Application

 

Widely used in the fields of post office,store,elevator,hospital,school,publishing house and stock exchange where normal voltage is in need,and also can be used in the factories of large and middle-scale industrial and mining corp,it is very much suitable for some important devices and supporting single machine.

 

Input voltage

Three-phase four-line system phase voltage:220±20%

 

line voltage:380±20%,or phase voltage:220±30%

line voltage:380±30%(can be selected.Please specify when ordering)

Single-phase:220±20% or 220±30%(can be selected.Please specify when ordering.)

 

Output voltage

Phase voltage:220V Single-phase:220V Line voltage:380V

Output voltage accuracy

1-5%(can be adjusted)Frequency:50HZ/60HZ

Efficiency

≥98%(Power grade over 50KVA)

Ambient temperature

-10~+40°C

Insulation resistance

≥5MΩ

Electric intensity

The voltage for electrical strength and power frequency sinusoidal is 2000V without breakdown and flash over when lasts 1minute

Overload Capacity

It can last 1 minute at the rated current of two times

Wave form Distortion

No additional waveform distortion

Protective function

it offers the protections against over voltage,over current,phase shortage and phase-sequence(The single-phase offers no protection against the phase shortage and phase-sequence)and mechanical failure

Response speed

≤1s(in the condition that the external voltage changes is 10%)

 

Q: Why should lighting transformers be used in factories and mines?
But in many cases, such as mines and machinery, the voltage is too high and unsafe. The lighting transformer is then used to reduce the voltage to the so-called "safety voltage""
Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
You must know the quantity and power of the lamp to determine the transformer
Q: Why is the two side of the lighting transformer grounded?
Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
Q: The difference between lighting transformers and control transformers
In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
Q: Is the substation separate from the power and illumination transformer?
The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
Q: 3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
Pure resistive load, the power factor is 1.3 *100W=300W, is required for the capacity of the transformer.
Q: How is the lighting power of the 380V transformer calculated?
With a light bulb with 4KVA load, the premise of the distance can be Mrs. face light bulb, dark can light the best load, 3KVA bulb brightness
Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
Q: Why can't autotransformer be used as transformer for safety lighting?
The transformer of the lighting circuit is a step-down transformer (general input 10kv., 220V). The first coil of the autotransformer is shared and connected together
Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
If you share a power line, you must calculate the current and select the appropriate wire to ensure normal pressure drop and safe use.
We have set up stable trading cooperation with customers from the Middle East, South Africa, North America, Europe and other areas worldwide. We gain a good reputation among customers and lay solid foundation for our development. And we believe that we can be your faithful friends and reliable partner forever.

1. Manufacturer Overview

Location Shanghai, China
Year Established 2008
Annual Output Value US$50 Million - US$100 Million
Main Markets South America
Eastern Europe
Southeast Asia
Africa
Oceania
Mid East
Eastern Asia
Western Europe
Central America
Northern Europe
Southern Europe
South Asia
Domestic Market
Company Certifications CE

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Shanghai Port,Ningbo Port,Guangzhou Port
Export Percentage 81% - 90%
No.of Employees in Trade Department 6-10 People
Language Spoken: English, Chinese, Spanish, Arabic, French, Russian
b) Factory Information
Factory Size: 3,000-5,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords