Product Description
Product Spec | |||
Model | CFE-640S | CFE-1280S | CFE-1280SP |
Nominal Voltage | 12.8V | 12.8V | 25.6V |
Nominal Capacity @1C | 50Ah | 100Ah | 50Ah |
Charge Voltage | 14.8V | 14.8V | 29.6V |
Charge Current Max Continuous | 25A | 50A | 25A |
Discharge Current Max Continuous | 50A | 100A | 50A |
Discharge Voltage Minimum | 10.8V | 10.8V | 21.6V |
Pulse Current 5 Sec | 75A | 150A | 65A |
Weight | 6.7kg±0.5kh | 12.3kg±0.5kh | 12.3kg±0.5kh |
Dimensions L*W*H(mm) | 180*140*210 | 320*140*210 | 320*140*210 |
Calendar Life & Performance Guarantee | a. 3500 cycles or 5 years , whichever comes first a. 3500 cycles or 5 years , whichever comes first |
Product Spec | |||
Model | CFE-2560S | CFE-2560SP | CFE-5120S |
Nominal Voltage | 12.8V | 25.6V | 25.6V |
Nominal Capacity @1C | 200Ah | 100Ah | 200Ah |
Charge Voltage | 14.8V | 29.6V | 29.6V |
Charge Current Max Continuous | 50A | 50A | 50A |
Discharge Current Max Continuous | 100A | 100A | 100A |
Discharge Voltage Minimum | 10.8V | 21.6V | 21.6V |
Pulse Current 5 Sec | 150A | 150A | 150A |
Weight | 22.5kg±0.5kg | 22.5kg±0.5kg | 46kg±0.5kg |
Dimensions L*W*H(mm) | 320*250*210 | 320*250*210 | 320*470*210 |
Calendar Life & Performance Guarantee | a. 3500 cycles or 5 years , whichever comes first b. 1500 cycles or 2 years , whichever comes first |
Test conditions: 0.2C Charging/Discharging, @25°C, 80% DOD
FAQ
CFE Lithium-ion Battery
Q: What kind of battery you can provide?
A: a.12.8V-25.6V 30Ah/40Ah/50Ah/100Ah//200Ah LFP battery for replacement of Lead-acid/Gel battery.
b. 51.2V 50Ah/100Ah LFP battery module for residential energy storage with cube (10,15,20 kwh).
c. Solar hybrid inverters with power 4,5,6,8,10,12kw, solar off grid inverter 3,5 kw.
d. Inverter & Battery ALL IN ONE, with capacity 5,10,15,20 kwh.
e. E-mobility battery for E-scooter, E-bus, E golf cart etc.(Rank Top 3 in China).
f. 48V 50A/100AH/150AH/200AH LFP Battery for Telecom-towers.
Q: What is the capacity of production?
A: CFE has 13 production lines with a total capacity of 12Gwh for both storage and E-mobility.
Q:How long is the warranty period?
A: Our limited warranty is valid for a period 5 years (12.8V products) /10 years (51.2V products) after delivery. It is restricted by specifications and warranty terms.
Q: How long is the estimated delivery time?
A: The delivery time is within 25 days after receiving the payment.
Q: Are you able to handle shipment transportation?
A: We can arrange the shipment to most places as required.
Q: What kind of certification do you have?
A: We have SGS, TÜV, IEC 62040-1, IEC 62109-1, IEC 62109-2, IEC 62619, UN38.3, IEC 62133, CEC, UL, MSDS, ISO 9001 certifications, but each product may be different.
Q: What kind of product quality your factory offer?
A: We provide the most competitive products at the highest quality. (100% cell sorting test under inner resistance ≦2mΩ, voltage differ ≦ 2mV,100% EOL test, 100 % aging, 100% final product testing) .
Q: Can we print our logo on products?
A: We can provide one to one customized OEM with a MOQ demand(Only available with 12.8V products).
Q: What is the validity of the quotation?
A: Due to the raw material price fluctuation, the quotation validity is 10 days.
- Q:What is the difference between a maintenance-free battery and a conventional battery?
- Lead-acid battery is composed of positive and negative plates, partitions, shell, electrolyte and wiring pile head and other components, the discharge of the chemical reaction is to rely on positive electrode active substances (lead dioxide and lead) and negative plate active substances (sponge Pure lead) in the electrolyte (dilute sulfuric acid solution) under the action, which plate grid, the traditional battery lead and antimony alloy manufacturing, maintenance-free battery is made of lead calcium alloy, the former with antimony, the latter with calcium, This is the fundamental difference between the two points.
- Q:The role of the battery?
- It filled with lead plate filled with sponge lead as a negative electrode, filled with lead dioxide lead dioxide as a positive electrode, and with 22 to 28% dilute sulfuric acid as electrolyte. In the charge, the electrical energy into chemical energy, the discharge of chemical energy and into electrical energy.
- Q:80ah how much battery storage capacity?
- 0AH storage is 80AH ah If the actual storage capacity will have to see the brand. I have seen 100AH only 24 pound. This is not even 60AH.
- Q:What kind of battery is divided into?
- Ordinary battery: ordinary battery plate is composed of lead and lead oxide, the electrolyte is sulfuric acid aqueous solution. Its main advantage is the voltage stability, the price is cheap.
- Q:How to determine the battery is good or bad?
- Observe the battery electrolyte is turbid, turbidity that the battery positive plate softening. Observe the bottom of the battery whether there is sediment, if the plate off the battery capacity has been inadequate. Hand hit the battery two electrode piles If you hear an empty voice that pole pile and plate break. With a thick wire short-circuit positive and negative pile observation of the battery filling holes, such as the discovery of a bubble appears that the interval has been damaged.
- Q:What is the meaning of the battery above 12v65Ah?
- Voltage 12V, current 65AH, that is the capacity of 65A. (A is the unit of current. H is the time unit)
- Q:What battery does the van use?
- General use of lead-acid batteries. Electrode is mainly made of lead and its oxide, the electrolyte is a sulfuric acid solution of a battery. English: Lead-acid battery Discharge state, the main component of the cathode is lead dioxide, the main component of the negative lead; charge state, the main components of the positive and negative are lead sulfate. Divided into exhausted batteries and maintenance-free lead-acid batteries.
- Q:How does battery activation work?
- If you are talking about dry batteries, that is, to add sulfuric acid can use the battery (commonly known as water bottles), then it is because the long-term storage so that a high degree of oxidation of the negative board, plus acid will be a high temperature, Low, you can add acid in the pool after the addition of a small current for a long time to charge, you can solve. Generally with 0.05C charge to 3 times can be.
- Q:How to repair the battery?
- Maintain the battery before, first of all to clean up the battery appearance of the dust, remove the terminal above the stain and corrosion.
- Q:What is a maintenanceable battery?
- It also has a shock, high temperature, small size, self-discharge characteristics. Life is generally twice the ordinary battery.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Lithium-ion Battery Energy Storage System CFE Replacement LFP S
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 pc
- Supply Capability:
- 10000000 pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords