Online UPS 15KVA
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Online UPS 10-20KVA
The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.
Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.
Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.
Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.
Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.
High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.
Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1
minute in load of 125-150% . It also has the output short circuit protection capability.
MODEL | XPC 3110L | XPC 3115L | XPC 3120L |
Rated Power | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW |
INPUT | |||
Phase | 3W+N+G | ||
Input Voltage | (207-475)VAC | ||
Input Frequency | (46-54)Hz | ||
Input PF | >0.95 | ||
Bypass voltage | (302-437)VAC | ||
OUTPUT | |||
Output Voltage | 220VAC±1% | ||
Output Power Factor | 0.8 | ||
Output Frequency | Normal mode:same with utility power Battery mode:49.9~50.1Hz | ||
THD | THD<3% (linear load);THD<5% (non-linear load) | ||
Transfer Time | Normal to battery mode: 0ms Bypass mode to normal : 0ms | ||
Overload Capability | load≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing 105±5%<load≤135±5%:60s 135%≤load≤150±5%:30s >150%:0.1s | ||
BATTERY | |||
Voltage | 192Vdc | ||
Charging voltage | 220Vdc | ||
Overvoltage | 230Vdc | ||
Charging Current | 2A/4A(L type) | ||
SYSTEM | |||
Efficiency | >92% | ||
Communication | LCD display+RS-232 + Intelligent slot | ||
Restart Function | After turning off due to cut off voltage of battery, UPS will restart when voltage is in (302~437Vac) and frequency is in (47~53Hz). | ||
Noise (1m front) | <45dBA | <50dBA | |
Operation Temperature | 0°C to 40°C | ||
Humidity | 0~95% non-condensing | ||
Storage Temperature | -40°C to 50°C | ||
Altitude | 1000m | ||
Dimension(WXDXH) | 248×500×616 | ||
Weight(kg) | 27 | 35 | 35 |
Specification is subject to change without prior notice. |
- Q: How long is the battery life of the UPS power supply?
- Charging voltage:Because the UPS battery belongs to the standby mode, the city power is in the normal state of charge and will only be discharged when the power fails. To prolong the life of battery charger, UPS generally uses the constant pressure limiting control, after the battery is turned into floating state, each section of the floating voltage set to about 13.6V. If the charge voltage is too high, the battery will be charged, otherwise the battery will not be charged enough.
- Q: What is the difference between EPS and UPS functions?
- Online UPS when power supply is normal, the rectifier provides DC voltage to the inverter by electricity from the inverter to provide AC power load, power anomaly in the city when the inverter powered by battery, the inverter always in working condition, ensure uninterrupted output. The utility model is characterized in that the utility model has the advantages of extremely wide input voltage range, no switching time, stable output voltage and high precision. The utility model is especially suitable for occasions with high power supply requirements, but the cost is higher. At present, UPS with power greater than 3KVA is almost all online UPS.
- Q: Sometimes the voltage is as low as 130, and the computer cat is fully restartedDid you buy a regulator or reboot?
- UPS (Uninterruptible, Power, System), that is, uninterruptible power supply, is a kind of energy storage device, inverter as the main component of constant voltage constant frequency uninterruptible power supply. Used primarily to provide uninterrupted power supply to a single computer, computer network system, or other power electronic equipment. When the power input is normal, UPS electric voltage supplied to the load, the UPS is an AC power regulator, it is also the built-in battery; when the power interruption (outage), UPS will immediately machine battery power through the inverter conversion method continue to supply 220V AC power to the load, the load to maintain normal working load and protection of software and hardware is not damaged. UPS devices usually provide protection against too large voltages and too low voltages.
- Q: UPS power how to distinguish between the marking machine and the long machine, what are the criteria, or industry rules?
- UPS power is generally divided into long machine and machine parts, machine must be external battery (with a battery cabinet), standard machine is inside the machine with the battery, the easiest way is: you don't have to take electricity directly with UPS power on, if you can boot is marking machine is not a machine, long open.
- Q: The principle or function of four major components of UPS power supply equipment are briefly described
- Through reasonable control, the controller makes the UPS power supply the computer with stable and reliable electric energy according to the design requirements. Controllers play an important role in UPS.
- Q: How old is the 12 volt car inverter in use?
- UPS has the power inverter in working state, the external alternating current into direct current through the circuit, then through high quality inverter to convert DC to high quality sine wave AC output to the computer. The main function of the on-line UPS in the power supply condition is to regulate voltage and prevent radio wave interference. In the power failure, the standby DC power supply (battery) is used to supply the inverter. Because the inverter is working all the time, there is no switching time problem. It is suitable for occasions where the power supply is strictly required. A major advantage of online UPS power supply is different from the backup power supply for a long, usually for a few hours, also have to ten hours, its main function is to allow you to be working as usual, in case of power failure obviously, because of its special function, the price is clearly a big section. This on-line UPS is more suitable for computers, transportation, banking, securities, communications, medical, industrial control and other industries, because computers in these areas generally do not allow blackouts.
- Q: What are the specific use notes?
- UPS is the abbreviation of uninterruptible power system, which is an important external equipment to provide continuous, stable and uninterrupted power supply.
- Q: What does the UPS parameter of the 1500KV power mean?
- Brother, you're wrong about this description. There's no 1500KV,It should be 1500VA, and Chinese is called volt ampere,VA is also a unit of power, similar to W, but there are some differences......
- Q: Excuse me: how long is the service life of the UPS power supply?
- The host can twenty years can, but some capacitance some accessories to click, lead-acid battery design life with the environment has great relationship. Then the general battery is 7 to 8 years, but the general use of 3 to 4 years will be changed, then the general gel battery can be used 6 or 7 years life, a great relationship with your maintenance. Specific, you can go to www.gdbaykee this website to check
- Q: Don't be too professional, just teach me, thank you!
- The three UPS power supply plug inserted into the body with the power plug, open the UPS power switch, UPS power supply to work, then the power line computer host and display the plug into the socket body behind the UPS power supply, one by one to boot.
Send your message to us
Online UPS 15KVA
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords