1.Manual Wafer Butterfly Valve Description

A butterfly valve is a valve which can be used for isolating or regulating flow. The closing mechanism takes the form of a disk. Operation is similar to that of a ball valve, which allows for quick shut off. Butterfly valves are generally favored because they are lower in cost to other valve designs as well as being lighter in weight, meaning less support is required. The disc is positioned in the center of the pipe, passing through the disc is a rod connected to an actuator on the outside of the valve. Rotating the actuator turns the disc either parallel or perpendicular to the flow. Unlike a ball valve, the disc is always present within the flow, therefore a pressure drop is always induced in the flow, regardless of valve position.

2.Main Features of the Manual Wafer Butterfly Valve 

1)Small in size and light in weight and maintaince.It can be mounted whereever needed.

2)Simple, compact structure, quick 90 degree on-off operation.

3)Disc has two-way bearing, perfect seal, without leakage under the pressure test.

4)Flow curve tending to straight-line. Excellent regulation performance.

5)Various kinds of materials, applicable to different medium.

6)Strong wash and brush resistance and can fit to bad working condition.

7)Center plate structure, small torque of open and close.

8)Long service life. Standing the test of ten thousands opening and closing operation.

9)Can be used in cutting off and regulation medium

3. Manual Wafer Butterfly Valve Images

 Butterfly Valve Manual Wafer High Quality

 

Butterfly Valve Manual Wafer High Quality

Butterfly Valve Manual Wafer High Quality

4.Manual Wafer Butterfly Valve  Specification:

Size

DN40-DN1200

End flange

ANSI B 16.1, EN 1092, AS 2129

Face to face

ANSI B 16.10; EN 558-1 Series 20

Top flange

ISO 5211

Normal Pressure

DN40-DN600 PN1.0/1.6MPa (150/200PSI) DN700-DN1200 PN1.0MPa (150PSI)

 

Body

CI/DI/WCB/ALB/CF8/CF8M

 

Disc

DI/ALB/Rubber lined Disc/ 1.2501/CF8M/1.4529/CF8/Hastelloy Alloy/Monel

Stem:

416/304/316/431/17-4PH

Seat

NR/Hypalon/EPDM/Neoprene/NBR/Wear-Resistant  EPDM/Viton/Silicon/Heat-Resistant EPDM/White NBR/White EPDM/EPDM (NSF)/PTFE

Suitable Temperature

-40c~80c

 

Apply

Fresh water, sewage, sea water, air, vapor, food, medicine, oils, alkalis, salt etc.

5.FAQ

1. What is manual wafer butterfly valve?

Wafer style is the more common of the two and is less expensive than the lug style. The wafer style butterfly valve is just about the standard. It ís so common that no one even bothers to use the word "wafer" when ordering abutterfly valve. It is taken for granted that if a butterfly valve is ordered, a wafer style will be received.

2. How about the Installation of the Wafer Style Butterfly Valve?

Butterfly valves are installed by inserting the valve between two flanges using bolts or studs and nuts to hold it all together. This type of installation, of course, makes it impossible to disconnect just one side of the piping system from the valve. That benefit is received using the lug style valve.

3. What is the working principle of manual wafer butterfly valve?

A butterfly valve is from a family of valves called quarter-turn valves. In operation, the valve is fully open or closed when the disc is rotated a quarter turn. The "butterfly" is a metal disc mounted on a rod. When the valve is closed, the disc is turned so that it completely blocks off the passageway. When the valve is fully open, the disc is rotated a quarter turn so that it allows an almost unrestricted passage of the fluid. The valve may also be opened incrementally to throttle flow.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Ok, My zone-valve is dead. How do i find/fix it?
if your sure its not the thermostat than the zone valve should be near the boiler in the copper line. Most valves have a flat lever that slides when it is powered up to open. You can open manually by sliding the lever
Q:Butterfly valve D71X-10 and butterfly D371X-10 what is the difference?
Different structure. The handwheel (or handle) of the D71X-10 is mounted directly on the valve stem, and the D371X-10 is operated by means of a bevel gear in combination with the worm, and the handwheel is mounted on the worm.
Q:QUestion about Valves during cardiac cycle?
A heartbeat is a two-part pumping action that takes about a second. As blood collects in the upper chambers (the right and left atria), the heart's natural pacemaker (the SA node) sends out an electrical signal that causes the atria to contract. This contraction pushes blood through the tricuspid and mitral valves into the resting lower chambers (the right and left ventricles). This part of the two-part pumping phase (the longer of the two) is called diastole. The second part of the pumping phase begins when the ventricles are full of blood. The electrical signals from the SA node travel along a pathway of cells to the ventricles, causing them to contract. This is called systole. As the tricuspid and mitral valves shut tight to prevent a back flow of blood, the pulmonary and aortic valves are pushed open. While blood is pushed from the right ventricle into the lungs to pick up oxygen, oxygen-rich blood flows from the left ventricle to the heart and other parts of the body. After blood moves into the pulmonary artery and the aorta, the ventricles relax, and the pulmonary and aortic valves close. The lower pressure in the ventricles causes the tricuspid and mitral valves to open, and the cycle begins again. This series of contractions is repeated over and over again, increasing during times of exertion and decreasing while you are at rest. The heart normally beats about 60 to 80 times a minute when you are at rest, but this can vary. As you get older, your resting heart rate rises. Also, it is usually lower in people who are physically fit.
Q:What type of butterfly valves do you have in DN125?
125D42X: manual double eccentric flange butterfly valve 125D3 (6, 9) 42X: worm (gas, electricity) double eccentric flange butterfly valve125D41X: manual single eccentric flange butterfly valve 125D3 (6, 9) 41X: worm (gas, electricity) moving single eccentric flange butterfly valve125D43H: manual three eccentric flange butterfly valve (hard seal)125D3 (6, 9) 43H: worm (gas, electricity) move three eccentric flange butterfly valve (hard seal)125D71X manual alignment type butterfly valve125D3 (6, 9) 71X worm (gas, electricity) midline type clip butterfly valve125D3 (6, 9) 73H, worm (gas, electricity) three eccentric pair clip butterfly valve (hard seal)125BD71 (F4) X corrosion resisting fluorine (wrapped) pair clip butterfly valve
Q:The difference between butterfly valve d71x_10s and d341s-10
Before distinguishing between the two, you must first read the identification of the valve type:D stands for butterfly valves,3 means that the worm gear is connected and the drive does not indicate the handle7 and 4 indicate pipe to clamp connection, pipe flange connection, respectively1 means single eccentric, that is, the stem is not in the center of the butterfly plateThe former S indicates the material name of the valve body - plastic, X means sealing and the lining material is rubberThe latter S indicates the sealing lining material code ---- plastic, and the valve body is cast iron.10 means stress.
Q:Butterfly valve in use when should pay attention to what problems?
In the process of using the butterfly valve, you should timely notice valve state, without excessive loosening, no abnormal leakage, or abnormal high temperature and so on, if there is abnormal, should immediately close the valve, to identify the reasons for the problem, treatment after use, it is also very important.
Q:D what's the meaning of "one 71x one 1 butterfly"?
According to the provisions of the JB/T 308-2004 valve type programming method:D== butterfly valve7== clip typeLinetype in 1==X== sealing surface material: Rubber-1== pressure rating: 1.0MPa
Q:Does the wet alarm valve group need to install the signal butterfly valve?
Wet alarm valve at the front of the signal butterfly valve with the main floor of the main role of the butterfly valve, first, maintenance, and two is the prompt sprinkler system, there is a signal butterfly valve closed, should be repaired as soon as possible.
Q:Butterfly valve model D344H and D343 difference
In fact, almost all refers to the sealed variable eccentric butterfly valve.1, D344H-10C DN4002, D343H-10C DN400Let's talk about the similarities between the 2 Butterfly models: D stands for butterfly valves, 3 represents turbine drivers, and the middle 4 represents flanged connections,10 represents the pressure of 10 kg, C represents the butterfly valve, the material is cast steel, and DN400 stands for the caliber of the valve;To say that where there are differences between the 2 models, there is a place where there are differences, second means 4 of the first models is the new type sealing valve structure is variable eccentric, second of the second models of the 3 represents the structure of the valve is three eccentric, and three eccentric seal variable eccentric type is in fact a meaning.Sealed three eccentric butterfly valve, sealed variable eccentric butterfly valve, corresponding to the central butterfly valve and sealed single eccentric butterfly valve.
Q:where is the pvc valve located on duramax diesel?
The last two answers were wrong. Duramax motors have a Pcv valve. It stands for positive crankcase ventilation and every engine has one that I am aware of and it's to relieve the air pressure built up in the crankcase from the pistons moving up and down. The Pcv allows atmospheric air pressure inside then crankcase. If there is a lot of air pressure coming out of the Pcv you could have bad valve seals or worn piston rings allowing massive amounts of air being forced into the crank case. The Pcv valve on 2003 and older have the Pcv built into the valve cover. It is a box shape cap that has a spring and diaphragm under it. Old question just thought I would clear that up for the 2 people not so mechanically inclined that answered last.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range