• XLPE/PVC insulated PVC sheath underground power cable System 1
  • XLPE/PVC insulated PVC sheath underground power cable System 2
  • XLPE/PVC insulated PVC sheath underground power cable System 3
XLPE/PVC insulated PVC sheath underground power cable

XLPE/PVC insulated PVC sheath underground power cable

Ref Price:
get latest price
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
20000 m/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

Specifications

1.PVC insulation CU/AL conductor 
2.multi core armour cable 
3.medium voltage 0.6/1KV 
4.good quality low price 
5.OEM available

1.Standard: GB/T12706/IEC60502 or according to customer’s requirements

2.Voltage Rated:  0.6/1KV, 6KV, 8.7/15KV, 12/20KV, 26/35KV

3.Application: It's applies to electrical power transmission and distribution lines with AC rated voltage up to and including 0.6/1KV. For outdoor and indoor installation in damp and wet locations , laid directly in the ground. 

1,The general type cable are suitable for rated AC voltage 0.6/1KV and below electric lines without flam-retardant or fire-resistance requirements.

2,The flame-retardant type cables are not easy to burn or their flame propagation is limited only in a certain length. . These cables are suitable for high installation density places like power station, subway, tunnel, high-building, large industrial enterprise, oil field and main etc.

3,The fire-resistant cables can not only operate in normal condition, but also can operate in fire during a certain time. These cable are suitable for power station, subway, high human density places where having fire-proof and fire-fight requirements.

4. Operating Features

1, Max .Long-time operating temperature of PVC insulated cable is 70°C

Max .Long-time operating temperature of XLPE insulated cable is 90°C

2.Installing temperature of cable should not be less than 0°C

3, Max short-circuit temperature is not exceed 250°C, Not more than5 Sec.

4,Ambient temperature of installation is not lower than 0°C

5,With good chemical stabilities, such as resistance to acid, alkali, salt, oil and organic solvent and flam-retardant..

6,With light weight, good character, easy to installation and maintenance.

5.Norminal cross section size of conductor: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2  630mm,

6.Cores available: Single core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores, 4+1 cores.

7.This series of Copper Cables  include models as below:

Type

Description

Cu Core

Al Core


VV

VLV

Cu/Al core power cable with PVC insulation PVC sheath

VY

VLY

Cu/Al core power cable with PVC insulation PE sheath

VV22

VLV22

Cu/Al core, steel-belt armored power cable with PVC insulation PVC sheath

VV32

VLV32

Cu/Al core, thin-steel-wire armored power cable with PVC insulation PVC sheath

VV62

VLV62

Cu/Al core, non-magnetic-steel-belt armored power cable with PVC insulation PVC sheath

VV72

VLV72

Cu/Al core, non-magnetic-steel-wire armored power cable with PVC insulation PVC sheath

YJV

YJLV

Cu/Al core power cable with XLPE insulation PVC sheath

YJV22

YJLV22

Cu/Al core, steel-belt armored power cable with XLPE insulation PVC sheath

YJV32

YJLV32

Cu/Al core, thin-steel-wire armored power cable with XLPE insulation PVC sheath

YJV62

YJLV62

Cu/Al core, non-magnetic-steel-belt armored power cable with XLPE insulation PVC sheath

YJV72

YJLV72

Cu/Al core, non-magnetic-steel-wire armored power cable with XLPE insulation PVC sheath

8.Specification Size and Technical Data:

Core number

Nominal Section(mm²)

D.C.Resistance in 20 °c(Ω/km)

 

O.D.(mm)

Reference Weight(Kg/km)

CU

AL

Cu

Al

 

 

 

3 core

1.5

17

10.7

141

2.5

23

17

11.5

180

134

4

30

23

13.6

255

183

6

39

30

14.9

341

228

10

54

41

16.3

470

285

16

71

55

19.6

697

363

25

99

76

23.4

1049

568

35

120

92

25.8

1370

702

70

186

143

28.7

2350

1031

95

227

175

32.8

3144

1355

120

262

203

34.9

3882

1624

185

352

272

43.9

5945

2464

240

420

324

49.2

7647

3132

 

 

 

 

 

 

3+1 core

3×4+1×2.5

31

23

14.2

289

202

3×6+1×4

40

31

15.8

386

262

3×10+1×6

54

42

17.3

548

329

3×16+1×10

72

56

20.5

793

408

3×25+1×16

98

75

24.6

1196

608

3×35+1×16

122

94

26.9

1518

744

3×50+1×25

153

118

27.9

2032

931

3×95+1×50

231

178

35.1

3683

1583

      3×120+1×70

267

207

37.9

4617

1924

3×150+1×70

315

242

41.7

5563

2306

3×185+1×95

362

279

46.4

6929

2854

 

9.Construction:

No: of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

About us:

Our company is specialized in conductor ,such as: AAC, AAAC, ACSR/AW, ACS, ABC CABLE, PVC insulated Wire and flexible Eire, PVC insulated Power cable, XLPE insulated power cable


Q: I want to put a poe switch into the patch panel and power a few runs throughout the office. Can the end users use the drop as a standard way to plug into a computer or add a switch if they need to split the internet? What if they want to add their own POE switch at the end of the drop?I can't beleive I haven't seen this question asked already! Anywhere on the intternet!thanks for answering
spliters okorder /
Q: i bought a car from some guy..he had 2 amps but he took out one...he had the power cable running from one amp to the other. i just recently bought another amp and i was wondering if its safe to do this.he said it was working fine..he was powering 2 10 subwoofers..thats what im planning to do
its safe but its better to run 2 separate wires due to you are wanting to use more power and one wire has a max load that it can handle...you run 2 and you will have more power to each amp
Q: I have a Dell Latitude D505. I do not need comments on whether I have a good laptop or not. That's not the point.I heard a tiny pop sound, and after that, my laptop is not recognizing the power cable. I don't think it's the cable. I've tried restarting the computer. Any suggestions?
Something broke and you will not fix your problem here. Only a computer tech can help you now.
Q: What is the difference between VV22 and VV62?
Copper core conductor PVC insulated PVC sheathed double steel tape wrapped armored type power cable copper conductor PVC insulated PVC sheathed non-magnetic metal armored power cable difference is the type of armor material
Q: I noticed many of our server cables are thicker than the standard ones for a desktop PC. Would any power cable work, regardless of gauge? I want to use shorter server power cables for cable management purposes, since some of our server cables are over 10-15 ft. in length and only need 3 ft. or so.
You okorder /
Q: 3 (WDZBN-YJV-4x240 + 1x120) cable how to interpret
Should be such a model it WDZB-YJV0.6 / 1kV4x240 + 1x120 power cable halogen-free low smoke flame retardant B grade refractory cross-linked polyethylene insulation - polyethylene jacket 0.6 / 1kV power cable, 4 core 240mm + 1 core 120mm copper Core cable.
Q: I'm installing my car audio system in the morning. I have a 650w 4 channel amp for my four interior speakers and a class D monoblock amp for my sub.I have an 8awg wiring kit. If I split that to use it on both amps, it would end up at 16awg going to the amps. Is this thick enough for my setup?
1. We can't answer without knowing more about your amplifiers. 650w 4 channel doesn't tell us anything useful, because the power rating may be a peak number that's only good for marketing, and you didn't tell us anything about the monoblock amplifier at all. Give us brand and model numbers and we might be able to help. 2. If I split that to use it on both amps, it would end up at 16awg going to the amps ....no. That's now how it works. (I'm not sure how you envision splitting the wire to make two wires that are half the size; are you cutting it down the middle with a razor?) You can use a distribution block to connect both amplifiers to the same main power wire, but you don't have to go to a smaller wire out of the d-block: you can run 8-gauge wire from the battery to the distribution block, then more 8-gauge from the d-block to each amp. 3. Even if you did cut the 8-gauge wire in half, a wire half the size of 8-gauge isn't 16-gauge. It's 11-gauge. If you put six 16-gauge wires together, you'd get a wire that's a little smaller than 8-gauge. Please edit your question with the brand and model numbers of both amplifier, along with the estimated length of the wire run (ie, how many feet of wire do you need to go between the amps and the battery?) Then we can tell you what gauge wire you need. Edit: thanks for the update. Based on the information about your amplifiers, I don't think you should run both of them from the single 8-gauge wire. I'd switch to a 4-gauge dual amp kit, or you can buy a second 8-gauge kit and run each amp with its own power wire to the battery rather than sharing a single wire.
Q: Well I guess the more general question is:Are quot;twin power cablescompatible with 12v accessories and motorcycle batteries to make a safe running circuit?
This is absolutely possible. I would be careful about the weight of cable you use, ensure that it can carry the amp rating of the accessory you want to power from the 12v accessory socket. For example if you're powering a heated vest these can be rated at up to 25 amps. Maplin have a good range of cables at various A ratings. I would also advise you crimp and heatshrink rings onto the cables that you can clamp onto the battery terminals. The Anchor ones are excellent, but Maplin will stock a range of options. You may want to think about wiring an inline fuse, and/or a switch to prevent overheating, and to protect your battery. Hope this helps.
Q: I need to change a cable that goes from public power lines to power meter because its skin/protecting shield is peeling off. What happens is that I need to fix this issue as soon as possible but do not know what kind of cable should be used for repair. I would greatly appreciate your help. Thank you!
examine the entire load modern-day score of the motor then length your cable for a voltage drop interior the wires of decrease than 5%. With that long of a run the voltage drop attention would be greater stringent than the optimal modern-day for the cord gauge.
Q: I am getting a new gaming computer for Christmas with a 700 watt, 12.5 AMP (I think) power supply. I have two power cords for computers on my shelf, but my dad is worried that a standard power cable won't properly power my computer. Do I need to get a more powerful cable? If so, please send a link to where I can buy one, I have been searching but only found standard ones. Thank you.
A standard cord will work, that is not 7.5 amps it is 700w/115V=6.08amps. for 15 amps you need 14guage wire and for 20 amps 12 gauge 30 amps 10 gauge,and so on, you may need to be aware of how many other things you plug in to that circuit, such as a tv in another room or even another computer because you may have more than one room on the sam house circuit

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches