• Three-way Control Valve Made In China Best Price System 1
  • Three-way Control Valve Made In China Best Price System 2
Three-way Control Valve Made In China Best Price

Three-way Control Valve Made In China Best Price

Ref Price:
get latest price
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 pc
Supply Capability:
1000 pc/month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing

 1.Features Of Three-way Control Valve

Three-way Mixing(Diverting)ControlValves are used in exchanger to adjust the fluidtemperature. High precision and performance. Divertingtype that divides the flow into two directions and mixingtype that converges two flows into on are availiable.

This product complies with the GB/T4213-2008standards.

2.Specifications Of Three-way Control Valve

TypeThree-way, cast globe valve
Nominal sizeDN25~450mm
Rated CV value6.3~3100
Pressure rating

ANSI150~600

PN1.6~6.4MPa

End connectionsFlanged:FF、RF、RJ、TG、MFM
Body & Bonnet MaterialSCPH2/WCB,SCPH21/WC6,SCS13A/CF8,SCS14A/CF8M,SCS16A/CF3M,Ti and other alloy steels .etc.
Trim Material

SUS304,SUS304+Stellite,SUS316,SUS316+Stellite,SUS304L,SUS316L,Monel,

Hastelloy C .etc.

Rangeability30:1
Flow characteristicsLinear,EQ%
LeakageANSI Class IV
Actuator

HA Pneumatic Diaphragm type

VA/VP  Cylinder piston type

EIL  Electronic type

M8  Intelligent type

3.Body Of Three-way Control Valve

 

TypeThree-way, cast globe valve
Nominal size25、40、50、65、80、100、125、150、200、250、300、350、400、450mm
Pressure ratingANSI Class 150, 300, 600;JIS 10K, 20K, 30K,40K; PN 1.6, 4.0, 6.4 MPa *
End connectionsFlanged:FF、RF、RJ、TG、MFM
Body & Bonnet MaterialSCPH2/WCB,SCPH21/WC6,SCS13A/CF8,SCS14A/CF8M,SCS16A/CF3M,Tiand other alloy steels.
Bonnet type

(P) Plain type :-17~+230℃

(EI)Extension Type I:-45~-17℃ and +230~+566℃

Gland typeBolted gland
PackingTeflon V-ring、 Grafoil
GasketFlat type, Saw-tooth type (Carbon steel, Stainless steel or other alloy steels)
Painting colorMunsell N-6(Epoxy resin group)is standard. In the case of stainless steel body, nopainting is standard.

 

4.Images Of Three-way Control Valve

Three-way Control Valve Made In China Best Price

 

5.Applications Of Three-way Control Valve

Three-way Mixing(Diverting)Control Valves are used in exchanger to adjust the fluid temperature. 

 

FAQ

Q1:How Can I Get A Sample?
A1:You can get samples by communicate with our export sales.
Q2:How Long Is Delivery?
A2:Delivery time will be30-45days according to order quantity.
Q3:What Is The MOQ?
A3:MOQ depends on different items.
Q4:What Is Our Normal Payments Terms?

 

Q:hello I am having trouble inflating my back wheel tube. so i guess i will just tell you what happened. well i came back from the bike shop with a presta valve adapter and i put it on my tube. it fills up too near full psi but just after a ride around the block it is flat. i have no idea why. please help me! also its a mavic tube 700 x 23, vittoria rubino pro 700 x 23 tire, and a vuelta xrp 17 deep v back wheel. thanks!
Did you take the adapter off? It is only intended to fill the tire, you take it off and close the valve.
Q:ok im buying a kx 125 from 96 and he said the only problem with the bike is that it has a small oil leak around the power valve too me it sounds like a gasket. but i want someone elses opinion on what else it could be.
The kx125 actually has 3 valves in the exhaust, a main, a left-hand one and a right-hand one. Each is fitted with o-rings which require disassembly in order to be reached. This would also be a good time to clean the power valves since they tend to become encrusted with carbon deposits which interfere with their normal operation.
Q:will adding a bypass valve onto an air filter effect gas milage or horsepower?
bypass valves are for cars with forced induction IEturbocharger,supercharger it allows the air that would normally be expelled into the atmosphere blow off valve and instead putting it back into the intake which helps with less lag in building boost again. If your car is not turboed or supercharged then forget it.
Q:Or is our money stinky? is the $59 we paid not equivalent to that paid by xbox360 ps3? Please help!! I am sick of getting killed every 5 minutes. Is VAC false advertising?
Well first off Activision fired infinity ward so chances are slim to none (they hired Bungie, guys who created halo).. valve doesnt have a thing to do with the game and generally Activision are lazy asses so id count the chances around 1 in 100
Q:when heater heats water there is a small leak thru the releif valve. need answrers to possible reasons for malfuntion. leak is not continous.
SHUT OFF WATER AND REPLACE RELIEF VALVE, IF YOU HAVE HARD WATER IT CAN ACCUMULATE LIME AND FORCE VALVE TO OPEN. ALSO HEATING ELEMENT MIGHT BE BAD AND WATER HEATER IS OVER HEATING. VALVE SHOULD RANGE FROM 150 TO 210 PSI NOT 30 PSI.
Q:I have been diagnosed with a bicuspid aortic valve and a discrete stenosis under the valve at 11 years old. I am now 25. My cardiologist told me I might need a valve replacement a 70. Can people actually live long with that condition? I don't understand it. And he only wants me to have an ultrasound every 3 years because nothing has changed in the past 10 years. Can my condition change in a short time? At a dangerous level? I have bad anxiety because of this.
The mitral valve between the left atrium and left ventricle only has two cusps and it works fine. Since the valve going into the left ventricle has two valves, it stands to reason that a similar valve going out of the left ventricle would function similarly if it was the same size and shape. The number of cusps is not entirely related to how well the valve functions. In your case, the opening of the aortic valve is slightly smaller than normal, but clearly capable of passing an adequate amount of blood. The stenosis alone may be the only problem caused by the valve. The stenosis you have likely creates some back pressure when the left ventricle contracts. The heart compensates partly for the back pressure but this prolonged compensation wears on the heart valve a little more than normal. So, you end up with a heart that more or less functions normally but the back pressure and compensation cause the heart valve to wear out faster than normal. Its a gradual effect. The type of damage done from this circumstance is not something that changes rapidly. Evaluating the condition every three years is still probably a very cautious approach and its not certain that the stenosis will ever become a significant problem even if you live well beyond 70 years.
Q:I threw a birthday party last night, all went well until 2am when a crazy (drunk!) lady cut all the wires from my heating system (i guess as a prank??? dunno, she is never invited back). I have everything up and running when using one thermostat and connecting the thermostat wires (red directly to tv, Brown directly to W, and white directly to T) and not using the two Honeywell zone valves (model number V8043F. How do I connect those two zone valves to the L8148E aquastat?The valves have on bottom Th-TR, TH and TR and the two top screws are labeled end switch.If you need photos I can take them :)Thanks in advance!
The zone valves should have 4 wires, 2 yellow and 2 red.The yellow wires are connected to the 24 volt thermostat circuit in a series. The corresponding thermostat turns the motor on, opening the zone valve, closing the end switch and turning on the boiler and the pump. The red wires are the end switch wires. They are just wired together in parallel and anytime at least one opens, it turns the boiler/pump on. Now, you must have one of the Tstat wires going to the boiler, when it calls for heat, it turns the boiler/pump on. You probably have the zone valves locked in the open position. So you will have heat all over the house but just not as much control as you had when you were running individual zones. But, you know what? Your system would be more efficient if you left the zone valves locked open and ran the system from one thermostat! To make it even better, you can run the circulation pump all heating season long ( just wire it direct to 120v) and just use the thermostat to turn the boiler(burner) on when there is a call for heat. If one zone or the other is too hot, try turning a valve down on the return line(if you have valves) to balance the heat. Hope this is not too complicated and hope to help!...................................
Q:Someone explained on chevy that valve guide clearance can limit lift.
The measurement between the valve stem and valve guide which is the drilled machined hole in the cast iron cylinder head. .0015 - .0018 is the usual valve guide to valve stem clearance.
Q:I have rented a house and the irrigation timer only has wires of one zone.It goes to a single valve then out to a big round cover with 6 zone pipes coming out of it. What the heck kind of set up is this?does it do a mechanical rotation inside that cover? the zones only come on one at a time but every time I turn it on I get a different zone as they are all Zone 1 on the timer.
The single valve is the master control valve. It shuts the system down at the end of the irrigation cycle. It's a safety element in case one of the zone valves doesn't close or close completely. The other valves are probably digitally addressable. Your timer opens the master control valve and then digitally selects each zone valve in turn and waters according to a programmed cycle. These systems are called irrigation sequencers. Some of them are wireless.
Q:Can you please explain to me what an atrial valve is and what it does??
You're incorrectly combining two parts of the human heart, atrium(atria) and valves. The human heart has four chambers, two superior ATRIA and two inferior ventricles. The atria are the receiving chambers and the ventricles are the discharging chambers. The pathway of blood through the human heart consists of a pulmonary circuit and a systemic circuit. Blood flows through the heart in one direction, from the atria to the ventricles, and out of the great arteries, or the aorta for example. This is done by four VALVES which are the tricuspid valve, the mitral valve, the aortic valve, and the pulmonary valve

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Hot Searches

Related keywords