Rack Tower UPS HP9115CRT 1-10KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Units pc
- Supply Capability:
- 4500 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Key Features:
Rack & Tower Design UPS
0.8 Output Power factor
LCD Display
Intelligent slot available
pure high frequency online UPS,with voltage adjustment circuit, provide stable power protection in bad operation environment
comprehensive electrical isolation protection and bypass protection, self test function
Input neutral and live wire detection function and data protection function
Main power failure,going to DC staring ,Convenient and reliable; Main power recover,UPS start automatically
Model | HP9115CRT 1-10KVA | HP9315CTR 10KVA | ||||||||||||||||||||
1KR/1KR-XL | 2KR/2KR-XL | 3KR/3KR-XL | 6KR/6KR-XL | 10KR/10KR-XL | 10KR/10KR-XL | |||||||||||||||||
1KVA/800W | 2KVA/1600W | 3KVA/2400W | 6KVA/4800W | 10KVA/8000W | 10KVA/8000W | |||||||||||||||||
220/230/240VAC | 380VAC | |||||||||||||||||||||
50/60 Hz | ||||||||||||||||||||||
115~295VAC(±3VAC) | 176~297VAC(±3VAC) | 304~478VAC(±3VAC) | ||||||||||||||||||||
50HZ:(46~54HZ);60HZ:(56HZ~64HZ) | ||||||||||||||||||||||
>0.98 | ||||||||||||||||||||||
220/230/240X (1±2%)VAC | ||||||||||||||||||||||
50/60HZ±0.05Hz | ||||||||||||||||||||||
0.8(option) | ||||||||||||||||||||||
Linear Load<3% Non-Linear Load<6% | ||||||||||||||||||||||
overload(110%~150%)after 30 seconds automatically transfer to bypass, it recover after normal load | ||||||||||||||||||||||
3:1 | ||||||||||||||||||||||
0ms(AC→DC) | ||||||||||||||||||||||
36VDC | 72VDC 96VDC | 192VDC &240VDC optional | ||||||||||||||||||||
5 hours to 90% | ||||||||||||||||||||||
1A | 4A/8A optional | 1A | 4A/8A optional | 1A | 4A/8A optional | 2.0A/4.2A(option) | ||||||||||||||||
Display input and output voltage, frequency, battery voltage, battery capacity, and the percentage of load | ||||||||||||||||||||||
RS232, SNMP card(option, USB port(option) | ||||||||||||||||||||||
0~40°C | ||||||||||||||||||||||
0~95% non-condensing | ||||||||||||||||||||||
-25°C~55°C | ||||||||||||||||||||||
<1500 meter | ||||||||||||||||||||||
<45dB | <50dB | |||||||||||||||||||||
N.W | 16.5 | 9 | 26 | 11.5 | 26 | 12.5 | 18.5 | 18.5 | 25 | 32 | 25 | 32 | ||||||||||
G.W. | 18.5 | 11.5 | 28 | 14.5 | 28 | 15 | 21.5 | 21.5 | 28.2 | 35 | 28.2 | 35 | ||||||||||
447x450 x130 | 447x600x130 | 447x450x130 | 447x600x130 | 447x450x130 | 447 x600x130 | 447x600x177 | ||||||||||||||||
- Q:Which is more energy saving by using 24V500W transformer lighting and 220V500W lighting?
- See whether the lamp power saving, can not see whether it has a transformer, but to see the light efficiency of the lamp, that is, the ratio of light flux to power!Popular speaking, that is, spend the same electricity to see who sends more light!So, when comparing, ask what the light is, then judge again!The luminous efficiency unit is LM/W
- Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- So, safety regulations: lighting transformer must double winding type safety isolating transformer, prohibited the use of autotransformer.
- Q:Why is the two side of the lighting transformer grounded?
- In the three-phase transformer, the neutral point of the three-phase transformer and the metal case are always reliably connected, and the utility model has the advantages of reliable grounding, both working grounding, protection and earthing, and protection of personal safety and equipment safety.
- Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Generally, the power of the transformer is the apparent power, and the light bulb is the active power, and the power matching is taken into account.
- Q:What type of low voltage transformer should be adopted for safety lighting power supply?
- Isolated transformer, once 380V or 220V, two voltage, 36V, 24V, 12V, several categories, do not allow the use of autotransformer.
- Q:How many A leakage protection switches are used in 5000VA lighting transformers?
- Secondary current =5000VA/220=22A, you can select the 32A leakage protection switch.
- Q:How many power illuminator can 5Kva 36V transformer drive?
- The load capacity of the transformer is 70% of its nominal power, so it is concluded that the transformer you provide can drive the 3.5KVA 36V lighting appliance (which is used in normal condition and environment)
- Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q:How many can you bring with 220V? How many can you bring with 380V? There are 3 terminals on the transformer. There are 220V, 380V, 0, three terminals. 220V is the 220V terminal and the 0 connection. How can the 380V be connected? Is it 380V and 0 or 380V and 220V?
- Because some transformers are connected to 380V and 0, they can be 1000VA capacity, but because of the same line diameter, the 220V terminals and 0 can not provide the capacity of 1000VA.
- Q:How is the lighting power of the 380V transformer calculated?
- The transformer (Transformer) principle should change the AC voltage of the primary coil, the main component of the device level by using electromagnetic coil core (core) main functions: voltage transformation, current transformer, impedance converter, isolation, voltage regulator
1. Manufacturer Overview |
|
---|---|
Location | Guangdong,China (Mainland) |
Year Established | 2006 |
Annual Output Value | US$10 Million - US$50 Million |
Main Markets | 9.09% North America 9.09% South America 9.09% Eastern Europe 9.09% Southeast Asia 9.09% Africa 9.09% Mid East 9.09% Eastern Asia 9.09% Western Europe 9.09% Southern Europe 9.09% South Asia |
Company Certifications | UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | Shenzhen China |
Export Percentage | 61% - 70% |
No.of Employees in Trade Department | 11-20 People |
Language Spoken: | English, Chinese |
b)Factory Information | |
Factory Size: | 10,000-30,000 square meters |
No. of Production Lines | 10 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
Rack Tower UPS HP9115CRT 1-10KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Units pc
- Supply Capability:
- 4500 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords