PVC(XLPE)InsulatedFire-Resistant Power Cable 0.6/1kV
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
产品标准
本产品按GB12706《额定电压35kV及以下铜芯、铝芯塑料绝缘电力电缆》和GB12666《电线电缆燃烧实验方法》标准生产,同时还可根据用户需要按国际电工委员会推荐的IEC标准、英国BS标准、德国DIN标准、美国ICEA标准及日本JIS标准生产。
The product is manufactured according to the standard of GB12706 and GB12666 or IEC,BS,DIN,ICEA,and JIS upon request.
适用范围
本产品适用于工频额定电压0.6/1kV及以下配电线路或工业装置中有耐火要求的固定敷设场所使用。
The product is suitable for use in power distribution lines or fixed installations with rated power-frequency voltage up to and including 0.6/1kV.
使用特性
·工频额定电压U0/U:0.6/1kV。
Rated power-frequency voltage U0/U:0.6/1kV.
·电缆导体的最高允许长期工作温度(PVC/XLPE):70℃/90℃.
Max.permissible continuous operating temperature of conductor (PVC/XLPE): 70℃/90℃
·短路时(最长持续时间不超过5s)电缆导体最高允许温度
PVC:导体截面≤300mm2-160℃
导体截面>300mm2-140℃
XLPE:250℃
Max.short-circuit temperature of the conductor shall not exceed(5s maxiumduration):
PVC:cross-section of conductor≤300mm2-160℃
cross-section of conductor>300mm2-140℃
XLPE:250℃
·电缆敷设时环境温度应不低于0℃
The ambient temperature under installation should not below 0℃
·电缆的弯曲半径:多芯电缆不小于电缆外径15倍,单芯电缆不小于电缆外径20倍。
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of multicore-cable should not less than 15 times of the cable diameter.
We are experienced in cooperating with global customers who are leaders in their industries, which has helped us to accumulate valuable expertise in many fields。
- Q: I got a XFX radeon 5750 graphics card and after a lot of trouble I realized that I hadn't plugged in the 6 pin PCIe power cable, but I don't see any slots on my power supply, does anyone know how to fix this problem? I really don't wanna buy another power supply :(
- It okorder /
- Q: ill exlplain more the battery is connected to one end of the fuse then i want to run 2 power cables out of the other end to both of the amps will tis work or will i just loose power the fuse is 60A if that helps. 60A is massive why a fuse that big is needed i dont no
- relatively there is alot incorrect alongside with your techniques. First. do not placed subs and substantial audio equipment in parallel with one yet another on an identical amp. One set is low freq and the different is higer. you are able to desire to seperate them. Get yet another amp for the 2nd set of audio equipment. additionally, switching the audio equipment out and in could chage the load the amp sees. solid thank you to screw some thing up with a change turning them on and rancid. purely get 2 amps and function one for substantial and one for subs. additionally, make helpful the turn on twine is on change voltage. you have it setup to consistently be on and which will run your battery ineffective. additionally, do not twine speaker on your radio/cd participant and additionally to the amp. you will fry the setup quickly!
- Q: Interested to learn more about selection of Power Cable for Diesel Generating Sets. I have checked out a few websites, but they are all too complicated and ask too many questions. Would like to know if there is a thumb rule for this?
- Power cable size will depend on the output current rating of the genset. The conductor size shall be rated for carrying the maximum genset current contnuously and shall be rated for the voltage of the genset.
- Q: I know there is problem in the CPU, please suggest what is the problem and how much it is going to cost me?
- The power cable goes in the power supply, not the processor (CPU: Central Processing Unit) That's your problem
- Q: So I have this monitor that only has ONE port on it, which is a USB cable slot. Typically you would connect it to a laptop, and the USB cord also supplies it power at the same time display connection.
- I'd really like to see what monitor you're talking about, and make sure that it has nothing except a USB port. Then I'll figure out the RCA power question.
- Q: i need a power cable for a viewsonis VE170mb monitor
- I believe viewsonic uses a European cable or regular computer power cable at least most of the ones I have repaired.
- Q: I bought a new amp and sub to replace my old ones. I disconnected the battery, unplugged the old amp and plugged the new one in and when I reconnected my battery the power cable began to smoke at all the exposed ends and got very hot. What causes this? Is it because the new amp requires more current than the old one and that is causing it to get very hot? And what is the solution to my problem?Thanks
- you are creating a short circuit with the battery if this is happening while the amp is not on. disconnect all wires and make sure your positive lead goes to only positive terminal /amp input. then do the same for the ground. if you dont have a fuse protecting the wire it will get so hot it will melt the insulation and start a fire. if this is happening only when the amp is on and your system is pulling a large current through it (music real loud) then you need to upgrade your wires asap. make sure you have a fuse protecting the power wire close to the battery and a fuse whenever you downgrade in size of wire. a $1 fuse with the correct rating for the wire its protecting will safe your *** if you short circuit.
- Q: I just bought it!
- Why would the power cable make noise? It's just a cable.
- Q: I have lost the Power cable and couldn't find it anywhere but i have tried using my Printer's cable (HP) and it worked but i am wondering if there is any risk from using it? could it affect the ps4 in any way?
- Nope it won't affect your PS4. I do suggest you get a new Printer Cable too.
- Q: I recently bought a 750watt power inverter and there are two small cables to connect to it that look like small jumper cables. Can i connect my regular (longer/bigger) jumper cables to the car battery and connect the other end to the inverter cables??Ive been told that this will blow the inverter, and i've been told otherwise. Please let me know if you've had any experience doing this.Thanks,
- Mini Jumper Cables
Send your message to us
PVC(XLPE)InsulatedFire-Resistant Power Cable 0.6/1kV