Nonwoven Geosynthetics

Ref Price:
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
1*20FCL m.t.
Supply Capability:
100 Million M2 Per Year m.t./month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

 

 

 Nonwoven Geosynthetics

 

 

Introduction of Nonwoven Geosynthetics:

 

Good flexibility, permeability, filtration, separation and easy for construction.

 

 

Application of Nonwoven Geosynthetics:

 

Geotextile has excellent permeability, acquired, durability, which can be widely used in railway, highway, movement hall, Dams, hydraulic structures, hence hole, coastal shoal, reclamation, environmental protection and other projects. The main products are Synthetic staple fibers needle punched non woven geotextiles and slit and spilt film yarn woven geotextiles.

 

 

 

 Nonwoven Geosynthetics

 

 

Specifications:

 

Technical specification of long fiber spunbond Nonwoven geotextile

 

Density

Thickness

Breaking Strength

Elongation of Fracture

CBR Bursting Strength

Vertical Penetration Parameter

Equivalent Aperture

g/m2

mm

KN/m

%

KN

cm/s

O95mm

65

1.2

2.8

40 ~ 80

0.7

K x (10-1 ~ 10-3)

 

(K = 1.0 ~ 9.9)

0.07 ~ 0.2

75

1.4

3.3

0.8

100

1.6

5.0

0.95

150

1.52

7.5

1.5

160

2.0

8.5

1.60

200

2.4

11

2.10

250

2.8

14

2.60

300

3.4

16

3.20

400

4.0

21

4.0

500

4.5

25

4.8

 

 

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Maintenance time of the cushion on the roof of the building
Concrete watering maintenance time: the use of Portland cement, ordinary Portland cement or slag Portland cement mixed with concrete, not less than 7d;
Q:Basement cushion waterproof
First, the basement moisture treatment structure is usually: first in the basement wall outer surface wiping 20mm thick 1: 2 waterproof mortar, basement walls should be used cement mortar masonry, gray seam must be full; and in the basement floor and the first Floor floor is divided into two walls of the level of moisture-proof layer. The outer wall of the basement wall should be tampered with the soil with poor permeability.
Q:How to build a fine stone concrete cushion?
The cushion is primarily responsible for the load coming from the surface and passes the load evenly to the structural or base.
Q:Can the cushion on the prefabricated board floor be dug?
Prefabricated board floor layer of cement layer is not called the cushion, should be called leveling layer, this layer can be removed, but be careful not to damage the prefabricated plate.
Q:What is the waterproof layer and the waterproof cushion in the tile roof?
Waterproof layer: set in the tile or metal sheet below, from the waterproof, moisture-proof structure of the layer. The waterproof cushion plays an important role in the tile surface, because the "tile" itself can not be counted as a waterproof material, only tile and waterproof cushion combination to form a waterproof fortification.
Q:Foam concrete for the roof cushion generally do much bulk ah
in recent years, the density of 160kg / m3 ultra-light foam concrete is also used in construction projects.
Q:Large area ground concrete cushion seam Why is the separation of joints generally concrete
hird, the relevant parts Different types of rigid waterproof layer separation spacing in addition to meet the calculation needs, but also in the following parts set sub-grid joints. 1. The deformation of the roof structure sensitive parts; 2. Roof and roof drainage direction changes; 3. The junction of the waterproofing layer and the protruding roof structure; 4. Under normal circumstances, each bay load-bearing walls should be set sub-grid seam. 5. Between the waterproof layer and the load-bearing or non-load-bearing parapet or gable should be set sub-grid joints, and in the node structure for proper treatment.
Q:The cushion is usually in the housing which parts
There was no other place in the house below
Q:What is the difference between leveling and cushion?
Cushion is generally used in the ground floor of the building, leveling layer is generally used in the floor or roof. According to the above analysis, I believe that we use the quota, where the floor, roof construction, it should be used to find the level of the fixed sub-head, because there is no so-called concept of the cushion, leveling layer thickness is not what Specific provisions can also be used at the same time different layers of leveling, but must be carried out in accordance with the design requirements, so as not to exceed the load;
Q:Is the raft cushion waterproofing full of the cushion?
As for the bottom of the bar thickness of the protective layer is generally 4cm, but if the basic floor of the concrete label is relatively high, the protective layer can be appropriately reduced.
We are specialized in the production and marketing of non-woven fabric.

1. Manufacturer Overview

Location Hebei, China
Year Established 2004
Annual Output Value Above US$ 100 Million
Main Markets Europe; East Asia; America
Company Certifications ISO 9001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Qindao; Tianjin
Export Percentage 50% - 100%
No.of Employees in Trade Department 6-10 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: 6 million square meters
No. of Production Lines Above 10
Contract Manufacturing OEM Service Offered; Design Service Offered
Product Price Range