High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
50000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Place of Origin:

Zhejiang, China (Mainland)

Brand Name:

cnbm

Model Number:

VV YJV VV22 YJV22 VV32 YJV32 VV62 YJV62 VV72 YJV72 YJLW02 YJLW03 KVV

Insulation Material:

PVC or XLPE

Type:

Low,Medium and High Voltage

Application:

s electric power distribution networks or industrial installations

Conductor Material:

Copper or Aluminium

Jacket:

PVC or PE

Filler:

Non-hygroscopic Polypropylene(PP)

Binder Tape:

Non-woven fabric

Metallic Armour 1:

Galvanized Stainless Steel Tape Armour(STA)

Metallic Armour 2:

Galvanized Stainless Steel Wire Armour(SWA)

Metallic Armour 3:

Non-magnetic Steel Tape Armour(only for single core)

Metallic Armour 4:

Aluminium Wire



Packaging & Delivery

Packaging Details:wooden drum; iron-wooden drum or steel drum
Delivery Detail:Depending on the quantity

Specifications

2015 new product electric power cable 
1 Conductor:Copper or Aluminium 
2 Insulation:PVC or XLPE 
3 Voltage:Low/Medium/High Vol

2015 new product electric power  cable  

Technical Parameters of our Power Cable 

1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890

2). Detailed description or construction:

    * Conductor: compacted or uncompacted copper or aluminium

    * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)

    * Filler: Polypropylene filament with lapped binding tape

    * Binder: Binding tape

    * Inner sheath: Polyvinyl chloride (PVC)

    * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)

    *Sheath: Polyvinyl chloride (PVC)

3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:

    U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV

4). Voltage:

     0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV

    In the voltage designation of cables U0/U(Um):

        * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;

        * U is the rated power frequency voltage between conductors for which the cable is designed;

        * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.

5). Application:

     For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.

6). Marking: According to the customers' requirements

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

High Quality Double Insulated and High Tension Lead out Cable for Underground Electric Cable

FAQ

·         Can we make an OEM order?

o    We can offer or supply goods as customers' requirements.

·         How can I get some samples? Free or not?

o    We can send some normal samples, absolutely free.

·         How does your factory do regarding quality control?

o    "Quality is priority." We always attach great importance to quality controlling from the very beginning to the very end. Our factory has gained ISO9001 , SGS authentication, CE for Europe, etc.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the use of wire and cable per square meter of residential building?
Generally wear SC65 tube. If the distance is too long, elbow and more, then the choice will be larger.
Q:"Cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area
What kind of clothes do you want to do? General to high-speed sewing machine, the most important three-line lock machine, hot Taiwan, such as a suit to buy a pressure machine, workstations
Q:Construction of hydropower embedded pvc pipe after the solidification of the pipe after the flat tube
Cable model NHYJV3 * 25 + 2 * 16 its name is: fire-resistant cable. NH ----- on behalf of fire. YJV ----- XLPE insulated PVC sheathed power cable. 3 * 25 ----- 3 cable cross section is 25 square (for 3 phase line with). 2 * 16 ----- 2 cable cross section is 16 square (one for the neutral line, one for the ground line). Fire-resistant cables are generally used for TN-S power supply systems (five-wire).
Q:Pvc threading tube packaging film how to do attractive, on the grade it? Thank you great god
ZR-KVVRP-500 is mainly used for transmission control, measurement signals and other cables. ZR: Control cable KVVRP: PVC insulation 500: Rated voltage 500 V or less 1 × 2: Two core 1.5: Wire diameter
Q:What is the installation specification for the cable tray bracket?
You ask the question is the installation of the trough or concealed it? If it is installed that is the first line and then drill the drill hole with the impact of drilling holes after the new material with a new material. If it is concealed there is no such problem that is buried pipe buried in the wall on the line
Q:Ask you a question: how the computer CD-ROM power supply 5V and 12V two lines? Another audio and video cable which group?
My computer --- right-click properties. Device Manager. Look at the USB device is not there or the number. Have to reinstall the system. Also make sure your motherboard USB interface is not good. I said the interface is plug USE jumper of the root.
Q:TV tiger when the set-top box when tv / ay look for a look on the platform
. the first two said two cables, KW is KVV that PVC insulated jacket control cable. . the control cable for industrial and mining enterprises, energy and transportation sector, for the exchange rated voltage 450/750 volts below the control, protection lines and other occasions, the use of PVC insulated, PVC sheathed control cable. . the performance difference: the power cable in the main line of power systems used to transmit and distribute high-power power, control cable from the power system distribution point of electricity directly to a variety of electrical equipment, power equipment, power lines. The rated voltage of the power cable is generally 0.6 / 1kV and above, the control cable is mainly 450 / 750V. The same specifications of the power cable and control cable in the production, the power cable insulation and sheath thickness than the control cable thick.
Q:Computer host configuration of about 1,000 yuan (preferably 1000 below) - probably as follows;
Cable trench as a power construction project should be cable trench construction construction design, cable trench construction program, according to the previous design requirements and programs in order to develop cable trench construction quality acceptance procedures
Q:What is the difference between the control cable and the compensation cable?
The reason why the wire outside the casing, is to protect the wire insulation from external damage. And the wire laying in the cable tray. The bridge has been gas to the protection of the role, so no longer outside the casing
Q:Copper core power cable laying cable sets what fixed
BTS is 2G base station, a wireless network consists of N BTS and several BSC, each BTS need to access the BSC through the transmission network. 2G base station transmission interface is mostly 2M interface. SDH (Synchronous Digital System), is a technical system developed by ITU, is a transmission technology. SDH line side (that is, out of the cable) is 155M, 622M, 2.5G, 10G optical interface. Branch side (then business network equipment, including base stations) are more than 2M, FE, GE also has 155M optical interface. DDF and ODF are patch panels, DDF digital patch panels, ODF fiber patch panels. SDH line side of the ODF frame, is received on the outgoing cable, DDF frame service network equipment, in the base station is then BTS. Set the patch panel is mainly for easy maintenance, you can label on the patch panel, each interface business type is very clear. The communication system diagram in the base station is this: BTS - DDF - SDH - ODF - another bureau.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range