Borehole Deep Well Submersible Pumps with high quality and performance
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
Product Description:
Application:
It is suitable for offshore platform fire-fighting, thermal dissipation, seawater desalinization, seawater lifting, coastal square fountain, mariculture and attemperation as ground source heat pump in coastal area. It also can lift underground drinking water and mineral water,etc.
Material:
QH series stainless steel submersible pump has several kinds of material.
Seawater and strongly corrosive medium: austenitic stainless steel 316, 316L, tin bronze,etc.
Moderately corrosive medium: austenitic stainless steel 304,etc.
Advantages:
CNC lathe precision machining ensures parallelism and perpendicularity of all the castings.
With rigorous testing, well installation and full load performance test, you can feel easy to use it.
Some of our products manufactured by introducing the Germany Ritz technology, improving the pump’s efficiency and making it more energy-saving & environment-friendly.
Motor parameter:
The motor is accord with GB/T2818-2002 pump industry standard, and it is lubricated by water. The motor must be filled with water. The standard length of the extended cable is 3m.
If you need special requirement, we can extend its length. The working temperature should be a little higher than that of common motor because of its poor magnetic conductivity.
Power:
The general power specification we supply you:380v/50Hz±5. We also can provide customised specifications at your requirements. The variation of voltage and frequency ratings and its influence on motor performance and temperature should meet the requirements of GB755(National Standard)
Notes:
We can provide you the suitable products if the actual working condition, the voltage or the frequency are not consistent with above specifications.
Working condition:
The motor should be submerged into water with the depth no more than 70m;
Solid content (mass ratio): ≤0.01%
Refer to the technical agreement to learn more parameters.
- Q: Why does the centrifugal pump close the pressure to start?
- Therefore, the operation rules of multistage centrifugal pumps require that the inlet valve be opened before opening, and the outlet valve is closed. However, the export valve closed time can not be too long, because at this time the medium in the pump cycle, the medium temperature gradually increased, easy to cause mechanical seals, due to lack of lubrication friction and wear or damage.
- Q: What are the important parameters of the pump?
- Pump parametersFlow rate QFlow is the amount of liquid (volume or mass) that is pumped out in unit timeVolume flow is expressed in Q units: m3/s, m3/h, l/s, etc.
- Q: What are the causes of pump shock?
- Troubleshooting cause1. bearing damage, replace new bearings2., coupling pin, bolt damage, rubber column or metal bolt wear, change
- Q: What is cavitation, centrifugal pump cavitation phenomenon how to solve?
- First, what is cavitation?:When the centrifugal pump shell has air, it produces less centrifugal force because the density of the air is much smaller than the density of the liquid. Thus, suction pressure at the entrance to the top of the tank liquid level and pump is bad enough to the liquid storage tank into the pump, the centrifugal pump self suction capability, the centrifugal pump can not transport liquid, this phenomenon is called "cavitation".When a liquid drops at a certain temperature to the vapor pressure at that temperature, the liquid produces a bubble. The phenomenon of producing bubbles is called cavitation. When the cavitation bubbles, flow to the high pressure, the volume of reduced, so as to burst. This due to the pressure of rising bubbles disappear in the liquid in the phenomenon called cavitation bubble collapse.
- Q: Why should I pump the pump before starting the centrifugal pump?
- Before the operation of the centrifugal pump, the pump must be filled with water, exhaust the air, before you start the operation. All centrifugal pumps should be handled this way, which is the centrifugal pump itself.The way of water diversion:1., in the centrifugal pump outlet increase water diversion pump (usually using vacuum pump), start the centrifugal pump before, start the vacuum pump, the centrifugal pump air into;2. increase the vacuum water tank before the intake of the centrifugal pump to meet the working conditions of the centrifugal pump;3. in the centrifugal pump inlet water increase valve, to meet the working conditions of centrifugal pump;4., if the water tank or water tank volume of water level is higher than the centrifugal pump position, the first operation of the front row empty, usually do not empty, you can use.
- Q: What's the difference between non negative pressure and variable frequency water pump?
- When peak water is used, the fluctuation of water pressure will be the same for customers! Because the key to the fluctuation of hydraulic pressure is the flow rate of the pump and the lift of the pump. As long as the flow of the selected pump is large enough, the tank is large enough, the lift head is suitable, and the pressure fluctuation is relatively small. And the selection of non negative pressure and frequency conversion pump group is not directly related. If the municipal tap water pressure and water sufficient (large enough diameter), the use of non negative pressure is better. If the municipal tap water pressure and water shortage, you can only use the frequency converter pump + water tank, no negative pressure can not be used.
- Q: Why does the centrifugal pump start and close first when the outlet valve is closed?
- The operation rules of centrifugal pump strictly required to close the outlet valve before the shutdown, boot and then slowly open the outlet valve, regulating pipeline pressure and current range. The reason is: the centrifugal pump in the startup process in order to avoid large starting current caused by electrical faults, such as circuit breaker tripping,
- Q: How high can the pneumatic diaphragm pump be?
- Diaphragm capacity, high temperature, pneumatic diaphragm pump ability, high temperatureMany users do not know how high the temperature resistant diaphragm pump, diaphragm pump either electric diaphragm pump or pneumatic diaphragm pump products it cannot do without diaphragm attachments, diaphragm materials mainly fluorine rubber, rubber, rubber, polyether road three EPDM, PTFE several, if not considering the gas temperature resistant diaphragm made of stainless steel. The temperature to 600 degrees of diaphragm pump diaphragm pump, but must use the diaphragm, so the diaphragm pump can Naiduo high temperature depends entirely on the diaphragm was affected by temperature, following to share various diaphragm pump diaphragm material and different material temperature choice diaphragm pump product right:
- Q: What are the conditions required for hydraulic pumps to complete oil absorption and compression?
- 2, the change of working volume is periodic, and in each cycle, the oil absorption process is changed from small to big, and the process of oil pressure is changed from large to small;3, suction oil cavity must be separated from each other without interference.
- Q: No negative pressure water supply equipment, both the main pump and auxiliary pump, power is not the same, how to choose the control cabinet?
- Non negative pressure variable frequency water supply means no negative pressure superposed water supply equipment. When running, it is connected directly to the water supply pipe. Always test the pressure of tap water pipe network and water supply pipe network pressure control system, when the water pressure is lower than the pressure required by the user, the frequency conversion device based on water automatically control the pump speed through the steady flow compensator of water balance, maintain a constant pressure water supply. In the multi pump system, the control system can automatically dispatch the water pump according to the water consumption. It can balance the working time of the pump and ensure the pressure of the water supply. When the water supply pressure satisfy the required pressure, the system automatically stops the pump by the external water supply pipe network directly. CJWFG-DYG non negative pressure superposed water supply system:
Send your message to us
Borehole Deep Well Submersible Pumps with high quality and performance
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1 unit
- Supply Capability:
- 1000 unit/month
OKorder Service Pledge
OKorder Financial Service
Similar products