• China Towel Factory Light Color Bath Cotton Terry Towel Weaving Machine System 1
  • China Towel Factory Light Color Bath Cotton Terry Towel Weaving Machine System 2
China Towel Factory Light Color Bath Cotton Terry Towel Weaving Machine

China Towel Factory Light Color Bath Cotton Terry Towel Weaving Machine

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
1 unit
Supply Capability:
1 unit/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

1. Details

 

Type: Water Jet Loom

Place of Origin:Jiangsu, China (Mainland)

Model Number:JSD508-150cm

Production Capacity:99.99%

Dimension(L*W*H):4500x2500x2600mm

Weight:2500KG

Power(W):1.5KW

Warranty:1 year

Reed Width:150cm,170cm,190cm,230cm...

 

2.Packaging & Delivery

 

Packaging Details:nude packing or as customer's request

Delivery Detail:Within 20days after get the T/T payment

 

3. Specification

 

1,Reed Width:   150,180,200,230,250,280,320

2,Rotation Speed: 170-200RPM

3,Weft Feed :Soft tape ,carbon fiber carries

4,Terry formation: Dobby control, Reed shifting motor

5,High of pile : 13mm

6,Beating : Crank shaft beating 

7,Type of towel :3 wefts or 4 wefts or 5 wefts towel 

8,Ground warp let -off: Sensors control, Gear reducer

9,Drive frange Dia:550,600

10,Power: 1.5kw

 

4.FAQ

 

Q: How long time guaranteed we furnish?
A: One year after installing the machine

Q: What is the delivery time?
A: One month since the payment will be received

Q:Why we choose you?
A:We are gated company and member of top 500 company in the world

 

5.Images

 

 

Q:What is the working principle of centrifugal fans?
The pressure generated in the centrifugal fan is greatly influenced by changes in the inlet temperature or density. For a given intake air volume, the maximum intake air temperature (lowest air density) produces the lowest pressure. For a given pressure and flow characteristic curve, there is a power and flow characteristic curve. When the blower runs at constant speed , The required power increases with a decrease in the intake air temperature for a given flow rate.
Q:What is the difference between a blower and a blower?
The same point: called the fan, are used for air. Differences: one is 'send' into, one is 'drum' into. Wind pressure is different, different shape, use is not the same.
Q:Why should the safety valve be installed at the Roots blower exit?
Even if the fan outlet is completely blocked (in fact, start the centrifugal fan should be closed the outlet) will not cause damage to the fan.
Q:What kind of duct valves are required in the exhaust duct and near the fan?
Mechanical exhaust system due to the fan as a power, can effectively control and distribution of air volume (which is the biggest difference with the natural ventilation), so the system piping (ie duct) need to set the air volume control valve.
Q:What is the difference between high pressure air blower and medium pressure air blower?
The impeller of the pressure fan (also known as centrifugal fan) is covered with a mechanical housing, and the center of the impeller is the air inlet.
Q:What are the characteristics of high-pressure axial fans?
2. High reliability When the use of changes, the machine can still operate safely. In addition to the impeller, the high pressure blower has no other action, so the reliability is almost free of maintenance. It has the following advantages: high compression ratio; low bearing running temperature; long life of lubricating grease; maintenance-free.
Q:What is the difference between a jet fan and an axial fan?
When the fan is running, through the blade hydraulic adjustment device, can adjust the blade installation angle, and maintain a certain angle, so that it works in the variable conditions still have a high efficiency.
Q:What are the regulations for the air volume of the exhaust fan?
Bear two or more smoke partition smoke, should be the largest smoke partition area per square meter of not less than 120m3 / h basis.
Q:What is the difference between a volute fan and a centrifugal fan?
Centrifugal fans include a volute bulk fan (Housed centrifugal fan) and a voluteless centrifugal fan (Unhoused centrifugal fan).
Q:How to deal with axial fan noise?
For the noise generated by the impeller, usually through the blade perforation approach to reduce noise, with the perforation method, you can make part of the air flow through the blade high pressure surface to the leaves low pressure surface, can promote the leaf separation point to move below the flow

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords