Six Stocks Twisted Wire

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
100 M.T. m.t.
Supply Capability:
10000 M.T. Per Month m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Specifications of Six Stocks Twisted Wire

1. Brief Introduction

Six Stocks Twisted Wire is known black oil iron wire or black annealed wire. The soft annealed wire is more economic than the Cold drawing hard wire for making nails.Black annealed wire is mainly processed into coil wire, spool wire or big package wire. Or further straightened and cut into cut wire and U type wire. Black iron wire is mostly used in construction or used as tie wire or baling wire in building, parks and daily binding.

2. General Specifications

Material High Quality Low Carbon Steel Q195
Finish Annealed
Type 2,3,4,5,6,or 7 pcs

Wire Diameter

BWG35 - BWG6 (0.2mm - 5.0mm)
Tensile Strength 300 - 500N/MM2
Elongation 15%
Coil Weight 4.5kg, 25kg, 50kg, 100kg, 200kg (or in according to your requirement)
Packing Oiled or not, Wrapped with PE film inside, outside pvc woven cloth or hessian cloth
Other sizes can be made as your request.

3. Detailed Specifications

Wire diameter

Strength

Package

Weight

Application

0.16mm-0.6mm

30-40kg

Coils of spools

2-100kgs

Binding wire for Christmas trees 

or other application

0.6mm-5.0mm

30-40kg

Big package

100-800kgs

0.16mm-0.6mm

60-70kg

Coils of spools

2-100kgs

0.6mm-5.0mm

60-70kg

Big package

100-800kgs

4. Information AboutBlack Annealed Six Stocks Twisted Wire 

Black Annealed Six Stocks Twisted Wiregets its name from its plain black color. Soft annealed wire offers excellent flexibility and softness through the process of oxygen free annealing. Annealed wire is obtained by means of thermal annealing, endowing it with the properties it needs for its main use - setting. This wire is deployed both in civil construction and in agriculture. Hence, in civil construction annealed wire, also known as burnt wire is used for iron setting. Annealed wire does not usually have any type of protective lining, paper or plastic. It is stored in coils or spools of a varying weights 

5. Some specialized name of Six Stocks Twisted Wire:

1X6 strands Black Annealed Twisted Wire, soft annealed wire, soft annealed black wire, soft annealed black iron wire, soft annealed black binding wire, black metal wire, oiled soft black wire, black wire manufacturer.

Factory

 six stocks twisted wire

Product & Packing

 six stocks twisted wire

Delivery

 six stocks twisted wire

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Some wire connects from a pole to point on the ground at an angle of depression of 80º. On the ground, the?
Wire length = 4.5' / cos 80 degrees = 25.91 feet Distance up the pole to where the wire is connected = 4.5' (tan 80 degrees) = 25.52 feet
Q:What do i do with this wire?
The remote wire is for the remote turn on for the amp. It connects to the blue/white wire from the head unit (aftermarket) to the REM terminal on the amp. If your using a stock head unit, you can run the fused (1 amp, added to the blue wire from the fuse panel) blue wire tapped from a fuse that only has power when the car is on to a switch. From the other side of the switch run the same blue wire to the REM terminal on the amp. This allows for full control and you never have to worry about forgetting to turn off the amp.
Q:what are the colored wires to wire up a trailer harness?r=1259029257?
you need to buy the harness for that particular truck, there's a plug already there for it, if you start hacking into wires you'll have more problems than you can believe. and I'm not going to explain it here, just trust me, there like $20 bucks and will save you a world of headaches.
Q:Which is the hot wire in nob and tube wiring?
Get a basic induction type tester tester. There is no theoretical live and neutral in knob and tube wiring. Wires were put where ever. Switches were put on either wire etc. The same type and color wire is used by both live and common.The only way to tell is to test.
Q:120/240 30 amp.wiring for generator to home?
You okorder.com/... made for your panel, it requires a little more electrical experience to install, and the parts are specific to each installation. It costs just a little more, but gives you the option of feeding any circuit in your panel that your generator can handle. The cord you need would be #10 awg, the 120 and 240 designation indicates you will need a neutral, two hots and a ground, so it would be a 4 wire cord.
Q:1985 SS Monte Carlo engine wires?
I have an '84 Monte SS and wanted the same thing. Here's what I have: the 2 wires that come from the harness and go to the starter (1 Positive, 1 S terminal), oil gauge wire, temp gauge wire, the alternator wires, the wire going to the distributor cap, and the tach gauge wire going to the distributor cap. That's pretty much it, as well as your battery cables, and spark plug wires. You really don't need to do or add anything as long as it runs and everything works that needs to work, it'll be fine. I'm going by memory, so if I forgot something I apologize, but that's the best of my recollection right now. If you have anymore questions you can email me.
Q:Solid wire joints and splices?
Electrical Splices And Joints Pictures
Q:what is the wire for 100A and 200A?
wow,if this is the question,no offense,you need to hire a electrician also you can not use 90c rating unless lugs or breaker has a 90c rating.
Q:WHY WOULD A LARGER WIRE HAVE LESS RESISTANCE?
Increasing the diameter of a wire while maintaining a constant density is equivalent to connecting another wire in parallel with the present wire. Each wire contains a certain end to end resistance. The total equivalent end to end resistance of two wire resistors connected in parallel is always less than resistance value of the wire with the smallest end to end resistance. Another way to look at it. The larger the wire the greater the cross sectional area. The greater the cross sectional area of a wire the greater the number of parallel paths the current can take. The more parallel current paths available from one end of a wire to the other the less the overall resistance of the wire will be. You stated There is 3 Volts going through each wire, to power your 1 Volt LED. If this is true then you must have a resistor of roughly 100 Ohms that is dropping 2 Volts connected between the 3 Volt source and the 1 Volt LED. Either the 3' wide wire or the .3 wire would work fine in this application. The .3 wire would be a tad less cumbersome than the 3` wire I might add. Response to additional details: Conductance is the reciprocal of resistance and is independent of the applied Voltage. More length of a given wire would mean more resistance. More cross sectional area of a given wire means less resistance. Any wire has resistance but the conductor wire resistance itself in an LED circuit is of no consequence I believe.
Q:2001 chevy blazer wiring harness?
For the best answers, search on this site https://shorturl.im/avPjM It may not work can't remember for sure but, I think the 01 is Drive By Cable (DBC) throttle body and the 03 is Drive By Wire (DBW). You can check by looking at the throttle body. If the throttle you have has a cable to operate it the 03 harness will not work. If the throttle body has an electrical plug then the harness will work. All plugs and connectors are the same except, the 01 has no plug for the throttle body and the 03 harness has one. Also there are connections for the throttle position sensor on the 01 harness. Anyhow, if you have the electric throttle then yes it will work.
NEW AGE ,we are a factory which is specially in glavanized wire, razor wire, barbed wire etc.

1. Manufacturer Overview

Location Hebei, China
Year Established 2004
Annual Output Value Above US$ more than 10,000,000
Main Markets U.S.A., Australia, Mexico, Canada, Japan and Korea s.,etc
Company Certifications ISO9001:2000

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Tianjin
Export Percentage 70%
No.of Employees in Trade Department less than 50 People
Language Spoken: English; Chinese;
b)Factory Information  
Factory Size: Above,1,000 square meters
No. of Production Lines Above 3 producce line,80 units machine
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range Reasonable; Average;