Product Description:

Specifications: 

Model

GP9335C

Rectifier Type

6p

12p

6p

12p

6p

12p

6p

12p

6p

12p

Rated Nominal

120KVA/108KW

160KVA/144KVA

200KVA/180KW

300KVA/270KW

400KVA/360KW

Rated input voltage

380/400/415VAC 3-phase 4-wire

Rated frequency

50/60HZ

Input parameters 

Input voltage range

±25%

Input frequency range

45Hz~65Hz

Input soft start function

0-100%   5-300settable

Input power factor

>0.98(If harmonic filter is added)

Input harmonic current (THDi)

‹4.5%(If harmonic filter is added) 

Bypass 

Bypass voltage range

-20%~+15%

Bypass frequency range

50/60HZ±10%

Output parameters 

Inverter output voltage

380/400/415VAC 3-phase 4-wire

Voltage stability

±1%(Steady status),±3%(Transient status)

Frequency

50/60Hz

   Mains power synchronization window

±5%

Actually measured frequency accuracy (internal clock)

50/60Hz±0.01Hz

Output power factor

0.9(Output 90kW per 100kVA)

Transient response time

<5ms

Inverter overload capability

At 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s

 

Short circuit current from inverter

3ph 1.5ln for 5seconds,1ph 2.9ln for 5seconds

Maximum Bypass capability

1000% for 100ms

 

Phase shift

characteristic

With 100% balanced load

<1°

With 100% imbalance load

<1°

 

Total harmonic

Distortion(THDv)

100% linear load

<1%

100% non-linear load

<3%

System efficiency (full load)

Up to 94% (inverter efficiency is up to 98%)

Rectifier output parameters

Charger output voltage stability

1%

DC ripple voltage

≤1%

Operating environment 

Operating temperature range

0~40°C

Storage temperature

-25~70°C(Without battery)

Relative humidity

0~95% No condensation

Noise (1m)

58-68dB

Protection level

IP20

Standard

Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
You must know the quantity and power of the lamp to determine the transformer
Q:Lighting, lights, transformers, bulb brightness is too low, what's the matter?
Line light for safety light, voltage 24 volts and 36 volts, pay attention to the bulb and transformer voltage matching.
Q:How many 40W bulbs can be brought into the 1000VA lighting transformer?
The key is that the 220V terminals and 0 can not provide 1000VA capacity?
Q:The difference between lighting transformers and control transformers
In principle and construction, there is no difference between the two.The only difference is that the secondary coil output voltage is different.
Q:How many A leakage protection switches are used in 5000VA lighting transformers?
Line lighting transformer is suitable for AC circuit of 50~60 (Hz). It is widely used in electronic industry or industrial and mining enterprises, mechanical equipment, general circuit control power supply, safety lighting and indicator light power supply.
Q:Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
Q:The transformer zero line has broken, has the result to the household illumination circuit?
The zero line is connected to the transformer neutral point of transformer, three FireWire for its voltage is 220 volts, according to regulations, the total can not take the zero line fuse, switch, because once the zero line is disconnected, the rest of the line will no longer be a neutral line, into the use of electrical appliances connected to two the conductor, according to the characteristics of series circuit, each phase with electrical voltage, on load distribution, change the original load smaller which phase by using electrical appliances, will damage due to excessive voltage.
Q:How to calculate the rated capacity of small transformers for lighting purposes?
But in fact, consider the total load, the importance, the location of the machine, and the future additional plan, according to the following order.
Q:Why the 21 lighting transformer must double winding type safety isolating transformers, prohibited the use of autotransformer.
Double winding type safety isolating transformer is provided with two windings respectively as input and output (primary) winding (secondary) winding, and between the two windings are insulated from each other, only through the magnetic connection to the power supply, which is the secondary winding and the earth does not constitute a loop, if the use of additional electrical insulation, it should be safety isolating transformer.
Q:Can the 500 volt lighting transformer be changed into an electric welder?
The structure of the electric welding machine is different from that of the transformer, and the magnetic gap of the iron core can be adjusted so that the welding current can be changed. In addition, the output voltage of the welder is also soft
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications.if you have interesting, please kindly contact us! We will provide our good quality products and best services to you!

1. Manufacturer Overview

Location Guangdong,China (Mainland)
Year Established 2006
Annual Output Value US$10 Million - US$50 Million
Main Markets 9.09% North America
9.09% South America
9.09% Eastern Europe
9.09% Southeast Asia
9.09% Africa
9.09% Mid East
9.09% Eastern Asia
9.09% Western Europe
9.09% Southern Europe
9.09% South Asia
Company Certifications UPS CE UG/UX 1K; UPS CE (UG/UX) 2/3K; standards organisation of nigeria soncap; Soncap UX6K

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Shenzhen China
Export Percentage 61% - 70%
No.of Employees in Trade Department 11-20 People
Language Spoken: English, Chinese
b)Factory Information  
Factory Size: 10,000-30,000 square meters
No. of Production Lines 10
Contract Manufacturing OEM Service Offered Design Service Offered Buyer Label Offered
Product Price Range Low and/or Average