Online UPS Power Supply 1KVA, 2KVA,3KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Units pc
- Supply Capability:
- 5000 Units per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application:
T Series 1KVA~3KVA High frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, ATM and so on.
Key Features:
LED Indicators display Detailed Real-Time UPS Status and parameters.
Set Output Voltage, Frequency parameter and bypass function on the display.
Advanced MCU microprocessor control technology, ensure long life reliability.
Wide input voltage range, Zero transfer time
Excellent Protection against over voltage, over load, over current, over charge and so on.
Input L and N lines reverse wiring detection, Auto start when AC back.
DC start function, Input PFC revise function.
Humanization bypass output, can be adjustable.
Smart RS232 communication with monitoring software
Intelligent slot available for AS-400 Dry contact and SNMP card Remote control
Available to work with generators.
Lightning, surge, short circuit, Network/fax/modem surge protection
Basic tech datasheet
UPS Model | EX1K | T1K | EX2K | T2K | EX3K | T3K | |
Capacity | 1000VA/700W | 2000VA/1400W | 3000VA/2100W | ||||
Input | Voltage | (115~300) VAC | |||||
Frequency | 46~54Hz/56~64Hz (Adjustable via LCD panel) | ||||||
Output | Voltage | 220/230/240 (1±1%) VAC (Adjustable via LCD panel) | |||||
Frequency | 50/60Hz (Adjustable via LCD panel) 50Hz AC Mode: Follow AC Mode(AC Range 46~54Hz); Battery Mode:50Hz (1±0.2%) 60Hz AC Mode:Follow AC Mode(AC Range56~64Hz); Battery Mode: 60Hz(1±0.2%) | ||||||
Output Wave Form | Sine Wave | ||||||
Back-up Time | Full Load | ≥5′ | ≥9′ |
| ≥5′ |
| |
Half Load | ≥14′ | ≥21′ | ≥15′ | ||||
Battery Nominal DC Voltage | 36VDC | 96VDC | |||||
Transfer Time | 0ms | ||||||
Overload Capacity | 110%~150% maintain 30s then turn to bypass output, over 150% maintain 300ms | ||||||
Communications | RS-232+Intelligent Slot | ||||||
Environment | Temperature | 0C~40C | |||||
Humidity | 15%~90% | ||||||
Dimensions (W*D*H)mm | 400*145*220 | 460*192*348 | 460*392*348 |
- Q: How many power illuminator can 5Kva 36V transformer drive?
- By formula: P=UI COSAThat is, the transformer capacity is S=UI=5KVAHow big is the COSA?. Look, what kind of illuminator do you use?. Usually take 0.8-0.9It can be calculated that P is about 4KW-4.5KW (general lighting)
- Q: What type of low voltage transformer should be adopted for safety lighting power supply?
- We have produced many low voltage lighting transformers, such as outdoor waterproof, high-power stage lighting, as well as indoor small power transformers, customer response, but also good! For example, Guangzhou Color Art Lighting Co., Ltd., before them, our reputation is good!
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- You must know the quantity and power of the lamp to determine the transformer
- Q: Why is the two side of the lighting transformer grounded?
- Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- I don't know how much the output voltage of your transformer is, but the internationally accepted voltage below 36V is the voltage that is not harmful to the human body
- Q: How many A leakage protection switches are used in 5000VA lighting transformers?
- According to the working principle of the protector, it can be divided into three kinds: voltage type, current type and pulse type. The voltage protection device is connected to the transformer neutral point and the ground, when the electric shock when the neutral point voltage offset to the real estate, in order to make the action to protect the power off, but because it is the protection of the transformer low voltage network, cannot be classified protection, so the power range is large, frequent moves, so has been eliminated. The pulse current protector is a sudden change in the phase and amplitude of the three-phase unbalanced leakage current when an electric shock occurs, which is used as an action signal, but also a dead time. The current type current leakage protector is widely used, so the protector of current type is mainly introduced below.
- Q: How is the lighting power of the 380V transformer calculated?
- Special transformer power transformer (electric furnace transformer, rectifier transformer, power frequency test transformer, voltage regulator, transformer, audio, mine variable frequency transformers, high frequency transformer, transformer, instrument transformer, impact power transformer, reactor, mutual inductor etc.) circuit with T symbol number. For example: T01, T201 etc.
- Q: Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
- A set of coils in a autotransformer having one tap that does not function as a barrier. Or, the two sets of coils are attached.
- Q: Lighting, lights, transformers, bulb brightness is too low, what's the matter?
- Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
- Q: How to calculate the rated capacity of small transformers for lighting purposes?
- If the flow of large capacity motor starting current and welding machine, large current flows in a short period of time in the load even when the power equipment capacity can withstand current flow in a short time, but due to a voltage drop excitation electromagnetic switch relief, the motor can not start, damaged or the undesirable phenomenon of welding. Therefore, the voltage drop rate should be calculated as less than 10% of the supply voltage, as calculated below.
1. Manufacturer Overview
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b) Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Online UPS Power Supply 1KVA, 2KVA,3KVA
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 5 Units pc
- Supply Capability:
- 5000 Units per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords