Lamp Cup with Leading Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 1000000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
series:
1,LED WIRE :diameter is 1.22mm to complete the seven stocks tinned copper wire , rated voltage is 330v . rated temperature is 105 . soft . white . UL certification line . the diameter of each stock tined copper wire is 0.127 mm . breakdown coltage is 2000v
2, SIZE: diameter--20mm height----45mm
3, INTERGRATED TEST : use a variety of materials mixed high voltage lamp power as onding filler material , suitaable for the high and low acess adapt to different environment . the surface of delicate , high hardness , excellent fire resistant , power loss and waterproff temperature pressure chemial resistance and other different problems
4, QUALITY ASSURANCE : environmental protection in line with ROHS directive requirements to provide ROHS test report
we producce the MR16-LED lighting empty cup of the same aesthetic that are not rough , excellent quality , high output , low pries , fast speed of production , prompt delivery , is an ideal choice to further the installation of the led board .
- Q: How many power illuminator can 5Kva 36V transformer drive?
- The load capacity of the transformer is 70% of its nominal power, so it is concluded that the transformer you provide can drive the 3.5KVA 36V lighting appliance (which is used in normal condition and environment)
- Q: What transformer can be used in a safety voltage lighting transformer?
- An isolated transformer is a transformer that is electrically isolated from an input winding and an output winding. The isolated transformer is used to avoid accidental touching of the charged body at the same time, and the isolation of the transformer is to isolate the current of the former side winding coil.
- Q: 1000 square meters low voltage.36 volts lighting power supply with multiple transformers and wires
- To 30VA/ square meters, the transformer needs 30KVA, with two 120 square copper wire. Specific should be used to determine the total power of the lighting transformer.
- Q: Why is the two side of the lighting transformer grounded?
- Single-phase transformer two side lighting to the ground, on the one hand is the lighting products now contain many semiconductor devices such as diodes, transistors, integrated circuits, semiconductor devices vulnerable to electrostatic damage, two side grounding contributes to the surge pressure factors produced by residual electrostatic discharge stay in the main circuit, avoid electrostatic protection, product life. In the 21 aspect, there is distributed capacitance between the two side and the primary side of the power transformer, and the high frequency surge disturbance caused by the primary side current source will directly enter the two side to the main circuit through the distributed capacitor. These unnecessary high frequency interference may jump into the sensitive signal source, make the control system malfunction, and the two side grounding of the power transformer can eliminate most of the undesirable effects of the distributed capacitance.
- Q: The difference between lighting transformers and control transformers
- A control transformer is a low voltage appliance, usually used as a power supply or part of a lighting for the control of electrical equipment such as machine tools. There are usually two different voltage outputs,
- Q: Is the substation separate from the power and illumination transformer?
- The power and lighting power supply in the substation need not be separated. In a large capacity power plant, the lighting can be electrically powered to ensure that the generator is stopped. The lighting source is often separated from the lighting transformer and powered by other power supplies.
- Q: Line lights, lighting transformers in use!! Can live line work?!! Be afraid of electric shock 40
- General line lights are 36 volts, especially in the damp and harsh environment, the light transformer adopts 24 volts voltage;After the use of light transformers, can generally live operations, first, low voltage, less dangerous, and the two is a transformer isolation, safety is greater, so you can live work, generally there will be no electric shock accident. (as long as the power is not in the hands and hands, the two end of the power supply, there will be no electric shock.)
- Q: 3 24V100W lights, I need to use a large capacity transformer (220V change 24V)?
- The bulb is used in the two luminescence tube combined type lamp holder, the calculation process is very complex. Different combinations, the secondary voltage is different. Because it is a DC ignition, but also consider the efficiency of rectification, but the total power is constant.
- Q: Why can't autotransformer be used as transformer for safety lighting?
- The main and auxiliary coils of the autotransformer have common parts. Once the short-circuit is made, the lighting circuit is directly connected with the high voltage circuit, which is very dangerous
- Q: Please tell me how to calculate the transformer in the lighting circuit of elevator shaft in building electrical design
- The previous elevator hoistway lighting required the 36V safety voltage, and you can see how many power lamps are required for the hoistway, and select the transformer
1. Manufacturer Overview
Location | Jiangsu,China (Mainland) |
Year Established | 2001 |
Annual Output Value | US$1 Million - US$2.5 Million |
Main Markets | North America; South America; Eastern Europe; Southeast Asia; Africa; Oceania; Mid East; Eastern Asia; Western Europe |
Company Certifications | ISO 9001:2000 |
2. Manufacturer Certificates
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability
a) Trade Capacity | |
Nearest Port | Shanghai,Ningbo,Lianyungang |
Export Percentage | 41% - 50% |
No.of Employees in Trade Department | 6-10 People |
Language Spoken: | English, Chinese |
b) Factory Information | |
Factory Size: | 5,000-10,000 square meters |
No. of Production Lines | Above 10 |
Contract Manufacturing | OEM Service Offered |
Product Price Range | Low and/or Average |
Send your message to us
Lamp Cup with Leading Wire
- Loading Port:
- China Main Port
- Payment Terms:
- TT or LC
- Min Order Qty:
- 100 Pieces pc
- Supply Capability:
- 1000000 Pieces per Month pc/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches
Related keywords