Low Frequency Transformer EI Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 500000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Features of Low Frequency Transformer EI Series
1. input:AC110V-250V 50-60Hz
2. Output:AC 3.0-800V
3. Modle:: EI series
4. CE,ROHS compliant, products are applying for CQC and ISO9001
Application of Low Frequency Transformer EI Series:
Home electronic appliances, communication instruments, medical apparatus, power tools, message armchairs and air-condition.
Common Electrical Paramenters
Specification
1. machine- inserted silicon steel with fire relardation
2. Flame Retardant Nylon Bobbin3
3. equipment: 3 EI type transformer lines, 4 sets of vacuum annealing furnaces
Normal EI Pin Transformer Specifications
Item | Core type | Output power(w) | Item | Core type | Output power(w) |
EI28 | EI28/8×12 | 0.5-1 | EI57 | EI57/19×30 | 16-32 |
EI28 | EI28/8×16 | 0.7-1 | EI57 | EI57/19×38 | 20-40 |
EI35 | EI35/9.6×10 | 0.2-0.8 | EI66 | EI66/22×22 | 17-35 |
EI35 | EI35/9.6×12.5 | 0.25-1 | EI66 | EI66/22×28 | 24-45 |
EI35 | EI35/9.6×16 | 0.4-1.7 | EI66 | EI66/22×35 | 36-58 |
EI35 | EI35/9.6×20 | 0.6-2.5 | EI66 | EI66/22×45 | 55-77 |
EI41 | EI41/13×13 | 0.6-2.3 | EI76 | EI76.2/25.4×25 | 65-88 |
EI41 | EI41/13×16 | 1-3.6 | EI76 | EI76.2/25.4×31.5 | 71-95 |
EI41 | EI41/13×21 | 1.6-5.5 | EI76 | EI76.2/25.4×40 | 70-97 |
EI41 | EI41/13×26 | 2.3-7.7 | EI76 | EI76.2/25.4×50 | 86-123 |
EI48 | EI48/16×16 | 2-5 | EI85.8 | EI85.8/28.6×29 | 70-95 |
EI48 | EI48/16×20 | 2.8-7.2 | EI85.8 | EI85.8/28.6×36 | 84-120 |
EI48 | EI48/16×25 | 4.6-11.1 | EI85.8 | EI85.8/28.6×46 | 105-154 |
EI48 | EI48/16×32 | 7-10 | EI85.8 | EI85.8/28.6×58 | 130-200 |
EI54 | EI54/18×18 | 5-12 | EI96 | EI96/32×40 | 100-150 |
EI54 | EI54/18×22.5 | 8-17 | EI96 | EI96/32×45 | 110-160 |
EI54 | EI54/18×29 | 11-25 | EI105 | EI105/35 | 500-700 |
EI54 | EI54/18×36 | 17-34 | EI114 | EI114/38 | 700-1000 |
EI57 | EI57/19×19 | 7-16 | All the output voltage and current are according to customers requirements. | ||
EI57 | EI57/19×24 | 14-21 |
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- First of all, make sure your power is too large, but you are not recommended to do so, the cost is too high, the pressure drop is too large, you can raise the voltage to 220V or higher, and then transfer to avoid power losses. If the direct transmission, the power is slightly larger, the line will be very rough, the cost will be very high
- Q: Why is the two side of the lighting transformer grounded?
- Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
- Q: The difference between lighting transformers and control transformers
- In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
- Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
- General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
- Q: Why is elevator lighting transformer installed?
- 1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
- Q: The transformer zero line has broken, has the result to the household illumination circuit?
- The lighting circuit mostly 3 phase unbalanced load, there will be zero drift, zero if the transformer line is broken, part of the lighting circuit to form a series of equipment in the case of two-phase circuit, circuit voltage is decreased and the lighting brightness is not enough, circuit voltage increases, the lamp burned;
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
- Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
- As long as the capacity of the transformer is enough, the voltage fluctuation of the line will be sure to occur when the high power equipment is started. Such fluctuations do not have much impact on the lighting.
- Q: Can the 500 volt lighting transformer be changed into an electric welder?
- 500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
- Q: Why can't autotransformer be used as transformer for safety lighting?
- When a fault occurs, leakage of electric leakage occurs, and the original coil is transmitted to the residents at high voltage, causing disastrous effects on the human body and property!
1. Manufacturer Overview
Location | Tianjin,China |
Year Established | 2002 |
Annual Output Value | US$5 Million - US$10 Million |
Main Markets | 18.00% North America 15.00% South America 13.00% Africa 13.00% Eastern Europe 5.00% South Asia 5.00% Central America 5.00% Western Europe 5.00% Eastern Asia 5.00% Mid East 5.00% Oceania 5.00% Southeast Asia 3.00% Southern Europe 3.00% Northern Europe |
Company Certifications |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Tianjin Port |
Export Percentage | 51% - 60% |
No.of Employees in Trade Department | 3-5 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 1,000-3,000 square meters |
No. of Production Lines | 5 |
Contract Manufacturing | OEM Service Offered Design Service Offered Buyer Label Offered |
Product Price Range | Low and/or Average |
Send your message to us
Low Frequency Transformer EI Series
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 500 Pieces pc
- Supply Capability:
- 500000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords