butterfly valve VitonStandardSize: DN40-DN1200 Place of Origin: China (Mainland)

Ref Price:
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
1 pc
Supply Capability:
9999 pc/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Quick Details

Standard or Nonstandard: Standard Structure: Butterfly Pressure: Low Pressure Power: Manual Material: Casting Temperature of Media: Normal Temperature Media: Water Port Size: DN40-DN1200 Place of Origin: China (Mainland) Wafer type: butterfly valve Packaging & Delivery

Packaging Details: Plactic bag+Paper cover+Plywood cases 

Delivery Detail: Within 20 days 

Specifications

Wafer type lined butterfly valve 

1.Design standard:ISO,BS,API 

2.DN40-DN1200 

3.PN10/PN16/PN25 

4.Center lined disc 



Wafer type lined butterfly valve 


 


 


Technical Data


DN40-DN1200mm PN1.0-1.6MPa


General Design:ISO 5752 / BS 5155 / API 609


Body: Cast Iron, Ductile Iron, Carbon Steel, Stainless Steel


Seat: EPDM, PTFE, NBR,Viton


Stem: Stainless Steel, Steel,


Disc: Ductile Iron with Nickel Coating,Ductile Iron with Nylon Coating, Stainless Stee 304/316l, Alu-Bronze,Duplex steel


Flange Connection:DIN,ANSI,JIS,BS


 


Product Features


Wafer type flanged body style fit between FF or RF flanges


PTFE bushing ensure the maximum shaft support and centralized alignment


360°polished disc assures positive on-off


Hard-Backed Cartridge seat or Edge-Boot seat


The pin,spline or square connection are all available


Universal ISO 5211 mounting pad.

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:When will Butterfly Valves be used?
Butterfly valve has the advantages of simple structure, easy operation, small footprint and light weight;1, for the city water supply network in general, DN300 still DN300 valve, butterfly valve above, this installation is convenient (especially large diameter valve installation is inconvenient, the weight of large volume, big);2, there are sediment pipeline, such as powder, mud and other mixed substances;
Q:Check valve; flexible joint `; installation order of electric butterfly valve
Connect the Songjiang rubber joint from the pump outlet. Check the 1 valve
Q:What is the working principle of the electric butterfly valve, and what's the difference between the butterfly valve and the butterfly valve?
Signal butterfly valve is generally can achieve full clearance of a valve opening electrical signal output, the general requirements of the electrical signal isPassive electric shock signals are mostly used in fire fighting systems, such as the need for valve position feedback;The electric butterfly valve is not necessarily the signal butterfly valve, because the electric butterfly valve does not have the requirement of the source contact.
Q:Three eccentric hard sealing butterfly valve, why not fit in the end of the pipe?
The sealing ring will hold up. It does not fit in with the flange end of the pipeline, this addition is the most common and convenient pipeline after purge and easily add pipeline.
Q:Butterfly valve flow direction is single or two-way?
To see your butterfly type low voltage soft sealing clamp / flange butterfly valve is a two-way flow; and high pressure valve seal to choose clip / flanged butterfly valve, these are single direction flow, the valve body is provided with a flow indicator! There are so many factors that you have to say, such as working conditions, pressure, temperature, design concept and so on.
Q:What's the use of fire butterfly valve?
Its working principle is as follows:1, the signal butterfly drive by the worm gear drive shaft and butterfly plate rotation, realize the opening and closing and control flow.2, rotating worm gear drive handwheel, so that the butterfly plate to open and close and adjust the flow of purpose, hand wheel clockwise rotation for the valve closed.3. The worm gear drive box is equipped with micro switches in two forms:A, in the gear box body is provided with open and close direction two microswitches, respectively, when the valve fully open and close action, connected to the control room "valve open" valve off "light source, to accurately display the switch state of the valve.B, the transmission device is arranged in the box body the microswitch (disc position close to 0 degrees), when the butterfly plate from 0 degrees to 40 degrees when the position of a micro switch, the output valve closed signal, 40 degrees to 90 degrees when the position of another pair of normally closed output valve opening signal. A cam that adjusts the touch microswitch and shows the different positions of the disc.The fire in the fire that is the switch signal butterfly valve in the pipe network, because the fire pipe water must be kept clear, so as to ensure the timeliness of fire, so the signal valve once closed, will tell the host signal module alarm, fire control network notify the monitoring center is closed.
Q:toyota mechanic valve adj 1.8l?
valve adjustment . you need to know the fire order. the gage between the stem. rotators the cranshaft. it could be cold start. cylinder need to be bottomed center.
Q:How many kinds of butterfly valves are there?
1. according to the structure classification (1) Central sealing butterfly valve (2) single eccentric sealed butterfly valve (3) double eccentric sealed butterfly valve (4) three eccentric sealed butterfly valve2., according to the sealing material classification (1) soft sealing butterfly valve. (2) metal hard sealing butterfly valve.3. according to the form of sealing classification (1) forced sealing butterfly valve (2) pressure sealed butterfly valve.4. classification according to working pressure (1) vacuum butterfly valve. 2) low pressure butterfly valve. (3) medium pressure butterfly valve. (4) high pressure butterfly valve. (5) ultra high pressure butterfly valve.5. classification by working temperature (1) high temperature butterfly valve. (2) medium temperature butterfly valve. (3) normal temperature butterfly valve. (4) low temperature butterfly valve. (5) ultra low temperature butterfly valve.
Q:Ok, My zone-valve is dead. How do i find/fix it?
You may have only one circulate pump on the boiler. If you want to check the zone valve there is a small handle on the valve you can lift up and this will open the valve manually. It will be found on the (usually) green valve on the return end of the copper pipe. It should have a red and white wire attached. If this is opened manually and you get heat you can replace the top half of the valve by twisting it off and exchanging it with a new one. I think they are around $35.00 bucks or so at Home depot. You can keep it open without and fear. This means you will only have a one zone boiler and all baseboard s will get heat instaed of being zoned
Q:What is the principle of butterfly valve and check valve? Any difference?
Direct water butterfly valve, check valve is to water can not flow valve

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range