Dimmable LED Power Supply by Triac dimmer 120VAC 12 Watt 350MA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 300000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features:
12W 350mA Dimmable LED Power Supply For High Power LED Lighting Source
Input range from 120Vac +/- 6%
Work with leading edge and trailing edge dimmers
With power factor correction function:PF>0.9
Compact,lightweight in plastic case
Designed for indoor application
Protections:short-circuit/over load/over heat and auto-reset
2 years warranty
RoHs compliant
Specification:
Model No | LD012D-CA10012-26 | LD012D-CA07018-26 | LD012D-CA03536-26 |
| |
Voltage range(VAC) | 120V +/-6% |
| |||
Frequency range | 60Hz |
| |||
AC Current | 0.2A |
| |||
THD | Less than 20% at full load |
| |||
Max inrush current | <15A |
| |||
leakage current | <1mA/120Vac |
| |||
Available Dimmers | 1. Standard light switches
2. Triac based incandescent dimmers(Standard phase-leading edge) 3. Electronic low voltage dimmers(Reverse phase-trailing edge)
|
| |||
Voltage range(VDC) | 7-12V | 12-18V | 24-36V |
| |
Ripple&Noise(max) | 2Vp-p | 2Vp-p | 2Vp-p |
| |
Rated current range | 1000mA +/-6% | 700mA +/-6% | 350mA +/-6% |
| |
Rated Power | 12W Max | 12W Max | 12W Max |
| |
Efficiency | 81% | 80% | 82% |
| |
Hope up time | Half cycle minimum at 120VAC and 80% of rated |
| |||
Operating Temp. | -20°C to + 50°C full load |
| |||
Operating Humidity | 20%-90% RH non-condensing |
| |||
Storage Temp./Humidity | -20°C to + 80°C 20%-90% RH |
| |||
Ambient Temp. | -25°C at 120Vac |
| |||
MTBF | >100000 hours at full load and 25°C ambient conditions |
| |||
Safety standards | UL, Cul 1310 class2, FCC PART15 CALSS B | ||||
- Q:Is the substation separate from the power and illumination transformer?
- The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
- Q:The transformer zero line has broken, has the result to the household illumination circuit?
- No, the zero line of the transformer doesn't go through the zero line of the transformer. It is a star connection, and the center point is zero line
- Q:3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
- Pure resistive load, the power factor is 1.3 *100W=300W, is required for the capacity of the transformer.
- Q:Who knows how big transformers and lines the 36V transformer uses in lighting?
- The sectional area of the wire can be calculated according to the electric power formula. The current required by the wire is calculated, and then the reference to the national standard "500 volt copper core insulated wire, long term continuous load allowable ampacity meter" is selected.
- Q:Why should lighting transformers be used in factories and mines?
- In some factories and mines (such as power plants), in order to supply power reliability, the power system is grounded in a three-phase, ungrounded, or neutral manner. In this way, the transformer must be connected to a neutral grounding type with a special transformer to supply power to the lighting.
- Q:Why is the two side of the lighting transformer grounded?
- Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
- Q:What transformer can be used in a safety voltage lighting transformer?
- Early European countries used in the power industry, widely used in the electronic industry or industrial and mining enterprises, machine tools and machinery equipment general circuit control power supply, safety lighting and indicator light power supply.
- Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- I don't know how much the output voltage of your transformer is, but the internationally accepted voltage below 36V is the voltage that is not harmful to the human body
- Q:Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- Double winding type safety isolating transformer load end and the power supply terminal is not connected, is safe, and autotransformer primary winding of a share, it is directly connected with the power supply end of the power, not safety.
1. Manufacturer Overview |
|
---|---|
Location | Guangdong,China (Mainland) |
Year Established | 2005 |
Annual Output Value | |
Main Markets | North America 0.36% South America 1.26% Eastern Europe 0.36% Western Europe 1.41% Central America 6.22% Northern Europe 0.36% Southern Europe 1.41% Domestic Market 88.62% |
Company Certifications | TUV; Business License |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | 3,000-5,000 square meters |
No. of Production Lines | 2 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range |
Send your message to us
Dimmable LED Power Supply by Triac dimmer 120VAC 12 Watt 350MA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 300000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords