Grounding Reels Static Reels Retractable Wire Reel

Ref Price:
$150.00 - 250.00 / kg
Loading Port:
Qingdao
Payment Terms:
L/C,T/T
Min Order Qty:
50 Sets kg
Supply Capability:
200 Set/Sets per Day kg/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 Grounding Reels Description

 

Grounding Reels are used extensively with chemicals, tank cars and storage tanks; It can be mounted directly to the grounded surface; Its stainless steel cover is high corrosion resistance.

 

Grounding Reels are made in stainless steel, so that it can be used in the area where high corrosion resistance is required, and it can be mounted directly to the grounded surface.

It has a self-retracting cable drum and instant lock mechanism to prevent cable becoming tangled. The latching mechanism holds the cable at any desired length. By pulling slightly on the cable, it will release the mechanism causing retraction.

 

The standard models include the SC-01 static grounding clamp and 7m cable.

Available in 10m and 15m options, with PU cable.

 

Weight: 3 kgs

Dimension: 210 m m×64.5 m m×170 mm 

 

Packaging & Shipping

 

Each 5 pcs is packaged in one carton box

(diamensions:60cmX30cmX38cm)

Shipping is depended on customer, either by sea or courier such as FedEx, DHL, TNT or UPS

Lead Time: 7 days after the payment

 

Why Choose Us

1) Excellence in the industry with over 18 years’ experience

2) Good reputation

3) High quality guaranteed

4) Competitive factory-direct sale price

4) Prompt Delivery 

5) Good after-sales service 

 

Our Service

1) Accept urgent order

2) Keep smooth delivery on time

3) Free sample, the sample fees will be returned after placing an order

 

Company Information

We are the leading manufacturer of Overfill Prevention & Grounding Systems in China and we are serving 8910 customers in and out of China.

 

Why we choose Okorder.com?

Okorder.com is a professional and reliable online E-market place

Providing a variety of products with reasonable prices

High quality goods provided by factory suppliers

Shipping to over 200 countries.

One-stop sourcing

Dubai Logistic Complex

 

Okorder Quality Control?

We hold a very strict quality control system to check every connector of our products for your safety.

 

Okorder services for you

1.7*24 hours Hotline & Email Service

2. Your inquiry related to our products or prices will be replied in 24hrs.

3. Well-trained and experienced staffs to answer all your enquires in fluent English

4. OEM&ODM, any your customized demand we can help you to design and put into product.

5. Distributor ship are offered for your unique design and some our current models

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What is the difference between a pre-branch cable and a punched clip?
1 Latex reclaimed rubber, the use of Malaysia imported rubber tree waste plastic cups, plastic yarn and latex products factory condensed waste as raw materials, with Ji Dai flooding fried ghosts kill Handan fine fineness, easy color, , Feel good elasticity, high elongation at break, no need to plastic and so on
Q:What is the difference between public relations firms and media companies?
Is the separator divides the bridge into 2 and a half, usually with two different roles of the cable at the same time laying in a cable bridge, such as the power cable with the signal cable with the bridge laying, in order to avoid electromagnetic interference, with separator separation.
Q:Is the power cable considered a fixed asset?
According to the total number of meters, such as where to where a total of how many kilometers (meters). Power system fixed assets asset management software - TU Teng fixed asset management software.
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:Whether the interior decoration is the first brush latex paint or the first installation of the wire (the line, with the trunking)?
3 + 2 and 4 + 1 are the number of cores of a cable, a cable inside is not a line, is insulated with each other 2 or . 3 +. 4 +1 line, 5 lines , Respectively, called 2 core or 3 core, 3 +2 core, 4 +1 core, 5 and other core. 3 + 2 cable 3 is the three phase lines, the diameter of the line as large, 2 is the zero line and the PE line, the diameter of the line as large; 4 + 1 cable 4 is the same as the three lines and the same diameter, 1 is the PE ground wire is a separate diameter; five core is the phase line, zero line and PE line are the same diameter, 2 core and 3 core is also the diameter of the line. In the end with a few cable, the design specifications are provided! A few words are not clear!
Q:How to convert the computer's audio and video to cable TV signals. Through the cable television transmission to the 40 TV (hurry)
The first is to buy a computer connected to the TV dedicated audio and video lines, length specifications are: 1.8 meters, 5 meters, 10 meters, 15 meters and 20 meters, etc., everywhere sold here do not do a detailed introduction to the first step: , S-terminal video cable connection S plug the end of the line into the video on the S terminal port, while the other end of the S-terminal line into the TV behind the S terminal port, the connection is completed (Figure 1); if you You can use the "S-AV adapter" supplied by OUR to connect the S-terminal connector to the S-terminal cable, and then insert the AV head of the other head into the AV video input after the TV Mouth, the connection is completed (Figure 2). . the audio cable connection will be the audio line of the two Lotus head were inserted into the TV after the left and right channel audio input port, while the audio cable 3.5mm audio head into the audio card audio output port, the connection is completed. If you need to use the "one sub-two audio frequency line", then its 3.5mm audio head into the audio card audio output port, speakers (headphones) and audio lines were inserted into the "one two audio frequency line" 3.5 Encyclopedia of Germany, Germany and Germany Bao Bao mother on the mouth, the connection is completed
Q:Power cable 5-color line, respectively, what color, what role?
YJ: cross-linked polyethylene insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated voltage: 8.7 / 15 kV 3 * 300: three conductor cross-section of 300 square copper conductor Another: such as YJLV Is the aluminum core. Here is not marked what the material is conductor, you can default to copper conductor.
Q:What are the lines that need to be set up for notebooks?
Friends, shielded cable is a layer of mesh copper or metal wire woven from one or more wires surrounded by a cable, this layer of mesh to prevent lightning, the outside signal can not interfere with it, and control cable is used To control the device to start the protection circuit, etc., in general occasions do not need to shield, with the general insulated wire on it, as long as the load on the line.
Q:The power cable troughs are divided once and twice
Can be used for overhead, buried and pipeline laying of the cable line
Q:PVC pipe line 6 points and 4 points which big ah?
The bearing capacity of the square millimeter in the wire decreases with the increase of the wire diameter, for example, 1 mm square meter

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range