Copper Conductor XLPE Insulated Fixed-installed Fire-retardant Power Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Introduction:
The product applies for A.C supply & distribution system and is manufactured according to State Coal industry standard MT818.13-1999.Long-term service temperature of the cable conductor should not exceed 90℃.Max. temperature of conductor during cutting-out shall not exceed 250℃(max. duration 5S)..
Operating Characteristics:
ØRated Voltage:1.8/3~3.6/6kV
ØMin. Ambient Temperature: -40℃
ØNormal Operating Temperature:90~250℃
ØMin. bending radius is no less than 30 times of cable thickness
Specification:
Type and Description:
| Description |
MYJV | XLPE insulated ,PVC sheathed power cable for coal mine |
MYJV22 | XLPE insulated , steel tape armored , PVC sheathed power cable for coal mine |
MYJV32 | XLPE insulated , fine steel wire armored, PVC sheathed power cable for coal mine |
MYJV42 | XLPE insulated , heavy steel wire armored, PVC sheathed power cable for coal mine |
Cable Specifications:
Type | Cores | Rated Voltage kV | |||
0.6/1 | 1.8/3 | 3.6/6 6/6 | 6/10 8.7/10 | ||
Nominal cross-section mm² | |||||
MYJV | 3 | 1.5~300 | 10~300 | 25~300 | 25~300 |
MYJV22 | 3 | 4~300 | 10~300 | 25~300 | 25~300 |
MYJV32 | 3 | 4~300 | 10~300 | 25~300 | 25~300 |
MYJV42 | 3 | 4~300 | 10~300 | 25~300 | 25~300 |
Nominal Thickness of Insulation:
Nominal cross sectional area of conductor | Rated Voltage kV | ||||
0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 | |
| |||||
1.5 | 0.7 | — | — | — | — |
2.5 | 0.7 | — | — | — | — |
4 | 0.7 | — | — | — | — |
6 | 0.7 | — | — | — | — |
10 | 0.7 | 2.0 | 2.5 | 3.4 | — |
16 | 0.7 | 2.0 | 2.5 | 3.4 | 4.5 |
25 | 0.9 | 2.0 | 2.5 | 3.4 | 4.5 |
35 | 0.9 | 2.0 | 2.5 | 3.4 | 4.5 |
50 | 1.0 | 2.0 | 2.5 | 3.4 | 4.5 |
70 | 1.1 | 2.0 | 2.5 | 3.4 | 4.5 |
95 | 1.1 | 2.0 | 2.5 | 3.4 | 4.5 |
120 | 1.2 | 2.0 | 2.5 | 3.4 | 4.5 |
150 | 1.4 | 2.0 | 2.5 | 3.4 | 4.5 |
185 | 1.6 | 2.0 | 2.5 | 3.4 | 4.5 |
240 | 1.7 | 2.0 | 2.6 | 3.4 | 4.5 |
300 | 1.8 | 2.0 | 2.8 | 3.4 | 4.5 |
- Q: My brother took his PS2 over a friends, lost the cables, and then took mine. So now I have to go steal my cables back every time I want to play, or not play. My PS2 is a piece of crap, but I can't afford a new one. Can I buy replacemt AV and power cables? I saw a MadCatz one, but the reviews said it was terrible. Thanks!
- the ps2 power cable is a standard cable. You will be able to get this cheaply ( you do not need to buy one that specifically states it is for ps2) if it fits, it'll work. You can buy replacement av cables for the ps2. they are the same cables used for the ps1 and the ps3.
- Q: It's a mains electrical cable, like a kettle or computer, 3 pin but with a little groove under the 2 pins. Please help.
- If you are in the UK, it is 13amp insulated, power cable with live, neutral and earth wires.
- Q: i have a sata hard drive that i wont to put in an older mb. i purchased an adpater but i do not know what the larger sata cable if for. there is no place to put it.
- One cable is the power cable and one is the data cable, just like IDE drives have two cables for the same purpose. You will need to have a 4-pin molex to SATA power cable connector and also a hard drive controller card with a SATA port on it for you to be able to connect the drive. If you don't have both of these, you won'e be able to hook up the drive at all.
- Q: Basically i want to add another ssd using a power splitter cable, however i was wondering if you could use the power splitter cable with the optical drive instead of with the current hard drive, (im asking this as there's no room to place the ssd drive close to the hard drive)Thanks
- Yes it will work just fine.
- Q: Electrical equipment installation project "power cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area, such as 3 × 25mm2 refers to 25mm. 75mm2 or cable cross-sectional area of 490mm2? More
- Said cross-linked polyethylene insulation, double steel armor, PVC outer jacket. Voltage level 0.6 to 1 kV, 5 core, cross section 10 square millimeters. About four centimeters in diameter.
- Q: W22 in the cable on behalf of what
- Oh, not W it should be VVVV22 is the meaning of plastic insulated plastic sheath with armored copper cable
- Q: I have a simple 400watt amp going to a single 10inch kicker sub, nothing crazy. I need to know what gauge of power cable would be safe. An 8 gauge for example...
- Hi . 8 gauge is fine for now . Just some advise its better to invest a little more and get a 4 gauge cos with sound u always want more if later u want to upgrade then you have already got your 4 gauge cable installed .
- Q: Hello,I recently bought a kotatsu and I really need some help. The power cable is of course Japanese And I need some type of converter.On the part of the cable that plugs into the radiotaor it says:PSE (It's in some square box)JET MR7A 250VOn the end that plugs into the wall it says:PSE (It's in some square box)JET MR7A 125VI''m not sure if a simple small converter to let me put the Japanese cable into my wall is enough, I think I need something extra to make sure nothing goes into flames.Inside the Japanese instruction manual I found some info However, I'm not really sure if it is related to the power supply or notAC100V 50-60Hz400W3.1 (Probably the length of the cable) 1.3 (Same here I think)140Wh 60 Wh55C 37CPlease help me, what should I get to be able to use the cable in Europe. Any links at all will be helpfulThanks.
- Don't worry too much about what the cord says. Worry about the power requirements on the appliance label, and making sure you are feeding it with the voltage required, with a capacity within the range. In your instance, you will need a converter transformer that converts your outlet voltage to 100V, and has 550 or larger watt capacity.
- Q: I have a be quiet! dark power pro 850W. The sleeving is too thick for cable management!! It is a complete mess with the antec 900. its ridiculous as I bought it with cable management in my mind. Can I buy thinner cables on their own? Is there a standard modular fitting size?Thank you.
- I got the Coolmaster 1000, all the cables bar the main are disconnecting, very handy plus they supply you with all the cables you will ever need to make a monster of a system.
- Q: I have a Netgear router and just now when I tried to plug the power cable back into the back of it, it would fit. I look more closely and it seems that the metal end of the power cable may be slightly bent. But I'm still confused because it's bent at the end of the metal, and even though the very tip of it isn't bent, that part still won't even slide into place a little. Could anyone help me in resolving this issue?
- If it is the correct adapter for the router and it fitted before, gently force it and it will comfortably fit eventually. There is probably a reason it doesn't fit now (it has been pulled out with some force) so I would suggest getting a new power adapter for it if the above does not work
Send your message to us
Copper Conductor XLPE Insulated Fixed-installed Fire-retardant Power Cable
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 100 m
- Supply Capability:
- 30000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
Hot products
Hot Searches