Online UPS Power Supply 1KVA, 2KVA,3KVA

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
5 Units pc
Supply Capability:
5000 Units per Month pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

Application:

 

T Series 1KVA~3KVA High frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.

 

Key Features:

 

LED Indicators display Detailed Real-Time UPS Status and parameters.

 

Set Output Voltage, Frequency parameter and bypass function on the display.

 

Advanced MCU microprocessor control technology, ensure long life reliability. 

 

Wide input voltage range, Zero transfer time

 

Excellent Protection against over voltage, over load, over current, over charge and so on.

 

Input L and N lines reverse wiring detection, Auto start when AC back.

 

DC start function, Input PFC revise function.

 

Humanization bypass output, can be adjustable.

 

Smart RS232 communication with monitoring software

 

Intelligent slot available for AS-400 Dry contact and SNMP card Remote control

 

Available to work with generators.

 

Lightning, surge, short circuit, Network/fax/modem surge protection

 

 

Basic tech datasheet

 

UPS Model

EX1K

T1K

EX2K

T2K

EX3K

T3K

Capacity

1000VA/700W

2000VA/1400W

3000VA/2100W

Input

Voltage

(115~300) VAC

Frequency

46~54Hz/56~64Hz (Adjustable via LCD panel)

Output

Voltage

220/230/240 (1±1%) VAC (Adjustable via LCD panel)

Frequency

50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode:50Hz (1±0.2%) 60Hz AC Mode:Follow AC Mode(AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%)

Output Wave Form

Sine Wave

Back-up Time

Full Load

≥5′

≥9′

 

≥5′

 

Half Load

≥14′

≥21′

≥15′

Battery Nominal DC Voltage

36VDC

96VDC

Transfer Time

0ms

Overload Capacity

110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms

Communications

RS-232+Intelligent Slot

Environment

Temperature

             0C~40C

Humidity

             15%~90%

Dimensions (W*D*H)mm

400*145*220

460*192*348

460*392*348

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
If there is no painting can be used with a diode symbol file (measuring probe connected to the capacitor to hear a sound if the table does not ring at the table and then the general display is 1, then the pen on the emergence of the phenomenon that the capacitance is still good. If one table has been ringing that received the capacitor capacitor breakdown is broken)
Q:What type of low voltage transformer should be adopted for safety lighting power supply?
In general, indoor transformers are used in general practice
Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
If the transformer is not calculated, the loss is the same. If the calculation is the latter, save electricity.
Q:Is the substation separate from the power and illumination transformer?
The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
Q:How many power illuminator can 5Kva 36V transformer drive?
By formula: P=UI COSAThat is, the transformer capacity is S=UI=5KVAHow big is the COSA?. Look, what kind of illuminator do you use?. Usually take 0.8-0.9It can be calculated that P is about 4KW-4.5KW (general lighting)
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
If you share a power line, you must calculate the current and select the appropriate wire to ensure normal pressure drop and safe use.
Q:How many 40W bulbs can be brought into the 1000VA lighting transformer?
The key is that the 220V terminals and 0 can not provide 1000VA capacity?
Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
The sectional area of the wire can be calculated according to the electric power formula. The current required by the wire is calculated, and then the reference to the national standard "500 volt copper core insulated wire, long term continuous load allowable ampacity meter" is selected.
Q:Why can't autotransformer be used as transformer for safety lighting?
The transformer of the lighting circuit is a step-down transformer (general input 10kv., 220V). The first coil of the autotransformer is shared and connected together
Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
We are now looking forward to your kind cooperation, and will be highly appreciated for that. We sincerely hope to cooperate with you in the lighting field. Please don't hesitate to contact us at your convenience.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range