Galvanized Steel Wire For Pvc Coated Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Hot Dip Galvanized Steel Wire
(1) Quality : Meet GB/T 343 standard and other requirements of relevant standards .
(2) Zinc Coating: Meet GB/T 15393 standard and other requirements of relevant standards .
(3) Raw Material : Wire rod ——1006 , 1008 , 1018 , Q195 , etc, and zinc with 99.995% purity.
(4) Tensile Strength Range
Size (mm) | Tensile Strength (mpa) |
0.15-1.60 | 290-550 |
0.65-1.60 | 400-550 |
1.61-6.00 | 400-1200 |
(5) Application : Used in wire mesh , artware , metal hose , binding for agriculture and construction , etc.
(6) Packing
Size (mm) | Coil Size | Spool Packing | Big Coil Packing | |
ID (mm) | OD (mm) | |||
0.15-0.26 | 6 inch | 1-14kg/spool |
|
|
0.27-0.60 | 8 inch | 1-100kg/spool |
|
|
0.61-1.60 | 12/14/16 inch | 1-100kg/spool | 250-400 | 400-770 |
1.61-6.00 |
| 14-500kg/spool | 450 | 800 |
508 | 840 |
(7) Zinc Coating
Meet GB/T 15393 standard.
Size (mm) | Weight of Zinc-Coating ( g/m2 ) | |||||||
A | AB | B | C | D | E | F | ||
A1 | B2 |
|
|
|
|
|
| |
≤0.25 |
|
| 30 | 20 | 18 |
|
|
|
>0.25-0.40 |
|
|
| 30 | 25 | 20 |
|
|
>0.40-0.50 |
|
|
|
| 30 | 20 |
|
|
>0.50-0.60 |
|
|
|
| 35 | 20 |
|
|
>0.60-0.80 | 120 | 110 |
|
| 40 | 20 |
|
|
>0.80-1.00 | 150 | 130 |
|
| 45 | 25 |
|
|
>1.00-1.20 | 180 | 150 |
|
| 50 | 25 |
|
|
>1.20-1.40 | 200 | 160 |
|
| 50 | 25 |
|
|
>1.40-1.60 | 220 | 180 |
|
| 50 | 35 | 30 |
|
>1.60-1.80 | 220 | 180 |
|
| 70 | 40 | 30 |
|
>1.80-2.20 | 230 | 200 |
|
| 80 | 50 | 40 |
|
>2.20-2.50 | 240 | 210 |
|
| 80 | 55 | 40 |
|
>2.50-3.00 | 250 | 230 |
|
| 90 | 70 | 45 |
|
>3.00-4.00 | 270 | 250 |
|
| 100 | 85 | 60 | 30 |
>4.00-5.20 | 290 | 270 |
|
| 110 | 95 | 70 | 40 |
>5.20-6.00 | 290 | 270 | 245 |
| 110 | 100 | 80 | 50 |
- Q:A wire has a resistance of 21.0 ohms. It is melted down, and from the same volume of metal a new wire is made that is three times longer than the original wire. What is the resistance of the new wire?
- The resistance of the new wire is (in terms of its length, area resistivity); R2 = pL2/A2 And the resistance of the original wire is; R1 = pL1/A1 The ratio is;(resistivity will cancel because its the same for both situations) R2/R1 = L2A1/L1A2 given L2 = 3L1 R2/R1 = 3A1/A2 To find the new cross-sectional area ,require the volumes to be equal; L2A2 = L1A1 3L1A2 = L1A1 A2 = (1/3)A1 Sub this into the R2/R1 equation to get; R2/R1 = 9 R2 = 9R1 = (9)(21) = 189 ohms
- Q:installing ceiling fan, when remove light fixture, it has 4 wires system, wires used: white red and green with one light switch, what is black for, it has a wire nut, but has nothing connect to it
- Either way green is ground, white is common, red is live and black is live. It is technically irrelevant which is which but black and red are one each for the fan and optional light. If black has a wire nut on it leave it that way it is for the optional light.
- Q:(PRIOR TO READING, I SUGGEST YOU LOOK AT THE IMAGES AS IT WILL MAKE THINGS A WHOLE LOT EASIER TO UNDERSTAND)I purchased 2 neons from Repco. That run off your cigerette lighter with an adaptor. They worked fine, until my friend got in my car, and accidentally dropped something on the adaptor which caused it to malfunction, and bam, my in-car neons (placed up under the dash, near where your feet rest) went out.
- wire is wire. If it really is silver then theoretically it should conduct electrcitiy better than copper. But that doesn't really matter much. wire is wire. all it needs to be able to do is carry the electrical current. If wiring truly is your problem, then that will work fine.
- Q:I had my uncle-in-law hook up my American Bass Pro 800 Watt Amp but he used cheap wiring. The wire is fairly small and he told me it doesnt matter how big the wire is. But what i wanna know is, Is the wire giving the amp enough power or does American Bass Pro Amps suck?? Help please
- your uncle obviously doesn't know what he's talking about. You can tell him I said that. If you want to get a lot of water to your garden, you use a bigger hose. If you want to get a lot of power to your amp, you use a bigger wire.
- Q:A long horizontal wire carries a current of = 52 . A second wire, made of 1.00--diameter copper wire and parallel to the first, is kept in suspension magnetically 5.0 below.What is the magnitude of the current in the lower wire?
- The lower wire is kept in suspension magnetically means that the downward force of gravity is equal to the upward magnetic force. Its NOT an easy problem so we need to solve it in small steps. Let's find the two forces acting on the lower wire: (*) Downward force of gravity = mg = (volume) x (density) x (gravitational acceleration) = (pi r^2 L) x(8920)x(9.8) = 0.06896L We assume the radius of the wire is 0.5 mm or 0.0005m, copper density is 8960 N/m^3, gravitational acceleration = 9.8 m/s^2 (**) Upward magnetic force = mu(zero) x i(one) x i(two) x L / (2 pi d) = 2.08x10^(-4) L i(two) mu(zero) is a constant = 4 pi 10^(-7), i(one) is the current in the first wire = 52A, i(two) is the unknown current in the second wire, d is the distance between the wires = 5 mm or 0.005m The forces are equal, therefore 0.06896L = 2.08x10^(-4) L i(two) We divide both sides by L (the unknown length of the lower wire) and now we can solve for the current i(two) ANSWER: i(two) = 331.5 A
- Q:what size of wire should I use for my 1.5hp aircon, 220volt
- You should use AWG 14 Copper wire.
- Q:my speaker makes a fuzzy or static noise while the scene has high or low sound. I cut my wire in half because I bought a subwoofer and we didn't get the wires with it. So I cut it. After all I didn't need the wire for the subwoofer. Could my speakers make such noises because of cutting a wire?
- I have no idea what you did. Which speaker(s) makes a static noise? You cut your wire in half. Which wire? Is your subwoofer wired to the speaker outputs or the SUB OUT on the receiver? Did you splice this wire or simply trim it, strip the ends and plug it into the receiver speaker outputs and the terminals on a speaker? What are you powering these speakers and subwoofer with? A receiver or an all in one HTIB unit? The best way to get good answers with any question is to provide as many details as possible - model numbers and the conditions under which the problem occurs. Details please.
- Q:Kind of a confusing question I guess. I want to cut a wire that contains 3 other wires and splice into them then reconnect them. is all I need relatively the same gauge wire or is it potentially different type like some sort of special speaker wire..? Should be one positive one negative and the other some sort of signal for sound. (Microphone to a speaker). All I need is standard copper wire?
- Hello Rocky: You need to be more specific. What are you attempting to do? I know you want to splice a three-ply wire, but what is your end purpose?
- Q:Two current-carrying wires are lying right on top of each (at a right angle) other, with currents flowing in the wires in the directions pointing up for the vertical wire and to the right for the horizontal wire. The horizontal wire is fixed and does not move. What happens to the vertical wire?Choices:It moves out of the pageIt rotates clockwiseIt rotates counter-clockwiseIt moves to the leftIt moves to the rightIt moves into the page
- i'm uncertain we've a sparkling theoretical answer to this although that is a demonstrable fact that shifting quotes have an effect on different shifting or movable quotes.even while there's no internet value obtrusive it is summarized as magnetism
- Q:Just need a wiring diagram link that shows all wires and possibly steps on installing an aftermarket stereo.
- See okorder ...
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Galvanized Steel Wire For Pvc Coated Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords