Rated voltage 10KV or lower Aerial Bounded Cable ABC
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Application
It is used to rated voltage U (Um) 10 (12 kV) overhead power lines, copper or aluminum conductor, XLPE or High-density PE insulated overhead cable.
Type & Specification
Voltage | 10 kV |
Type | JKYJ、JKTRYJ、JKLYJ、JKLHYJ、JKY、JKTRY、JKLY、JKLHY、JKLYJ/Q、JKLY/Q、JKLHYJ/Q、JKLHY/Q |
Size(mm2) | 1 Core:10~400 |
Standard | GB∕T 14049-2008 |
The maximum allowable operating temperature of cable conductor (with load-bearing structure): XLPE insulation 90℃;high-density PE insulation 75℃.
When short circuit (the maximum duration is no more than 5 seconds) cable maximum temperature should not exceed: XLPE 250℃;high-density PE insulation 150℃.
Cable laying temperature should not be less than -20℃.
Cable bending radius no less than the cylinder diameter for cable bending test.
Structure
Application
It is used to rated voltage U (Um) 10 (12 kV) overhead power lines, copper or aluminum conductor, XLPE or High-density PE insulated overhead cable.
Type & Specification
Voltage | 10 kV |
Type | JKYJ、JKTRYJ、JKLYJ、JKLHYJ、JKY、JKTRY、JKLY、JKLHY、JKLYJ/Q、JKLY/Q、JKLHYJ/Q、JKLHY/Q |
Size(mm2) | 1 Core:10~400 |
Standard | GB∕T 14049-2008 |
The maximum allowable operating temperature of cable conductor (with load-bearing structure): XLPE insulation 90℃;high-density PE insulation 75℃.
When short circuit (the maximum duration is no more than 5 seconds) cable maximum temperature should not exceed: XLPE 250℃;high-density PE insulation 150℃.
Cable laying temperature should not be less than -20℃.
Cable bending radius no less than the cylinder diameter for cable bending test.
Structure
- Q: i have a 12V battery and a y power cable. will each side get 12V?
- yes you will have 12V each side, why?..because of the Kirchhoff's Loop Rule.. delta V = 0 for any path in a circuit that starts and ends at the same point. google the Kirchhoff's Loop Rule for more detail
- Q: What is the difference between a photovoltaic cable and an ordinary cable? What is the structure of a photovoltaic cable?
- Cable bridge is used to support and protect a variety of cables, in power plants, substations, large industrial and mining enterprises, high-rise buildings are widely used. But are a one-time infrastructure in place, usually no longer replace and add.
- Q: hi,i was wondering...can battery powered tv have cable? or do the battery powered tv not need cable? my niece likes spongebob so if she does come over she can watch it....but i just want to know before i buy it...thanks...P.S:so do they already have all the cable shows?or they dont?and if they dont do you have to put cable....and if they cant....then i shouldn't buy it?
- How can you have cable without a cable connection? If they come with an antenna, you get off-the-air programs. To get cable, the TV needs to have a cable tuner and you need to have a cable feed.
- Q: I don't know what kin d of power cord i would need in order to make it work. I thought all monitors needed the same power cable, but im not sure.
- Most equipment uses the IEC plug on the monitor end and the particular power plug your country uses for the other end. Your monitor handles all the international voltages, so you can be sure it will work anywhere.
- Q: Hi,I have an LED monitor ordered and I wanted to know if it has a power cable. The monitor I ordered is a Samsung S23C350HS 23 Inch Screen LED-Lit Monitor. Thank you,
- No question about it a monitor whatever the make will have or need a power cable there have not been any monitors made that can recieve enough power from any other lead connected to the computer
- Q: Cable model YJV4 * 25 + 1 * 16 what does it mean ah
- " Why should the closed wall or protective wall closed on the second side of the closed junction box? This need to understand if you do not add this closed junction box, what kind of harm Civil air defense project in the closed wall is divided into the clean area and the area of ??the infected area, and the wire tube in the thread after the inside is a cavity, directly through the wall to communicate with the cleaning area and exposed areas, so wartime works outside the dyeing The poisonous air can penetrate into the clean area through the cavity inside the wire tube, which is harmful to the personnel inside the project And the installation of a sealed junction box, you can thread in the line after the box filled with sealing material to block the tube cavity connectivity This is why the electrical safety pipe in the air defense project must pass the closed wall or protect the closed wall when the two sides must be closed in the closed junction box reasons
- Q: is there a cable for UPS where i can connect this kind of adapter?
- You local should have the cable you need...
- Q: Trying to troubleshoot my computer I have been unplugging and replugging wires. After a while of looking around I have found that the ATX power connector is missing a part of the pin. Now my computer is unable to boot. Is there a way to fix it. Or am I stuck going to get to a new computer.
- Im confused, which cable is this? If this is a home-built PC RMA your power supply but if it's a HP/Dell/Whatever then call them for support and/or warranty info.
- Q: Electrical equipment installation project "power cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area, such as 3 × 25mm2 refers to 25mm. 75mm2 or cable cross-sectional area of 490mm2? More
- Said cross-linked polyethylene insulation, double steel armor, PVC outer jacket. Voltage level 0.6 to 1 kV, 5 core, cross section 10 square millimeters. About four centimeters in diameter.
- Q: Honda Accord Executive on a 56' reg car.Fitting help much appreciated.
- Probably not easy but if ya find the hole in the firewall underneath ya dash somewhere than just poke it through there and run it underneath ya carpet. After that u'll just be able to find ya way into the boot with no problem. I like running the power cable down the centre of the car but that can sometimes be more of a hassle than its worth, so along the side of ur seat is cool.
Send your message to us
Rated voltage 10KV or lower Aerial Bounded Cable ABC
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 10000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords