High Voltage 11KV Variable Frequency Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pc/year pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
General of High Voltage 11KV Variable Frequency Drive
High Voltage 11KV Variable Frequency Drive is designed to be highly reliable with high-performance, yet easy to use.It can satisfy users' need for changing the speed of fans or pumps,as well as improve the productivity.
The series are compatible with all types of three-phase medium voltage asynchronous motors.
Application Filed of High Voltage 11KV Variable Frequency Drive
High Voltage 11KV Variable Frequency Drive can usually be applied in these fields:
Power generation: induced draft fans, forced draft fans, condensate exhausting pump, boiler feed water pumps, primary fan, secondary fan, circulating pump, mill fan, slurry pump, mill .
Metals: dusting fans, slurry pump, feeding pump, furnace fans, compressor, mill
Cement: fan, discharge fan, waste gas fan, dust collecting fan, dust removing fan, mill.
Oil & Gas: water injection pump, oil transfer pumps, air compressor.
Mining: Fans, media pump, circulating pump, gas pump, oil separating pump, compressor, lift, mill, conveyer, hoisting machine.
Water: water supply pump, circulating pump.
System Principle of High Voltage 11KV Variable Frequency Drive
Technology Data of High Voltage 11KV Variable Frequency Drive
3KV series Variable Frequency Drive
Model |
A03/050~A03/100 |
A03/100~A03/175 |
A03/175 ~A03/220 |
A03/220~A03/400 |
A03/220~A03/610 |
Capacity(kVA) |
250~630 |
630~900 |
900~1150 |
1150~2000 |
2000~3125 |
Rated output current (A) |
50~100 |
100~175 |
175~220 |
220~400 |
400~610 |
Motor power (kW) |
200~400 |
400~710 |
710~900 |
900~1600 |
1600~2500 |
Input frequency |
45Hz~55Hz | ||||
Rted input voltage |
3000V±10% | ||||
Input power factor |
0.95 (>20%load) | ||||
Efficiency |
0.96 with rated load | ||||
Output frequency |
0.5Hz~120Hz | ||||
Frequency resolution |
0.01Hz | ||||
Overload capacity |
120% 1 min, 150% immediately | ||||
Analogue input |
0~10V/4~20mA | ||||
Analogue output |
0~10V/4~20mA | ||||
Acceleration/deceleration time |
0.1~3000s | ||||
Digital output/input |
expanded according to requirement | ||||
Ambience temperature |
0~40℃ | ||||
Storage/transport temperature |
-40~70℃ | ||||
Cooling |
air cooling | ||||
Ambience humidity |
<90% without condensation | ||||
Altitude |
<1000 m | ||||
IP class |
IP20 | ||||
Size(mm)(W×H×D) |
3300×2480×1200 3900×2480×1200 |
4900×2480×1200 6000×2580×1200 |
6000×2580×1300 | ||
Weight (kg) |
3000 ~5000 |
5000 ~7300 |
7300~9200 |
6KV series Variable Frequency Drive
Model |
A06/050 |
A06/050~A06/080 |
A06/080~A06/100 |
A06/100~A06/170 |
A06/170~ A06/220 |
A06/220~A06/400 |
A06/400~A06/610 |
Capacity(kVA) |
≤500 |
500~800 |
800~1000 |
1000~1750 |
1750~2250 |
2250~4000 |
4000~6250 |
Rated output current (A) |
≤50 |
50~80 |
80~100 |
100~170 |
170~220 |
220~400 |
400~610 |
Motor power (kW) |
≤400 |
400~630 |
630~800 |
800~1400 |
1400~1800 |
1800~3250 |
3250~5000 |
Input frequency |
45Hz~55Hz | ||||||
Rated input voltage |
6000V±10% | ||||||
Power factor |
0.95(>20%load) | ||||||
Efficiency |
0.96with rated load | ||||||
Output frequency |
0.5Hz~120Hz | ||||||
Frequency resolution |
0.01Hz | ||||||
Overload capacity |
120% 1 min, 150% immediately | ||||||
Analogue input |
0~10V/4~20mA | ||||||
Analogue output |
0~10V/4~20mA | ||||||
Acceleration/deceleration time |
0.1~3000s | ||||||
Digital input/output |
expanded according to requirement | ||||||
Ambience temperature |
0~40℃ | ||||||
Storage/transport temperature |
-40~70℃ | ||||||
Cooling |
air cooling | ||||||
Ambience humidity |
<90%,without condensation | ||||||
Altitude |
<1000m | ||||||
IP class |
IP20 | ||||||
Size(mm)(W×H×D) |
3600×2480×1200 ,TD> |
3900×2480×1200 |
4200×2480×1200 5100×2480×1200 |
5200×2580×1200 |
6600×2580×1300 8700×2780×1400 | ||
Weight (kg) |
3500~4000 |
4000~5000 |
5000~6000 |
6000~8000 |
8000~14000 |
10KV series Variable Frequency Drive
Model |
A10/080 |
A10/080~A10/150 |
A10/150~A10/210 |
A10/210~A10/400 |
Capacity(kVA) |
≤1250 |
1250~2500 |
2500~3500 |
3500~6250 |
Rated output current (A) |
≤80Rated output current (A) |
80~150 |
150~210 |
210~400 |
Motor power(kW) |
≤1000 |
1000~2000 |
2000~2800 |
2800~5000 |
Input frequency |
45Hz~55Hz | |||
Rated input voltage |
10000V±10% | |||
Power factor |
0.95(>20%load) | |||
Efficiency |
0.96with rated load | |||
Output frequency |
0.5Hz~120Hz | |||
Frequency resolution |
0.01Hz | |||
Overload capacity |
120% 1 min, 150% immediately | |||
Analogue input |
0~10V/4~20mA | |||
Analogue output |
0~10V/4~20mA | |||
Acceleration/deceleration time |
0.1~3000s | |||
Digital input/output |
expanded according to requirement | |||
Ambience temperature |
0~40℃ | |||
Storage/transport temperature |
-40~70℃ | |||
Cooling |
air cooling | |||
Ambience humidity |
<90%,without condensation | |||
Altitude |
<1000m | |||
IP class |
IP20 | |||
Size(mm)(W×H×D) |
4500×2480×1200 |
5700×2480×1200 |
6800×2580×1300 |
10600×2580×1300 |
Weight(kg) |
3500~6000 |
6000~8000 |
8000~15000 |
15000~19000 |
- Q:How do I select a drive? Which brand is better
- ?11, the inverter drives the synchronous motor, compared with the power frequency power regulator, reduce the output capacity of 10% to 20%, the inverter's continuous output current is greater than the synchronous motor rated current and synchronous pull the current value of the unit value product. ????12, for the compressor, vibration and other torque fluctuations in the load and the hydraulic pump and other peak load case, if the motor in accordance with the rated current or power value of the inverter, then there may be due to peak current over-current protection Action phenomenon. Therefore, you should understand the frequency of the operation of the situation, select the maximum current than the maximum current output of the inverter. When the inverter drives the submersible pump motor, the rated current is greater than the rated current of the submersible pump motor because the rated current of the submersible pump motor is greater than the rated current of the normal motor. ????13, when the inverter control Roots blower, because of its large starting current, so select the inverter must pay attention to whether the capacity of the inverter is large enough. ????14, select the inverter, be sure to pay attention to whether the protection level with the scene to match. Otherwise the scene of dust, water vapor will affect the long-term operation of the inverter. ????15, single-phase motor is not suitable for inverter drive. Recommended Ampang letter converter, domestic brand, quality and stability, first-class service, trustworthy!
- Q:What is the frequency converter used to do, why some motor with the inverter?
- Speed control, there are speed requirements of the place are in the inverter
- Q:Will the laptop's power adapter is not the original good?
- See the adapter is suitable for notebook models to use, the following three conditions for reference: 1. The output voltage of the adapter is the same as that of the notebook. 2. Is the adapter's output current consistent with the notebook's requirements? (Or a little bit of the current is also not.) 3. The size of the joint is appropriate. (If the connector is too loose, will be bad, excessive fever.)
- Q:Is the laptop power adapter high temperature normal? Is there anything else?
- Summer heat is normal, as long as it is not the kind of hand touch on the bubble temperature, no problem
- Q:What is the laptop power adapter? Is it the battery?
- Notebook power adapter, of course, is not referring to the laptop battery.
- Q:Delta inverter reported CE4 reasons? Casually asked how many kinds of CE under a total
- Which model ah, CE alarm, it should be communication failure. CE4, it seems that should be written to the read-only address. You follow the inverter model, to the Delta website to download the corresponding manual, there are fault alarm instructions.
- Q:30 kW 6 pole frequency motor torque is how much
- 30 kW 6 pole frequency motor torque is how much 860. 1, the motor torque calculation Motor "torque", the unit is N? M (beef) 2, the formula is T = 9549 * P / n. 3, P is the motor rated (output) power unit is kilowatts (KW) The denominator is the rated speed n units are per minute (r / min) P and n can be found directly from the motor nameplate.
- Q:ABB frequency converter and the difference between domestic frequency converter
- Both the eyepiece and the objective lens are convex lenses with different focal lengths. The focal length of the convex lens of the objective lens is smaller than the focal length of the convex lens of the eyepiece.
- Q:The inverter control power is also the same, the pole is not the same as the motor 6 or 4 pole can be used?
- Can be used, their rated current is not the same, the need to use the inverter over-current overload protection and other parameters for the corresponding changes.
- Q:What is the IGBT? Our inverter IGBT fried,
- Name is the FET, the price of this thing is more expensive,
1. Manufacturer Overview |
|
---|---|
Location | Beijing,China |
Year Established | 1998 |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | TIANJIN |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | ENGLISH,CHINESE |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
High Voltage 11KV Variable Frequency Drive
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 1PC pc
- Supply Capability:
- 10,000pc/year pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords