Online UPS 20KVA
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Online UPS 10-20KVA
The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.
Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.
Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.
Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.
Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.
Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1
minute in load of 125-150% . It also has the output short circuit protection capability.
MODEL | XPC 3110L | XPC 3115L | XPC 3120L |
Rated Power | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW |
INPUT | |||
Phase | 3W+N+G | ||
Input Voltage | (207-475)VAC | ||
Input Frequency | (46-54)Hz | ||
Input PF | >0.95 | ||
Bypass voltage | (302-437)VAC | ||
OUTPUT | |||
Output Voltage | 220VAC±1% | ||
Output Power Factor | 0.8 | ||
Output Frequency | Normal mode:same with utility power Battery mode:49.9~50.1Hz | ||
THD | THD<3% (linear load);THD<5% (non-linear load) | ||
Transfer Time | Normal to battery mode: 0ms Bypass mode to normal : 0ms | ||
Overload Capability | load≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing 105±5%<load≤135±5%:60s 135%≤load≤150±5%:30s >150%:0.1s | ||
BATTERY | |||
Voltage | 192Vdc | ||
Charging voltage | 220Vdc | ||
Overvoltage | 230Vdc | ||
Charging Current | 2A/4A(L type) | ||
SYSTEM | |||
Efficiency | >92% | ||
Communication | LCD display+RS-232 + Intelligent slot | ||
Restart Function | After turning off due to cut off voltage of battery, UPS will restart when voltage is in (302~437Vac) and frequency is in (47~53Hz). | ||
Noise (1m front) | <45dBA | <50dBA | |
Operation Temperature | 0°C to 40°C | ||
Humidity | 0~95% non-condensing | ||
Storage Temperature | -40°C to 50°C | ||
Altitude | 1000m | ||
Dimension(WXDXH) | 248×500×616 | ||
Weight(kg) | 27 | 35 | 35 |
Specification is subject to change without prior notice. |
- Q: What is the difference between EPS and UPS functions?
- UPS is the abbreviation of "UninterruptiblePowerSupply", which is often referred to as "UPS" uninterruptible power supply. The common UPS power supply on the market mainly has two types: Online (OnLine) and backup (OffLine).EPS emergency power supply system is the abbreviation of Emergency Power Supply. It is an emergency power supply that meets the special requirements of fire protection industry.
- Q: Sometimes the voltage is as low as 130, and the computer cat is fully restartedDid you buy a regulator or reboot?
- UPS (Uninterruptible, Power, System), that is, uninterruptible power supply, is a kind of energy storage device, inverter as the main component of constant voltage constant frequency uninterruptible power supply. Used primarily to provide uninterrupted power supply to a single computer, computer network system, or other power electronic equipment. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately machine battery power through the inverter conversion method continue to supply 220V AC power to the load, the load to maintain normal working load and protection of software and hardware is not damaged. UPS devices usually provide protection against too large voltages and too low voltages.
- Q: What's the difference between UPS and UP5?
- The meanings of the representatives are differentUPS is an uninterruptible power supply.UP5 is a micro DC power supply, also called distributed DC power supply, or embedded DC power supply and micro DC power supply".
- Q: What about the UPS power supply, okay?
- When the power input is normal, UPS electric voltage supplied to the load, the UPS power supply is an AC power regulator, it is also the built-in battery; when the power interruption, UPS will immediately built-in battery power supply, load to 220V AC negative by the method the inverse transformation of the load, maintain normal work and protect the load of software and hardware is not damaged.
- Q: What server UPS power line?
- UPS model and brand are more, personal advice you can follow the following ways to start. 1 know the power of all your servers or other network devices. 2, you need to use all the power protection equipment added up to 3, according to the calculated total power of all your equipment total power calculate capacity of UPS 4, according to your needs to select the UPS brand and the corresponding models (e.g. your UPS or rack installation, tower installation, do a redundant backup machine and so on) 5 according to your UPS, make and model, calculate the backup time you need battery size and capacity (by the way you can also choose the battery brand). 6, according to the calculated results above all to find the price for brand suppliers to discuss the opposite (you may according to the above requirements of many brands can meet your requirements, you can find the corresponding brand consulting agents, according to the highest price for agents). Hope to appeal, reply to help Louzhu, thank you! If you need detailed configuration solutions, you can send your request list to my mailbox , and I can follow you as a reference.
- Q: My family has UPS, I found it on the Internet, but I don't know much whether my computer is working, suddenly there is no electricity or the voltage is too low, the computer will not restart. Will you work for a short time? But why isn't my family UPS like that? A low voltage will ring, and then my computer will be the same restart, but in the absence of power, with his computer to open a while, is my understandingWhat do you mean by the third?Also, when my home voltage is lowest, 160 of the voltage regulators are not workingPlease answer my person and tell me which one is right. I want to knowThank you and IThat is to say, UPS has the function of stabilizing, and?????
- UPS: also called uninterruptible power supply, divided into online and off-line (i.e. not regulated and with a voltage stabilizing power or voltage), is out of the 170-260V battery powered, battery power supply standard continued for about 10 minutes, long time to power supply to external batteries.Your current situation may be that the battery for UPS is running out160V voltage is too low, the solution: with CWY parameter regulator or on-line UPS., you already have UPS, should use parameter regulator +UPS.
- Q: UPS model problem
- What type of UPS does a typical computer use?Answer: general computer can use backup type UPS, different manufacturer name way is different, general price is in 500 the following are.
- Q: How does PLC use UPS?
- PLC is quite like a microcomputer. You can use UPS directly if you can use it on the city bus and the backup ups with your own socket! About 200--300w or so, configure a 500VA on the OK, can delay a 10--20min!
- Q: A few days ago, the thunder, my computer power and network card hack, and power amplifier speaker received voltage regulator, nothing.I wonder if UPS has any voltage stabilizing function? In thunder, voltage, current suddenly too big, will automatic voltage regulation?
- Now the general UPS have steady voltageSantak's TG series is not available. There are other inexpensive machines, tooGeneral prices are, 175V to 275VWell, it's 145V to 300V
- Q: There are several ups
- Reserve UPS power supply mode is that the city power input UPS power, divided into two running, all the way for equipment direct power supply, the other way through the UPS power supply will be converted to DC power supply for battery charging
Send your message to us
Online UPS 20KVA
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches