Medium-voltage XLPE insulated power cable
- Loading Port:
- China Main Port
- Payment Terms:
- TT OR LC
- Min Order Qty:
- -
- Supply Capability:
- -
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Specifications
110-220kv XLPE insulated power cable
1.XLPE CABLE Has passed CE,ISO,CCC,certificate
2.sell well in Europe, America, Asia
XLPE Insulated Power Cable
1.Basic Information.
Voltage : Low and Medium Voltage Cable
Conductor Material : copper
Insulation Material: XLPE
Sheath : PVC or PE
Appliation : Underground
Certificate : CE UL SGS ISO
Export Markets : Global
2.High voltage cable 64/110KV
Applying to GIS substations, hydropower stations, etc. 64/110KV .
Rated voltage 64/110KV XLPE copper core and PE insulated wrinkled aluminum wrapper waterproof layer PE(or PVC) sheathed power cable.
1. The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PVC sheathed power cable.
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage | Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. |
2.The cross-linkage PE insulated and wrinkled aluminum wrapper waterproof PE sheathed power cable.
Type | YJLW02, YJLLW02 |
Specification | 240mm2~3000mm2 |
Voltage | 110~220KV |
Usage |
Suitable for the places with a higher underground water level and to be used underground, in the tunnels or pipes. Such cables bear a bigger pulling force and pressure. |
Specific property for usage of 110KV~220KV XLPE high-voltage cable:
1. Cable’s conductor highest working temperature is allowed up to 90°C, and overload when meet an emergency is 130°C , When short circuit (in ≤5 seconds) the highest temperature is 250°C
2. When installing or laying cable, the ambient temperature should be less than -20°C, and have to give a preheat to cable.
3. The minimum bending diameter:
Cable type Bending diameter | Metal sheathed |
After laying | 30D0 |
During laying | 40D0 |
Note: In form, D0 is a real test value to cable’s outer diameter.
4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) T=K×core NO. ×section (kg), in formula, the coefficient K value should be: the copper core get 7, the aluminum core get 4.
5. Allowed biggest lateral-press P, when cable is being bent
The single core cable is required P≤500kg/m.
P=T/R (T is indicated axial traction force; R is indicated radius of bent-wheel), Knowing from above formula, as the traction force is made up by length and weight of cable. So it lets P to applying requirement as above. Then the diameter of bent-wheel should be widened.
6. Cable laying is not being restricted by drop.
3.Specification
Type | Designation | Application |
YJV | Copper conductor , XLPE insulated and PVC sheathed Electrical cable | For laying indoors, in tunnels or cable trench, unable to bear external mechanical forces. |
YJLV | Aluminum conductor , XLPE insulated and PVC sheathed Electrical cable | |
YJY | Copper conductor , XLPE insulated and PE sheathed Electrical cable | |
YJLY | Aluminum conductor , XLPE insulated and PE sheathed Electrical cable |
YJV22 | Copper conductor , XLPE insulated, steel tape armored and PVC sheathed Electrical cable | Indoors, tunnels, cable canal, vertically burying and easy to corrode places, can bear mechanical pressure. |
YJLV22 | Aluminum conductor , XLPE insulated, steel tape armored and PVC sheathed Electrical cable | |
YJV23 | Copper conductor , XLPE insulated, steel tape armored and PE sheathed Electrical cable | |
YJLV23 | Aluminum conductor , XLPE insulated, steel tape armored and PE sheathed Electrical cable | |
YJV32 | Copper conductor , XLPE insulated, steel wire armored and PVC sheathed Electrical cable | Vertically laying, can bear mechanical pulling force, but not pressure. |
YJLV32 | Aluminum conductor , XLPE insulated, steel wire armored and PVC sheathed Electrical cable | |
YJV33 | Copper conductor , XLPE insulated, steel wire armored and PE sheathed Electrical cable | |
YJLV33 | Aluminum conductor , XLPE insulated, steel wire armored and PE sheathed Electrical cable |
- Q: What is the difference between a photovoltaic cable and an ordinary cable? What is the structure of a photovoltaic cable?
- . soil buried pipe, including weak and fire, should be thick-walled galvanized steel pipe, that is, SC series of steel pipe, the best size is not less than SC. weak professional, decorative professional now basically use thin-walled galvanized steel pipe, that is JDG series steel pipe
- Q: I'm trying to run a cable and power outlet into a closet for a media space but im not sure how to add the outlets in there. The area where the closet is, is on a wall that has no outlets and behind the closet is a bathroom which has no outlets on that side of the wall either so theres nothing to tap into. please help.thank you.
- This is so situation and construction specific that it can't be answered. Anyone answering this would have to be there in order to tell you what the solution is. Tell ya what, give us full mechanical, structural, and electrical blueprints for your house and I'll tell you what to do. LOL. I'm sorry that your question is impossible to answer. I guess the real answer is to find someone handier than yourself.
- Q: eSata means you connect the drive from outside the case. If so, what kind of cable do you use for power, assuming you're not opening up the case to use the regular molex connectors?
- There is a specific eSata power cable you should use - assuming you have the correct eSata outlets on your system.
- Q: The computer is a Hp compaq.So I took the connector out of the computer but left it in the power socket.When I tried to reinsert the connector I hit the metal back panel of the computer and it made contact so I was wondering what is the part(s) that is likely to be broken?I want to know it so I can replace the damaged parts.Thanks in advance of your help.
- The power cable should have enough rubber/plasitc to stop contact with power supply directly unless you seen a spark I would try the a different cable. Is the power supply turned on? If it did spark and is turned on try swapping the power supply. Actually I missread, it touched the case itself so now you have to start swapping all parts starting with the power supply, then motherboard if that doesnt work. I hope you have some spare parks around. you could also take out the power supply and you will see a long 24-pin connector you can short the 1 green wire with a black one to see if the power supply turns on. The connector is a cable comming from the PSU not on the motherboard. And lastly each time you try to start the computer after swapping somthing only have the essentials to have it start. No CD drive extra HDD etc.
- Q: I have my Clearwire modem but have lost the power cable. Does anyone know what I would look for in a replacement power cable.
- check the Clearwire URL .. Support tab
- Q: Two weeks ago, my 1 yr 19 lcd monitor began to flicker? Why? The power cord and usb cable are secure?
- I've had a similar thing happen with my 17 GEM monitor. Eventually, I relocated the monitor and redid all the wiring and the flickering ultimately stopped. I'd wager it's a wire issue.
- Q: I just purchased and mounted my 52lcd and I cut holes to run the HDMI cables behind the wall. As I was snaking the power cable, I realized this might not be the best way. Is there anything I need to do (I only have basic 'contracting' skills) to keep my install fire code safe?
- Sorry dude you have me there... Running the power cable behind the wall is clear and ok but what has your install fire code got to do with running a cable behind a wall...??
- Q: I'd like to know what type of wire/specs. for a 3 phase high power cable that can handle a 41.6KVa that will be buried under the ground? The voltage will be a 220 volts in 60 Hz. could you show me how to calculate or any charts are really appreciated.
- There's not enough information in your question to give an exact answer. Figure the highest current in any of the phases assuming that your load may not be perfectly balanced or it may have a nonlinear current waveform. That will establish the minimum size of the conductors. Another factor to consider is the maximum allowable voltage loss at full current. You also need to know if voltage sags due to startup or inrush currents will be a problem. A long cable will need to have larger conductors to keep the losses within your acceptable range. Don
- Q: i just got a new motherboard but after reading throuhg the manual i coudnt get any instructions on which cable goes which way. pls i need some one to help me. all other connections are okay i suppose but afraid to just connect the power,and the reset button cable any how.
- With most motherboards there is only one way to attach the power cable to the board, otherwise it just wont fit. I believe there is a little notch on the cable which should line up with the notch on the board
- Q: I am using a Peavey Windsor half-stack that I've had for a little over a year now. It's 300 watts, 120 VAC (whatever that means), and 60 Hz. I lost the power-cable so I bought a new one, but I wanted to make sure there's no risk in using it. I'm pretty sure it's safe but I'd hate to overpower it if that's possible.
- It means that it has 300 watts of power . Thats a lot of power. 120VAC means that you connect it to a regular wall plug. If you can connect it to the amp and the wall socket , you got yourself an amp.