Horizontal Single Phase SVC AC Voltage Regulator 5KVA

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1 Piece pc
Supply Capability:
2000 Pieces per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Power

0.5kVA-10kVA(Horizontal)

5kVA-60kVA(Vertical)

Single phase input voltage

70V-130V and 160V-250V

160V-250V

Single phase output voltage

220V and 110V

220V

Accuracy of voltage stabilization

220V±3% 110±6%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

Three Phase Four-wire AC Voltage Regulator

Power

1.5kVA-60kVA

Three Phase Input Voltage

Phase voltage 160V-250V;Wire viltage 277V-430V

Three Phase Output Voltage

Phase voltage 220V;Wire viltage 380V

Accuracy of voltage stabilization

2-5%

Frequency

50Hz/60Hz

Adjustable time

1s(When input voltage has a charge of 10%)

Waveform distortion

No additional waveform distortion

Efficiency

>90%

Load power factor

0.8

Working environment

Tenperature:-5--+40   Humidity:<90%

Dielectric strength

1500V/1min

Insulation resistance

≥2MΩ

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
First look at this lamp,.24V100W, this specification is common in the headlights of large trucks, filled with inert gas, known as the small sunThe power supply comes from the generator or battery, and the mode of operation is to ignite by alternating current and direct current. In comparison with the power supply of the transformer, the method of alternating current ignition is better to save the cost and reduce the cost
Q:What type of low voltage transformer should be adopted for safety lighting power supply?
Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
Q:Why is elevator lighting transformer installed?
Is that the kind of 220V change 36V ah, if it is that kind of thing, I think it should be for security reasons. After all, 36V is a safe voltage. The damage to humans is slightly smaller than that of 220V.
Q:Can the 500 volt lighting transformer be changed into an electric welder?
500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
You must know the quantity and power of the lamp to determine the transformer
Q:Our power lines and lighting lines are connected to the same transformer. Is there any effect?
Connection mode:N circuit breaker is caused by breaker of outlet line of transformer main cabinet.The branch circuit breaker divides the power, the electricity and the lighting power.
Q:How many power illuminator can 5Kva 36V transformer drive?
Of course, if you want to bring more is not impossible, but depends on the working conditions, the actual power = nominal power, short time use (to ensure that the transformer temperature rise is not too high) is also available
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Generally, the power of the transformer is the apparent power, and the light bulb is the active power, and the power matching is taken into account.
Q:How many 40W bulbs can be brought into the 1000VA lighting transformer?
Connect 220V method, FireWire 220V terminal, zero line 0 terminal, 380V terminal is not connected.Connect 380V method, A phase 380V terminal, B phase 0 terminal, 220V terminal is not connected.
Q:Why is the two side of the lighting transformer grounded?
Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
We have set up stable trading cooperation with customers from the Middle East, South Africa, North America, Europe and other areas worldwide. We gain a good reputation among customers and lay solid foundation for our development. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Shanghai, China
Year Established 2008
Annual Output Value US$50 Million - US$100 Million
Main Markets South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Central America
Northern Europe
Southern Europe
South Asia
Domestic Market
Company Certifications CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shanghai Port,Ningbo Port,Guangzhou Port
Export Percentage 81% - 90%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese, Spanish, Arabic, French, Russian
b)Factory Information  
Factory Size: 3,000-5,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average