Product Description:

Online UPS 10-20KVA

The XPC series 10-20K series is applicable to small and medium-sized data centers, network management center, computer rooms for enterprises, or able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage pulse, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation. XPC series 10-20K series UPS provide customers safe and sound power supply.

Excllent performance in industrial environment protection
Just with the standard product, IP21 protection level (protecting the machine from the intrusion of solid material
with the diameter larger than 12mm or the water drops) is achieved. If a higher protection level is required, the
optional dust-proof accessories can help to increase the protection level in industrial environment and safeguard
the ups security when operation in bad environment.


Ientelligent management of battery charging and discharging
The advanced battery intelligent charging technology enables the UPS's charger to rectify the charging parameter,
and provide the optimum charging modes in the different environment, types and amounts of cells, and the using
condition of the battery. The scientific charging mode extends the battery's lifetime. The optional addition to
charging units shortens battery charging time.


Front board operation and maintenance
The smart module design and front board design make the users operation more conveniently and easily.


Remote monitoring
Communication interfaces like RS232/RS485, Intelligent Slot of JingFuYuan Company are available for the realization
of remote management and monitoring.


High-efficient DSP chip
The digital Ti DSP controlling chip provides precise data processing capability with excellent performance in output
and reliability.


Outstanding electric property
The efficiency of the machines is as high as 93% and reaches over 98% in the ECO mode, which can help reduce the
power loss of UPS. Because of the technology of IGBT FM intelligent rectifier and inverter is used , the input power
factor is as high as 0.99,and the input current harmonic wave is as low as 3%,which makes the output voltage electric
property more extraordinary.
Powerful overload capacity: the ups can work normally up to 10 mins under the condition of 110-125% load and 1

minute in load of 125-150% . It also has the output short circuit protection capability.


MODELXPC 3110LXPC 3115LXPC 3120L
Rated Power10KVA/8KW15KVA/12KW20KVA/16KW
INPUT
Phase3W+N+G
Input Voltage(207-475)VAC
Input Frequency(46-54)Hz
Input PF>0.95
Bypass voltage(302-437)VAC
OUTPUT
Output Voltage220VAC±1%
Output Power Factor0.8
Output FrequencyNormal mode:same with utility power
Battery mode:49.9~50.1Hz
THDTHD<3% (linear load);THD<5% (non-linear load)
Transfer TimeNormal to battery mode: 0ms
Bypass mode to normal : 0ms
Overload Capabilityload≤105±5%:normally run;normal mode,turn to normal mode after overload disappearing
105±5%<load≤135±5%:60s
135%≤load≤150±5%:30s >150%:0.1s
BATTERY
Voltage192Vdc
Charging voltage220Vdc
Overvoltage230Vdc
Charging Current2A/4A(L type)
SYSTEM
Efficiency>92%
CommunicationLCD display+RS-232 + Intelligent slot
Restart FunctionAfter turning off due to cut off voltage of battery, UPS will restart
when voltage is in (302~437Vac) and frequency is in (47~53Hz).
Noise (1m front)<45dBA<50dBA
Operation Temperature0°C to 40°C
Humidity0~95% non-condensing
Storage Temperature-40°C to 50°C
Altitude1000m
Dimension(WXDXH)248×500×616
Weight(kg)273535
Specification is subject to change without prior notice.


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:What does "EPS" and "UPS" mean? What are their respective areas of use?
Their common place is that there are bypass, inverter, battery charging circuit, which can provide battery inverter emergency power supply when the city electricity is abnormal. The difference is that UPS is very precise, rectifier and inverter double shift work, ensure the output interruption time is less than 10 milliseconds when power (typically 0 milliseconds interrupted, because the inverter has been at work); EPS precision is low, the outage time off time is generally greater than 10 milliseconds, between 10-50ms, if the server, this time breaks more than 20ms will restart.
Q:What is the name of the device that provides the server with power?
You should say is UPS (uninterruptible power supply system), installed between the power and the server, in the case of external power failure, you can automatically switch to the UPS, the internal battery powered, and not to suddenly lose power, resulting in data loss
Q:How to fit a battery pack for a UPS power supply
The maximum discharge current calculation of battery value: I =Pcos (*E *N / Phi ETA critical)Note: nominal power output of P to UPS powerThe output power factor cos, Phi UPS power (power frequency machine is generally 0.8)Efficiency, UPS inverter, usually 0.88~0.94 (the actual calculation can take 0.9)The critical discharge voltage of E critical storage battery (12V battery is about 10.5V, 2V battery is about 1.67V)N = the quantity of each batteryAccording to the backup time of the selected battery, find the discharge rate value C of the required battery, and then according to the:
Q:A server that maintains power close to 320W and runs over 8 hours of UPS power
In fact, a brother said the truth you load the ability to charge low power UPS did not reach the example of APC SU series machine 48V good for 8 hours with UPS configuration results 1 hours are not up to the person to suggest that you should be able to match the actual 3K suggest you brand Santak because Santak is 8 a group should be charged
Q:What's the SCR rectifier for UPS?
UPS and DC power supply enterprises is an important power supply protecting device, the traditional maintenance management includes: daily inspection appearance, regular replacement of batteries, filter capacitor, fan wearing parts, overhaul battery activation; the modification or replacement of equipment by using advanced tools, test battery performance. This kind of management means high cost of investment and heavy workload of maintenance personnel. It is difficult to grasp the equipment running state and key data in real time, and the accident prevention ability of equipment is low. The implementation of online maintenance management can avoid the shortcomings of the traditional way, and get good results.
Q:Is the emergency output voltage of UPS DC or AC?
UPS output is AC, after the city power cut off, the internal inverter part will convert DC to AC, inverter output, and what do not understand, I have contact information in the data. Hangzhou Bo Hong Electronics Co., Ltd.
Q:What is the UPS power supply?
The function and function of UPS, UPS is the abbreviation of Uninterruptible (PowerSystem), which is accompanied by the birth of computer. It is one of the common peripherals of computer. In fact, the UPS is a constant voltage constant current source with an energy storage device and an inverter as its main component. At the beginning of its development, UPS was considered as an alternate power supply
Q:What is UPS/EPS?
UPS (Uninterruptible, Power, System), that is, uninterruptible power supply, is a kind of energy storage device, inverter as the main component of constant voltage constant frequency uninterruptible power supply. Used primarily to provide uninterrupted power supply to a single computer, computer network system, or other power electronic equipment.
Q:Why does the banking system need UPS power?
The utility model is mainly used for providing stable and uninterrupted power supply for a single computer, a computer network system or other power electronic equipment, such as an electromagnetic valve, a pressure transmitter, etc..
Q:Can UPS power turn DC48V into AC220?
The UPS power supply has the function of battery starting. It can be supplied by the battery and provide stable AC power output when the UPS power supply is not powered by the city. It provides a convenient and flexible program for customers. The advanced technology of the company balance UPS power supply using the most advanced technology with balance, stability, good stability, can still work normally even in shortage, especially suitable for many power environment is bad place to work.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range