• Low Frequency Transformer EI Series System 1
Low Frequency Transformer EI Series

Low Frequency Transformer EI Series

Ref Price:
get latest price
Loading Port:
China Main Port
Payment Terms:
TT or LC
Min Order Qty:
500 Pieces pc
Supply Capability:
500000 Pieces per Month pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 

Features of Low Frequency Transformer EI Series 

1. input:AC110V-250V  50-60Hz 

2. Output:AC 3.0-800V 

3. Modle:: EI series 

4. CE,ROHS compliant, products are applying for CQC and ISO9001

 

Application of Low Frequency Transformer EI Series:

 

Home electronic appliances, communication instruments, medical apparatus, power tools, message armchairs and air-condition.

 

Common Electrical Paramenters

 

Specification

 

1.  machine- inserted silicon steel with fire relardation

 

2.  Flame Retardant Nylon Bobbin3

 

3.  equipment: 3 EI type transformer lines, 4 sets of vacuum annealing furnaces

 

Normal EI Pin Transformer Specifications 

Item

 Core type

Output power(w)

Item

Core type

Output power(w)

EI28

EI28/8×12

0.5-1

EI57

EI57/19×30

16-32

EI28

EI28/8×16

0.7-1

EI57

EI57/19×38

20-40

EI35

EI35/9.6×10

0.2-0.8

EI66

EI66/22×22

17-35

EI35

EI35/9.6×12.5

0.25-1

EI66

EI66/22×28

24-45

EI35

EI35/9.6×16

0.4-1.7

EI66

EI66/22×35

36-58

EI35

EI35/9.6×20

0.6-2.5

EI66

EI66/22×45

55-77

EI41

EI41/13×13

0.6-2.3

EI76

EI76.2/25.4×25

65-88

EI41

EI41/13×16

1-3.6

EI76

EI76.2/25.4×31.5

71-95

EI41

EI41/13×21

1.6-5.5

EI76

EI76.2/25.4×40

70-97

EI41

EI41/13×26

2.3-7.7

EI76

EI76.2/25.4×50

86-123

EI48

EI48/16×16

2-5

EI85.8

EI85.8/28.6×29

70-95

EI48

EI48/16×20

2.8-7.2

EI85.8

EI85.8/28.6×36

84-120

EI48

EI48/16×25

4.6-11.1

EI85.8

EI85.8/28.6×46

105-154

EI48

EI48/16×32

7-10

EI85.8

EI85.8/28.6×58

130-200

EI54

EI54/18×18

5-12

EI96

EI96/32×40

100-150

EI54

EI54/18×22.5

8-17

EI96

EI96/32×45

110-160

EI54

EI54/18×29

11-25

EI105

EI105/35

500-700

EI54

EI54/18×36

17-34

EI114

EI114/38

700-1000

EI57

EI57/19×19

7-16

All the output voltage and current are according to customers  requirements.

EI57

EI57/19×24

14-21

 

Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
First of all, make sure your power is too large, but you are not recommended to do so, the cost is too high, the pressure drop is too large, you can raise the voltage to 220V or higher, and then transfer to avoid power losses. If the direct transmission, the power is slightly larger, the line will be very rough, the cost will be very high
Q: Why is the two side of the lighting transformer grounded?
Neutral grounding of three-phase transformer is called working earthing: the main function is to strengthen the stability of low-voltage system potential, and to reduce the risk of overvoltage caused by grounding, high voltage, short circuit, etc..
Q: The difference between lighting transformers and control transformers
In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
Q: How to use digital multimeter to detect the quality of 36 volt low voltage lighting transformer?
General digital multimeter has a capacitor (some of the files with a million capacitance test table of Jack, some use pen)
Q: Why is elevator lighting transformer installed?
1) a lamp shall be installed at the highest and lowest point 0.5m away from the hoistway, and a light shall be installed at intervals not exceeding 7m, and a control switch shall be installed in the engine room and the bottom pit respectively;2) the lighting power supply for car top and hoistway shall be 36V; when 220V is adopted, the residual current action protector shall be installed;3) there is no lighting device for a closed well road with sufficient lighting conditions around the hoistway.
Q: The transformer zero line has broken, has the result to the household illumination circuit?
The lighting circuit mostly 3 phase unbalanced load, there will be zero drift, zero if the transformer line is broken, part of the lighting circuit to form a series of equipment in the case of two-phase circuit, circuit voltage is decreased and the lighting brightness is not enough, circuit voltage increases, the lamp burned;
Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
Q: Does the lighting work properly? Doesn't that power equipment start voltage unstable?
As long as the capacity of the transformer is enough, the voltage fluctuation of the line will be sure to occur when the high power equipment is started. Such fluctuations do not have much impact on the lighting.
Q: Can the 500 volt lighting transformer be changed into an electric welder?
500 VA transformer should not be used as an electric welding machine, so it is very difficult to reform the system, so it is better to buy a new electric welder
Q: Why can't autotransformer be used as transformer for safety lighting?
When a fault occurs, leakage of electric leakage occurs, and the original coil is transmitted to the residents at high voltage, causing disastrous effects on the human body and property!
Our company adopts advanced equipment, sophisticated production process and rigorous testing methods to ensure products meet quality standards. Based on the policy of survival on quality, relying on the credibility of the business and development, we will satisfy each customer with good quality and perfect services. We also hope to join hands with colleagues around the world to develop and make progress together!

1. Manufacturer Overview

Location Tianjin,China
Year Established 2002
Annual Output Value US$5 Million - US$10 Million
Main Markets 18.00% North America
15.00% South America
13.00% Africa
13.00% Eastern Europe
5.00% South Asia
5.00% Central America
5.00% Western Europe
5.00% Eastern Asia
5.00% Mid East
5.00% Oceania
5.00% Southeast Asia
3.00% Southern Europe
3.00% Northern Europe
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a) Trade Capacity
Nearest Port Tianjin Port
Export Percentage 51% - 60%
No.of Employees in Trade Department 3-5 People
Language Spoken: English, Chinese
b) Factory Information
Factory Size: 1,000-3,000 square meters
No. of Production Lines 5
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

Hot products


Hot Searches

Related keywords