back to the inlet of water from between the impeller and the casing exceeds the rated value, if it is a high lift pump, clearance between the impeller and the casing is small, the water pump current increases with increasing lift, current too much faster than the rated value, the motor will burn; if it is a low lift pump design, when the clearance between the impeller and the casing of the strict requirements, and even some of the water pump, the outlet is blocked, the pump will not burn. The drinking water pump used on the table, generally used non-toxic latex diaphragm pump, the head is too much, will damage the diaphragm part, the motor because the circuit has protection, the motor is not easy to damage. Generally do not risk good, according to the actual situation, select the appropriate lift, suction pump.Yang Chengtai large! If the pump power is too small! The pump will break! But not necessarily bad, mainly determined by the pump structure.
Q:How large is the starting current for a 1.5 kW submersible pump?
1KW about 2 current, so the rated current is about 3A, and the starting current is usually 3-8 of the rated current, that is 9-24A.
Q:Pump adapter joint net outside tube, what is the principle?
First, the working principle:Fire pump adapter is connected with the public security fire department fire engine or motor fire pump fire water transport through the fire pump adapter interface fire water supply pipeline to the buildings, the fire hydrant indoor get sufficient pressure to solve the problem of water shortage and other difficulties or because of fire water supply pipeline inside the building due to low water pressure caused by the fire fighting for high-rise building, indoor use and normal operation of fire pumps and intermittent water supply situation in. The installation types include floor type, underground type and wall type.A brief introduction to the two, pump adapter:When a fire occurs, the fire engine pump can quickly and conveniently through the interface and building the adapter in the fire fighting equipment is connected, and the water pressure, so the indoor fire equipment pressure with sufficient water to extinguish, different floors of fire, effectively solves the problem of building fires, fire fighting because of difficulties or indoor fire fighting equipment due to lack of adequate water pressure to the fire.
Q:What are the conditions for the series and parallel connection of the pumps?
Parallel pumps: the pump is required to lift the same. This effect is to increase traffic.Pumps in series: requirements are similar to the flow of water pumps. This allows you to increase the total head and recommend adding small pressure tanks during the series connection.
Q:The diving pump in the aquarium stops and stops on the goldfish
Submersible pump is used as if you push the pump filtration should be open for 24 hours, so the water circulation process, continuously into the fresh air to increase the oxygen content of water bodies two, filter on the filter of the continuous cleaning system to maintain water make nitrification safe and clean, the water can be fully introduced the content of nitrification ammonia water, let the fish live healthy and strong resistance, good activity, three appropriate water flow on the long time to keep fish, turn off and the formation of water to fish is always in a state of tension and decreased immunity antifeedant or death. Four, frequently start the pump, easy to cause damage to the motor coil, reduce pump life, so according to the above, if you are using submersible pump as a filter to promote, I suggest you open 24 hours.
Q:What are the commonly used tools for repairing water pumps?
This universal table is necessary, there is an insulation resistance meter, with some 8 six angle screws, as well as a common pump mechanical seal, you can also enter some of the water pump cable
Q:Horizontal pumps, vertical pumps, which kind of expensive?
Not expensive, depending on the specific model, in fact, the vertical pump is not much

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range