Item specifice:

Insulation Material: pvc

Product Description:

Factory Price High Quality PVC sheathed XLPE insulated power cable

1The cable is made of copper line with PVC insulated, and PVC/XLPE sheathed, the cable of the wire is strand. The voltage is 600/1000V; the color of the cable can be any color as your need. The cable is widely used in construction, industry and other sites, the cable can be used overhead, underground.

2. Certificates of the cable: ISO, CE, RoHS, CCC.

3. More related products:

copper conductor FEP insulated FEP sheathed power cable

4. Products list and parameter

                

No.

Size

Specification

Length per roll

PVC insulated non-sheathed copper wires BV (450-750 Voltage)

1

1.5 mm2

1×1.38 mm2

100 m

2

2.5 mm2

1×1.78 mm2

100 m

3

4 mm2

1×2.25 mm2

100 m

4

6 mm2

1×2.76 mm2

100 m

5

10 mm2

7×1.35 mm2

100 m

6

16 mm2

7×1.70 mm2

100 m

7

25 mm2

7×2.14 mm2

100 m

PVC insulated PVC/XLPE sheathed Twin cables with/without earth

BVVB (300-500 Voltage)

8

2×1 +1 mm2

2×1.13 +1.13 mm2

100 m

9

2×1.5 +1 mm2

2×1.38 +1.13 mm2

100 m

10

2×2.5 +1.5 mm2

2×1.78 +1.38 mm2

100 m

11

2×4 +2.5 mm2

2×2.25 +1.78 mm2

100 m

12

2×6 +4 mm2

2×2.76 +2.25 mm2

100 m

13

2×10+4 mm2

2×7×1.35 +2.25 mm2

100 m

14

2×16+6 mm2

2×7×1.70 +2.76 mm2

100 m

PVC insulated non-sheathed Multi flexible wires BVR (450-750 Voltage)

15

1.5 mm2

7×0.52 mm2

100 m

16

2.5 mm2

19×0.41 mm2

100 m

17

4 mm2

19×0.52 mm2

100 m

18

6 mm2

19×0.63 mm2

100 m

19

10 mm2

49×0.52 mm2

100 m

20

16 mm2

49×0.63 mm2

100 m

PVC insulated PVC/XLPE sheathed copper cables (Lower than 1000 Voltage)

No.

Size

Specification

21

3×2.5 mm2

3×1.78 mm2

22

3×4 mm2

3×2.25 mm2

23

3×4+1×2.5 mm2

3×2.25+1×1.78 mm2

24

3×4+2×2.5 mm2

3×2.25+2×1.78 mm2

25

3×6 mm2

3×2.76 mm2

26

3×6+1×4 mm2

3×2.76+1×2.25 mm2

27

3×6+2×4 mm2

3×2.76+2×2.25 mm2

28

3×10 mm2

3×7×1.35 mm2

29

3×10+1×6 mm2

3×7×1.35+1×2.76 mm2

30

3×10+2×6 mm2

3×7×1.35+2×2.76 mm2

31

3×16 mm2

3×7×1.70 mm2

32

3×16+1×10 mm2

3×7×1.70+1×7×1.35 mm2

33

3×16+2×10 mm2

3×7×1.70+2×7×1.35 mm2

34

3×25+1×16 mm2

3×7×2.14+1×7×1.70 mm2

35

3×25+2×16 mm2

3×7×2.14+2×7×1.70 mm2

36

3×35+1×16 mm2

3×7×2.52+1×7×1.70 mm2

37

3×35+2×16 mm2

3×7×2.52+2×7×1.70 mm2

38

3×50+1×25 mm2

3×10×2.52+1×7×2.14 mm2

39

3×50+2×25 mm2

3×10×2.52+2×7×2.14 mm2

40

3×70+1×35 mm2

3×14×2.52+1×7×2.52 mm2

41

3×70+2×35 mm2

3×14×2.52+2×7×2.52 mm2

42

3×95+1×50 mm2

3×19×2.52+1×10×2.52 mm2

43

3×95+2×50 mm2

3×19×2.52+2×10×2.52 mm2

44

3×120+1×70 mm2

3×24×2.52+1×14×2.52 mm2

45

3×120+2×70 mm2

3×24×2.52+2×14×2.52 mm2

46

3×150+1×70 mm2

3×30×2.52+1×14×2.52 mm2

47

3×150+2×70 mm2

3×30×2.52+2×14×2.52 mm2

48

3×185+1×95 mm2

3×37×2.52+1×19×2.52 mm2

49

3×185+2×95 mm2

3×37×2.52+2×19×2.52 mm2

50

4×2.5 mm2

4×1.78 mm2

51

4×4 mm2

4×2.25 mm2

52

4×4+1×2.5 mm2

4×2.25+1×1.78 mm2

53

4×6 mm2

4×2.76 mm2

54

4×6+1×4 mm2

4×2.76+1×2.25 mm2

55

4×10 mm2

4×7×1.35 mm2

56

4×10+1×6 mm2

4×7×1.35+1×2.76 mm2

57

4×16 mm2

4×7×1.70 mm2

58

4×16+1×10 mm2

4×7×1.70+1×7×1.35 mm2

59

4×25 mm2

4×7×2.14 mm2

60

4×25+1×16 mm2

4×7×2.14+1×7×1.70 mm2

61

4×35 mm2

4×7×2.52 mm2

62

4×35+1×16 mm2

4×7×2.52+1×7×1.70 mm2

63

4×50 mm2

4×10×2.52 mm2

64

4×50+1×25 mm2

4×10×2.52+1×7×2.14 mm2

65

4×70 mm2

4×14×2.52 mm2

66

4×70+1×35 mm2

4×14×2.52+1×7×2.52 mm2

67

4×95 mm2

4×19×2.52 mm2

68

4×95+1×50 mm2

4×19×2.52+1×10×2.52 mm2

69

4×120 mm2

4×24×2.52 mm2

70

4×120+1×70 mm2

4×24×2.52+1×14×2.52 mm2

71

4×150 mm2

4×30×2.52 mm2

72

4×150+1×70 mm2

4×30×2.52+1×14×2.52 mm2

73

4×185 mm2

4×37×2.52 mm2

74

4×185+1×95 mm2

4×37×2.52+1×19×2.52 mm2

75

5×2.5 mm2

5×1.78 mm2

76

5×4 mm2

5×2.25 mm2

77

5×6 mm2

5×2.76 mm2

78

5×10 mm2

5×7×1.35 mm2

79

5×16 mm2

5×7×1.70 mm2

80

5×25 mm2

5×7×2.14 mm2

81

5×35 mm2

5×7×2.52 mm2

82

5×50 mm2

5×10×2.52 mm2

83

5×70 mm2

5×14×2.52 mm2

84

5×95 mm2

5×19×2.52 mm2

85

5×120 mm2

5×24×2.52 mm2

86

5×150 mm2

5×30×2.52 mm2

87

5×185 mm2

5×37×2.52 mm2

 

5. Package: mainly the cables are packed in steel-wooden drum, the length is on the size and weight, but also the cables can be packed as your demand.

copper conductor FEP insulated FEP sheathed power cable

copper conductor FEP insulated FEP sheathed power cable

copper conductor FEP insulated FEP sheathed power cable

7. The workshop

Looking forward to co-operate with you!





Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:IDE HDD to SATA PSU no power cable?
this is what you want. The IDE power cable your referring to is actually called a molex connector. IDE is the type of data interface the hard drive uses (the wide cable).
Q:Why did my power supply entrance burn and the cable too?
A dodgy power cable can very easily singe or burn the power socket on the computer. In general, the lighter the cable, the more dodgy it is. $2 is nothing - I would buy a more expensive cable. The cents you save isn't worth it when your house is on fire. It's impossible to know whether your power supply or other computer components suffered any damage because of the electrical fire. You could try testing with a multimeter, but you should probably replace the power supply at a minimum.
Q:Shall i use directly Nikon S550 digi camera U.S. power cable in India?
India power outlets run 220v, not 120, so you are going to need a converter or a completely new power-supply.
Q:amp goes into protection mode and power cables get hot?
yeah you probably need bigger hots and grounds your wires should never get hot
Q:power cables and amp question..?
250 watt power cord? Where are the fuses which are being blown? Maybe you put in the wrong fuses or the wrong amperage fuse.
Q:Is it ok to play my PSP using the power cable instead of the battery?
It is fine. The PSP is just telling you that it is taking power from the outlet instead of the battery.
Q:I'm moving--how far in advance to set up power, cable, etc?
You okorder.com to compare electricity and cable or satellite rates. The cheaper the rate the less you pay :) I have personally never had to pay a deposit even when I was in college. They check your credit for outstanding balances on utility bills and base your deposit if any on that.
Q:2 GAGE POWER CABLE TO HOT!!!!?
Too hot means the current is very high. Probably in excess of 200 amps. I suspect there is a short in the amp, specially if you tried to connect it hot and drew a spark. That will kill a lot of electronics. .
Q:Guitar Amp Power Cable Snaped..?
Hahaha, that is THE most basic DIY ever. Ok go to you local hardware store and get maybe 4 foot of similar wiring, look around for what you want, get home, open up the back of your roland, find where the chord was wired, should be either soldered or clamped, undo these and attach the new wiring, if your cheap you could just take the plug head of the original cable and attach it to where the cable broke, and you'll just have a shortened power cable.
Q:Where do i put the power cable of a video card on the Motherboard?
You use an open power plug from the power supply. If there isn't an extra one, you need a splitter.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range