• Raw Materials for Refractory:High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SiC System 1
  • Raw Materials for Refractory:High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SiC System 2
  • Raw Materials for Refractory:High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SiC System 3
  • Raw Materials for Refractory:High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SiC System 4
Raw Materials for Refractory:High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SiC

Raw Materials for Refractory:High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SiC

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT or LC
Min Order Qty:
25 m.t.
Supply Capability:
3000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SIC

1.Structure of Silicon Carbide Description

Black Silicon Carbide is produced with high temperature in a electric resistant furnace from a mixture of quartz sand and petroleum coke.

Black silicon carbide is typically used for working on cast iron ,non-ferrous metals, stone, leather, rubber, and other materials which requires sharp cutting characteristics. The mineral is also used widely as a refractory material and metallurgical additive. 

2.Main Features of the Calcined Bauxite

Its hardness is between that of fused alumina and synthetic diamond and mechancial intensity of it is also greater than that of fused alumina. It is brittle and very sharp and  has a certain degree of electrical and heat conductivity.

3.Main usage of the Calcined Bauxite

1.Grinding non-ferrous materials, rock, stone, leather, rubber, finishing tough and hard materials

2.Bonded abrasive tools, lapping and polishing

3.Widely used as a metallurgical additive and refractory material

4.Refractory

4. Calcined Bauxite Images

 

High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SIC

High Quality Low Price Mineral Lump Grades of Black Silicon Carbide/SIC


5. Calcined Bauxite Specification

Grade

SiC

F.C

Fe2O3

SiC98.5

98.5

0.20

0.60

SiC98

98

0.30

0.80

SiC97

97

0.30

1.00

SiC95

95

0.40

1.00

SiC90

90

0.60

1.20

SiC70

70

3

/

SiC65

65

5

/

SiC60

60

10

/

SiC55

55

10

/

SiC50

50

10

/



6.FAQ of Calcined Bauxite

1). Q: Are you a factory or trading company?

A: We are a factory.

2). Q: Where is your factory located? How can I visit there?

A: Our factory is located in Ningxia, China. You are warmly welcomed to visit us!

3). Q: How can I get some samples?

A: Please contact me for samples


Q: Does anyone know what kind of light fireproof materials are there?
二, 1, Gypsum plaster board With the building plaster as main raw material, gypsum plaster board is a kind of processed plate made by a special board for protective with an addition of additives and fibers as board core. Gypsum plaster board is characterized by light weight, sound insulation, heat insulation, strong processing performance and simple construction method. 2, Gypsum block Gypsum block is a kind of lightweight building gypsum product which is mainly made of building gypsum, and by adding water, stirring, casting and drying. During the process, , the fiber reinforced materials or light aggregates are allowed in, and the foaming agent can also be added. It has many advantages, such as sound insulation and fire prevention, convenient construction and so on. It is a kind of new and healthy wall material which produces low carbon, enhances environmental protection, and caters to the the times. 3, Fly ash brick is a new type of wall material, and bulk density is one of the main technical indexes. The weight of bulk density can be controlled according to the need of construction and adjustment of technical formula. The dry bulk density of the fly ash brick is about 1540 to 1640 kg / m 3, slightly lighter than the clay brick (1601800 kg /m 3). The flexural and compressive strength of fly ash brick is mainly determined by the production process, the formula and the hydrothermal synthesis reaction mode as well as the need of construction. According to the standards of architectural material industry (JC239 - 2001) released by People's Republic of China, the average value of the flexural strength is 2.5 ~ 6.2Mpa, compressive strength is between 10 ~ 30Mpa. I hope this will be helpful to you
Q: how about the performance of aluminum silicate fire proof thermal insulation?
aluminum silicate fire proof thermal insulation board has a good performance. it is a artificial board that separates the wood and plant fiber by mechanical and chemical methods and mixed the adhesion agent and water-proofing?agent, molding by high temperature and high press. MDF(medium density fibre board) structure is more even than natural wood. it avoids rot, moth-eaten and other problems, while medium density fiber board has small expansion and contraction, which is easy to be processed. Since the surface of medium density fibre board is smooth, the board is easy to paste a variety of finishings, which makes furniture more beautiful. A variety of decorative wood-based panel is to embellish their homes.
Q: What type of firebrick does TZ-3 represent?
Height is 65mm, length is 230mm, and width is 114mm, that is the t-3 firebricks which meet the national standard.
Q: Which industry does refractory belong to?
It belongs to construction industry.
Q: What's the definition of fire endurance of the fire-resistant coating for steel structure?
1. Fire endurance. Conduct fire resistance test of any building component according to the standard time-temperature curve, and the time when it is subjected to the fire to the time when it loses support capability or fire insulation function or its integrality is destroyed is referred to fire endurance. 2. Steel has relatively low fire endurance which is usually 0.25h only, namely 15 minutes; 3. Of steel structure buildings, steel can be used as beams, pillars, etc. but its fire endurance is not enough (usually these components have higher requirement on fire endurance, and take pillar as an example, it is usually demanded that the fire endurance should be 2-3h), and under this condition, it needs to brush fire retardant coating so as to raise the fire endurance. As to the specific quantity or types of the fire retardant coating, it is decided upon the actual conditions. In short, the building material needs to meet the required fire endurance of the buildings.
Q: Is the linear change on reheating the same as heating permanent linear change of refractory material?
“+”represents expansion. the afterexpansion and aftercontraction after cooled to be at room temperature. The change may significantly damage the masonry of thermal kiln. There are regulations on the linear change on reheating of common refractory material in the national standard. Some physical chemical changes may continue. It is defined as the change from being heated to the specified temperature of refractory material sample. Heat preserving for a while till afte cooling to be at room temperature, then the residual will expand or contract in its length, heat preservation for a while, organization vitrification, the irreversible changes of its length refers to heating the firing refractory to be at high temperature, so as to make the volume of refractory materials expand or contract, due to the influence of uneven temperature or lack of time, otherwise it will cause the deformation of the refractory ball and make this indicator within standard even reach smaller value, so firing control must be strengthened in product production. But it is should not be too high. For refractory materials with same chemical composition, the linear change on reheating is produced in the heating process. Properly increasing sintering temperature and prolonging the holding time is an effective process measures, make its firing inadequate. When subjected to high temperature, it can reduce the thermal shock resistance. Minus sign "-" represents contraction. The permanent line rate refers to heating the fire refractory ball to the specified temperature. Linear change on reheating, also known as residual linear change, is an important indicator to assess the quality of refractory in the long time use. To control the permanent line rate within the standard or reach the minimum value.
Q: Who knows the new fireproof and thermal inuslation matertial?
New fire insulation material, having a foam material body, with the following characters: Outside of the foam material body bonds the aluminium foil composite glass fiber cloth, which is bonded by the aluminium foil and glass fiber cloth through fireproof glue. The utility model has the following advantages: Bonding the aluminum foil composite glass fiber cloth to the outer surface of the foam insulation material, will strengthen thermal insulation index, also will prevent the burning of the foamed material, thus ensuring the fireproofing safety of the foam insulation material.
Q: What's the fire resistance test method of doors and roller shutters?
Fire resistance test method of doors and roller shutters: This standard specifies the fire resistance test method for roller shutter doors under standard fire conditions. The method is used to test the fire resistance of the ventilating duct when bearing the external fire (A duct) and internal fire (B duct). Fire resistance test of vertical ducts may be conducted referring to this standard. 1.Test specimen1.1 The test specimen is obtained by cutting from any part of the qualified metal tube unless otherwise relevant standard or mutual agreement specifies the cutting position of the metal tube. 1.2 Length of the specimen: L≈2.5D+50mm (D: outer diameter of the metal tube). The cut surface of the specimen must be perpendicular to the axis of the metal , and the seamed edge of the cut should be round off. Test method GB243-82 of metal tube necking 2. Test procedures 2.1 In the test, punch or press the metal tube into the tapered conical seat (see Figure) with a hammer or press machine, and make it uniformly diminished to the regulated shrinkage X which is calculated according to the following formula: Test method GB243-822 for metallic pipe necking: The inner wall of the seat cover used in the test should be polished, and has certain hardness and is coated with lubricating oil. Its conicity is 1:10, 1:5 or others in accordance with relevant standard provisions. If there is no provision, then adopt the conicity of 1:10. This standard is not suitable for: a) The pipeline whose fire resistance depends on the fire resistance of the ceiling; b) The pipeline with access door, unless otherwise the access door is included into the pipeline and tested together; c) The pipeline with two or three sides; d) Fume exhaust pipes;
Q: who knows the fire endurance of fireproof coating?
fireproof coating of different thickness differs in its fire endurance. Let me intrduce you as follows: The amount of time of 0.5 hours refractory thickness 0.45mm 0.79kg / m21 hr 0.9 mm 1.5kg / m21.5 hour 1.4 mm 2.3kg / m22 hr 2.0 mm 3.3kg / m22.5 h 2.8 mm 4.6 kg / m2
Q: What's the A grade fireproofing material?
A grade fireproofing material: 1. fire-proof plate; 2. fireproof wooden door; 3. fireproof wooden window frame; 4. fire resisting shutter; 5. fireproof and mothproof wood; 6. fireproof glove compartment; 8. fire?retardant?coating; 9. fire-proof?sealing?material.