Pure Copper BV Electric Cable BV Cable with Good Quality

Ref Price:
Loading Port:
China main port
Payment Terms:
TT OR LC
Min Order Qty:
1000 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

1.Cable Introduction:

Standard: BS6004 / IEC227

1)Standard

GB 5023.11997 , JB 8734.15-1998, Q/ZEL 02-2002, GB 5023.17-1997,  IEC60227

 2) Rated Voltages:

 300/500V    450/750V   (600/1000V also available)

 3) Application

The products is suitable for use in power installations, fixed wiring or flexibleconnections for electrical

 appliance like lighting,  electronic equipment,  instrument and communication equipment  with rated 

voltage 450/750V or less!

2. Specification

Nominal
  sectional area
  mm2

Conductor
  No/Dia.mm

Nominal
  Insulated thick
  mm

Max overall
  Dia.mm

Condcutor
  Resistance at20

Min insulated
  resistance at
  70MΩ/km

Cu

Al

1.5

1/1.38

0.7

3.3

12.1

-

0.011

1.5

7/0.52

0.7

3.5

12.1

-

0.010

2.5

1/1.78

0.8

3.9

7.41

11.8

0.010

4

1/2.25

0.8

4.4

4.61

7.39

0.0085

6

1/2.76

0.8

4.9

3.08

4.91

0.0070

10

7/1.35

1.0

7.0

1.83

3.08

0.0065

16

7/1.70

1.0

8.0

1.15

1.91

0.0050

25

7/2.14

1.2

10.0

0.727

1.20

0.0050

35

7/2.52

1.2

11.5

0.524

0.868

0.0040

50

19/1.78

1.4

13.0

0.387

0.641

0.0045

70

19/2.14

1.4

15.0

0.268

0.443

0.0035

95

19/2.52

1.6

17.5

0.193

0.320

0.0035

120

37/2.03

1.6

19.0

0.153

0.253

0.0032

150

37/2.25

1.8

21.0

0.124

0.206

0.0032

185

37/2.52

2.0

32.5

0.099

0.164

0.0032

3. Packaging & Delivery

Packaging Details:

1) Packing Lengths: 100m/roll, 200m/roll,   305m/roll. Other lengths available according to client's Request; 2) Inner   packing: Wooden reel, plastic reel. 3) Outer packing: Carton box, pull box,   pallet. 4) Other packing available according to client's Request.

Delivery

15days or as per your request

4. Pictures:

Nominal
  sectional area mm2

Conductor
  No/Dia.mm

NominalInsulated thick mm

Max overall Dia.mm

Condcutor Resistance at20

Min insulated
  resistance at
  70MΩ/km

1.5

1/1.38

0.7

3.3

12.1

-

0.011

1.5

7/0.52

0.7

3.5

12.1

-

0.010

2.5

1/1.78

0.8

3.9

7.41

11.8

0.010

4

1/2.25

0.8

4.4

4.61

7.39

0.0085

6

1/2.76

0.8

4.9

3.08

4.91

0.0070

10

7/1.35

1.0

7.0

1.83

3.08

0.0065

16

7/1.70

1.0

8.0

1.15

1.91

0.0050

25

7/2.14

1.2

10.0

0.727

1.20

0.0050

35

7/2.52

1.2

11.5

0.524

0.868

0.0040

50

19/1.78

1.4

13.0

0.387

0.641

0.0045

70

19/2.14

1.4

15.0

0.268

0.443

0.0035

95

19/2.52

1.6

17.5

0.193

0.320

0.0035


Pure Copper BV Electric Cable BV Cable with Good Quality

Pure Copper BV Electric Cable BV Cable with Good Quality


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:A sub-eight splitter, behind the link ONU equipment, which also need to add fiber patch panels, or can be directly connected?
Cable and 10kV power line parallel laying the minimum distance of 0.5 meters.
Q:Have a question about compatible replacement power cable for Dell Optiplex 790 SFF, HELP please! 10A vs 3.6A will it ruin computer?
Thanks David for your expertise!
Q:Can i use an AC power cable in place of an ordinary 2-wire telephone cable?
telephone wire is twisted pair.. which reduces interference, and induction problems... using electrical cable in place of phone cable would work but not without acting like an antenna and picking up all kinds of back ground interference... as well as potentially degrading the signal for your DSL...
Q:Can you use any power cable with any amp?
It means that it has 300 watts of power . Thats a lot of power. 120VAC means that you connect it to a regular wall plug. If you can connect it to the amp and the wall socket , you got yourself an amp.
Q:Would a 196w a/c power cable work on a T.V. that needs a 190w? Thanks in advance!?
okorder
Q:What is the use of wire and cable per square meter of residential building?
Generally wear SC65 tube. If the distance is too long, elbow and more, then the choice will be larger.
Q:Why my power supply gives a squeezing noise when i plugged in the power cable and computer does not turns on?
ROFLMAO What's a squeezing noise?!?
Q:Bass guitar amplifier cables help!!?
Abes okorder.com... All you need is a standard guitar cable to connect the bass to the amp.
Q:Stripping 4 gauge power cable?
I use a knife to strip that wire, just be careful not to nick the wire. Drill a hole and use sheet metal screws to screw the fuse holder down.
Q:is it safe to solder a power cable?
safe if you do it correctly but not recommended as there is too much chance for problems that could cause a fire later, if the joint came apart or the tape dried up. .

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range