Various Types of XLPE Insulation Power Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Various Types of XLPE Insulation Power Cable
Quick Information
1.Voltage: 1kv to 35kv
2. ISO, CCC Certificate
3. 22 years producing experience
4.Professional service
We can customize various types of cable in accordance with your requirements
XLPE /PVC insulated power cable
Mode and name
We can produce 1kv up to 35kv power cable
Specification
XLPE insulated power cable 0.6/1kv | |||||||||||
norminalsectional area | insulati-on thicknes | sheath thickness(mm) | overal diameter of cable (mm) | D.C resistance of conductor(km) | current rating | ||||||
in air(A) | direct in soil(A) | ||||||||||
cu | Al | cu | Al | cu | Al | ||||||
1×1.5 | 0.7 | 1.5 | 6 | <=12.1< span=""> | <=12.1< span=""> | 30 | 25 | 45 | 35 | ||
1×4 | 0.7 | 1.5 | 7 | <=7.41< span=""> | <=7.41< span=""> | 45 | 35 | 60 | 50 | ||
1×6 | 0.7 | 1.5 | 7 | <=3.08< span=""> | <=4.61< span=""> | 55 | 45 | 70 | 55 | ||
1×35 | 0.9 | 1.5 | 12 | <=0.524< span=""> | <=0.868< span=""> | 175 | 140 | 190 | 150 | ||
1×50 | 1 | 1.5 | 13 | <=0.387< span=""> | <=0.641< span=""> | 210 | 170 | 225 | 180 | ||
1×70 | 1.1 | 1.5 | 14 | <=0.268< span=""> | <=0.443< span=""> | 270 | 215 | 280 | 225 | ||
1×95 | 1.1 | 1.5 | 16 | <=0.193< span=""> | <=0.320< span=""> | 340 | 275 | 335 | 270 | ||
1×120 | 1.2 | 1.5 | 18 | <=0.153< span=""> | <=0.253< span=""> | 400 | 320 | 380 | 305 | ||
1×150 | 1.4 | 2 | 21 | <=0.124< span=""> | <=0.206< span=""> | 460 | 370 | 425 | 340 | ||
1×185 | 1.6 | 2 | 23 | <=0.0991< span=""> | <=0.164< span=""> | 530 | 415 | 480 | 375 | ||
1×240 | 1.7 | 2 | 25 | <=0.0754< span=""> | <=0.125< span=""> | 625 | 490 | 555 | 435 | ||
… | |||||||||||
3×1.5 | 0.7 | 1.5 | 10 | <=12.1< span=""> | <=12.1< span=""> | 25 | 25 | 30 | 30 | ||
3×2.5 | 0.7 | 1.5 | 11 | <=7.41< span=""> | <=12.1< span=""> | 30 | 25 | 35 | 30 | ||
3×4 | 0.7 | 1.5 | 12 | <=4.61< span=""> | <=7.41< span=""> | 40 | 30 | 50 | 40 | ||
… | |||||||||||
Attention: We can provide more info than above data, if needed.The above are just some examples. |
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 D times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant.
Type and Specifiction
PVC Insulation Electric Cable
TYPE | Description of Cable
| Main Applications
| |
CU core | AL core | ||
VV | VLV | Copper/Aluminium core,PVC insulated,PVC sheathed power cable | Non-armoured PVC cable are suited for laying indoors,In cable trench,On cable racks and in pipes. Unable bear external pressures and tensions. |
VY | VLY | Copper/Aluminium core,PVC insulated,PE sheathed power cable | |
VV22 | VLV22 | Copper/Aluminium core,PVC insulated,steel tape armored,PVC sheathed power cable | Steel-tape armoured PVC cables are suited for vertical burial.Can bear moderate positive pressures,Unable bear tension forces. |
VV23 | VLV23 | Copper/Aluminium core,PVC insulated,steel tape armored,PE sheathed power cable | |
VV32 | VLV32 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PVC sheathed power cable | Thin steel wire armoured PVC cables are used in case of great difference of levels or vertical installation and Can do vertical burial.Can bear moderate positive pressures and tension forces. |
VV33 | VLV33 | Copper/Aluminium core,PVC insulated,thin steel wire armored,PE sheathed power cable | |
VV42 | VLV42 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PVC sheathed power cable | Thick steel wire armoured PVC cables are suited for vertical installation and can be laid water or sea-bottom.Can bear greater positive pressures and tension forces. |
VV43 | VLV43 | Copper/Aluminium core,PVC insulated,thick steel wire armored,PE sheathed power cable |
Picture
- Q: hi,i was wondering...can battery powered tv have cable? or do the battery powered tv not need cable? my niece likes spongebob so if she does come over she can watch it....but i just want to know before i buy it...thanks...P.S:so do they already have all the cable shows?or they dont?and if they dont do you have to put cable....and if they cant....then i shouldn't buy it?
- You'll have to plug it in to the cable, but yes that will work. What you have to check, is what kind of connection it has. You also MAY have to plug it into a cable box or VCR to get it to work. - 17R3W
- Q: should you run RCA cables and power next to each other?
- you can but its always best to run them apart for the least possible interference.
- Q: I'm referring to the older models of both the PS2 and PS3, not the slim models.
- Controllers, yes, you just need a special adapter. Power cable, absolutely not, since the PS3 Fat uses a 3-prong power cable like what computers use and the PS2 uses a completely different kind with only 2.
- Q: I'm only asking this on here out of interest, this is not homework. I want to know how to calculate exact distances between to poles connected at the top by a cable. The length or height of the objects are not important to me, but if you must use an example please do so. So I want to know what formulas to use, what variables in those formulas mean, and how the slope of the cable will affect the distance. For example, if two poles have a distance between them of 0, and the cable extends 100, it would not mean that the drop of the cable (called a catenary?) would be 50, (it's misleading because you would think that since the distance between the two poles is 0, the cable would drop 50 and rise 50. But this is not taking into account the slope it has to take at the bottom of the catenary. It must lose some drop (perhaps to 48 or 49) in order to bend and rise back up...I want this out of my head, it's bugging me that I can't figure it out.
- No sign can commute faster than the fee of sunshine (neglecting tachyons, that have in no way been pronounced interior the genuine international, yet in concept can in no way slow all the way down to or commute under the fee of sunshine). The ropes and poles could flex because of the fact the sign traveled alongside them. because of the fact that they'd not flow right this moment, the sign could commute at a speed nicely under c. right that's a version on the pole concept. think you have 2 very long poles crossed at an attitude. The poles are rotating from their crossed orientation to alter into extra parallel. the factor P the place the poles bypass will commute down the poles as they attitude parallel, shifting faster and faster. Can the action of P exceed the fee of sunshine? particular it could! P would not have any actual manifestation and for this reason no mass; for this reason its action isn't constrained with the aid of relativity. in spite of the undeniable fact that, if P did have mass -- as an occasion, if there became a hoop around the crossing factor -- then the poles could be compelled to flex because of the fact the relativistically increasing mass drew further and further ability from them. * To Michael under: Einstein's particular concept of Relativity states that it could consume an limitless quantity of ability to strengthen up any particle with mass to the fee of sunshine. So that is impossible to strengthen up even an electron to the fee of sunshine, regardless of the certainty that scientists can get very very close now. Photons have not have been given any mass so as that they commute on the fee of sunshine and easily on the fee of sunshine (and is the reason why every person measures an identical fee for c). Tachyons have an 'imaginary' mass (a dissimilar of the sq. root of -a million) and so as that they can't commute as slow or slower than mild... merely faster!
- Q: I had gave my amp a 16 volt input, then there was a spark which came from fuses that got burnt. I then replaced the fuses, rewired it nd gave it a 12 volt input it came on and went on protection. So i left it aside and after a few days i tryd connecting it again but this time it came on and it was burning the power cables no matter what guage wire i used. Any idea why its doing that?
- It's a 12 volt DC car-type amp ? Sounds like it's got a short inside. But, unhook all the other wires, all the speaker leads imputs, except for the power the ground. Have a fuse in one of those two leads, turn the amp OFF, hook up it. If the fuse pops right away, then odds are it is now a piece-'o-junk. If it sits okay, turn it on, with no volume. Again, if the fuse goes, trash it. If it holds okay, hook up ONE of the speakers give it a little volume. Even without an imput, you should be able to hear a bit of static, which means it's working okay. Turn it off try another speaker....etc etc
- Q: Single single 10kV power cable with copper shield can wear steel pipe? What will be the impact?
- Do not have to be so troublesome, such a phenomenon even encountered, is the basement of the air defense, similar to the landlord said the phenomenon can be taken as follows: . first with linen live wire and casing blank. . filled with asbestos cement and compaction, the surface concave sleeve 3-4 cm. . with plugging the king (5 yuan / bag) add water and mix well, smear the surface to smooth. . the work is completed, do not hurt the core and the practice proved no leakage within two years.
- Q: what the size of power cable 3 core for motor 18.5 Kw with star dalta starter?
- Full load current is 32 amps,phase current is 18.4 amps Hence 3 core 15 sq.mm power cable is req.or 3 core 6 sq.mm 2 nos of cables req. to connect motor to starter.
- Q: my sub came loose and started sliding around in my boot until the power cable got ripped out of the amp while i was driving at it was on. When i tried putting the power back in it just blew the fuses, so i bought some more, and they blew as soon as they went in as well, and one of the bits of metal melted putting one it! strathfield said its 45 for an inspection, plus the cost of fixing it. any ideas whats wrong with it and if i can fix it myself??cheers.
- Check your wiring, you have a wire cross if it bows when turned on. Also you might be using the wrong fuse, what is the rating of your amp (15 amps = 1800 watts). Or you are diving the amp too hard and prevent it from damage and blowing the fuse. Upgrade the fuse to 25 amps and see what happens.
- Q: Well I guess the more general question is:Are quot;twin power cablescompatible with 12v accessories and motorcycle batteries to make a safe running circuit?
- This is absolutely possible. I would be careful about the weight of cable you use, ensure that it can carry the amp rating of the accessory you want to power from the 12v accessory socket. For example if you're powering a heated vest these can be rated at up to 25 amps. Maplin have a good range of cables at various A ratings. I would also advise you crimp and heatshrink rings onto the cables that you can clamp onto the battery terminals. The Anchor ones are excellent, but Maplin will stock a range of options. You may want to think about wiring an inline fuse, and/or a switch to prevent overheating, and to protect your battery. Hope this helps.
- Q: I have a Raidmax 730w power supply, and its modular. there is only one plug in for a 6 pin, and the cable has 2 different 6 pins on the same cable. Will this cable be able to run 2 different video cards running XFire? or will is also be able to run say a 6870 that requires 2 6 pin connectors?
- You should be able to feed two cards that each require 1 6/8 pin PCI-E power source... or 1 card that requires 2 6/8 pin PCI-E power source. A cable with 6 pin provides 75W power to the card. With the 75W available on the PCI-E x16 slot, that would be a 150W supply. 2 6 pins will up the available wattage to 225W. Cards that require a 6 pin and 8 pin are 300W cards. Your cable/PSU port is designed to provide any of those combinations of power to the videos card(s).
Send your message to us
Various Types of XLPE Insulation Power Cable
- Loading Port:
- China main port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 200 m
- Supply Capability:
- 20000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords