Parallel Volume Bundle Aerial Insulated Cable

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT or LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Products Introduction:

Parallel Volume Bundle Aerial Insulated Cable (Parallel Volume Bundle wire) is a product popularized and applied in the fifteenth scientific planning of the rural grid construction by the national electric power company. The scientific staff in our company borrowed the experience of applying the wiring harness from abroad, on the basis of which they successfully developed this product by improving and designing its technique and structure, filling the blankness of this product.

The reactance in low-voltage power-supplying circuit is composed of  impedance, capacitive reactance, and inductance. Parallel Volume Bundle  wire supplies power through three-phase and 4-wire, so as to minimize  the imbalance of three-phase load and to reduce the neutral wire  current, thereby reducing the resistance consumption. As a result of  using the compact symmetrical split structure, the wire inductance  lowers, and the dielectric constant between the lines is increased,  electricity capacity increases and the reactance is significantly  reduced so as to achieve the purpose of expanding the capacity and  reducing the  loss eventually.

    As the wires are bundled as a volume, the tensile strength has  been greatly increased than a single one, thus reducing the possibility  of single-phase getting broken. When suffering tensile force such as  wind pressure and frost, the insulation between parallels is not under  pressure, thus enhancing the operational safety factor and distinctly  improving the effects of preventing against thunder, electricity  stealing and leakage. The fissility of the volume makes it easy for the  interconnection between branches and convenient for transfiguration and  combination. Marked by the zero wire, it is clear to identify the  sequence of phase, thus mistakes can be prevented. The connection of the  parallel volume bundle wire uses fewer poles, horizontal bars and  porcelain materials, saving a lot of metals. As insulation can reduce  the height of the poles and can not be influenced by such complex  environments as trees and compounding, the wire can be laid along the  walls, thoroughly without poles, thus lowering the project cost. In  addition, compared with single wire, it makes the construction more  convenient and is more labor-saving and time-saving, thereby reducing  the construction expenses. Compared with the pattern of ordinary aerial  naked wire, the parallel volume bundle wire is advantageous in that its  operational cost is low and it has obvious long-term interests.  

Characteristics of the products:
    Relatively low circuit loss, with 5% - 10% loss.
    Making constructions convenient, time-saving and labor-saving and fixing expenses lower.
    Having great tensile strength when combined and highly safe to prevent filching and leakage of electricity.
     Lowering the cost of project and reducing the need of poles, horizontal  bars and porcelain materials and also reducing the height of poles.

Standards of the products:
    GB12527-90 rated voltage and below 1 kv aerialcable insulation.
    State  Power Corporation of the Ministry of Agriculture, "parallel cluster  aerialcable insulation optional technical conditions"

Product Categories classifications of the products
     The sub-conductor materials: parallel cluster aerial cable insulation  have Tongxin, Lvxin two. According to the materials of the conductor,  Parallel Volume Bundle Aerial Insulated Cable has copper core and  aluminum core.
    By insulating material at: parallel cluster  aerial cable insulation is weathering of PVC (PVC), weathering of  polyethylene (PE), according to insulated materials, Parallel Volume  Bundle Aerial Insulated Cable can be divided into PVC, PE, and XLPE.
Cross-linked polyethylene (XLPE) insulation of three.
     By sub-type structure: the parallel cluster aerial cable insulation is  square (BS1), Star (BS2) peace-(BS3) three. According to the structure,  Parallel Volume Bundle Aerial Insulated Cable can be divided into BS1,  BS2 and BS3.

    Note: (1)Conductor: Copper or Aluminium (2) joint rib: PVC or PE or XLPE (3)Insulation: PVC or PE or XLPE

 

Specification:

TYPE

TITLE

CORES

CROSS-SECTIONAL AREA

BS0 –JKV-0.6

BS0 –JKY-0.6/1

BS0 –JKYJ-0.6/1

Copper core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv

 

4

 

2.5-70

BS0 –JKLV-0.6/1

BS0 –JKLY-0.6/1

BS0 –JKLYJ-0.6/1

Aluminium core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv

4

4+1

4-25

35-120

BS0 –JKV-0.6

BS0 –JKY-0.6/1

BS0 –JKYJ-0.6/1

Copper core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv

 

2

 

2.5-70

BS0 –JKLV-0.6

BS0 –JKLY-0.6/1

BS0 –JKLYJ-0.6/1

Aluminium core Parallel Bunched Aerial Insulated Cable with rated voltage 0.6/1kv

 

2

 

4-120


Main product performance


NO.

 

ITEM

 

UNIT

REQUITEMENT OF PERFORMANCE

PVC

PE

XLPE

 

  1

Original capability: tensile strength: min

Mpa

12.5

10.0

121.5

Elongation at break: min

%

150

300

200

 

 

 2

Air-oven aging test: temperature

80±2

100±2

135±3

Air-oven aging test: time

h

168

240

168

tensile strength: min

 Mpa

12.5

--

--

tensile strength: change rate

%

±20

--

+25

Elongation at break: min

%

150

300

--

 

3

Change rate at break

 %

±20

--

+25

low temperature elongation test: temperature

-35

--

--

low temperature elongation test: Elongation at break

 %

20

--

--

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Power cable ZRYJV-4x70 + 1x35 What does it mean?
2 cable in a variety of environments in the laying of the layout, spacing should meet the design requirements
Q:Subwoofer/Amplifier Power Cable Help!?!?
The fuse isnt mandatory but its a good thing to have if your drawing alot of power then you will need it ive blown like 4 then i upgraded no more blown fuses but ya you should get one
Q:Can I buy a 6 pin power cable and plug it in to the wall?
You cannot plug it into the wall. Its too sophisticated. A single GTX 295 requires a 700-watt PSU with a 50 Amp 12v rail. Insane power consumption going on here. Upgradable to quad-SLI (woo). If you can afford a GTX why can't you afford the PSU? A PSU regulates your power and protects your equipment from voltage spikes etc. Get the PSU. Whats wrong with your 4850? can your board support a x-fire setup (two 4850s linked?) That'd be cheaper in the long run.
Q:My cable box will not show power?
I have a Scientific 2200 and it won't power on either. I've tried everything. It happened 2x in the last week. The other time it came back on by itself after a little while. This time -nothing. Tech is coming tomorrow. Better be bringing a new box......
Q:What to do if a power cable fell in my driveway?
No, call the power company.
Q:Why does my Xbox 360 Power Cable not fit into the socket?
THAT CABLE YOU HAVE ARE FOR THE NEWER VERSIONS OF XBOX360 ....THE OLDER 360'S HAVE JUST THE PINS NO MIDDLE IF U BOUGHT IT USED YOU SHOULD JUST TELL EM TO EXCHANGE THE POWER CABLE OR BUY ANOTHER POWER CABLE FOR OLDER VERSION
Q:Will ps2 power cable work on ps3?
No, you can use the power cable for a computer on the PS3. It is a standard shape and can be purchased from any good computer shop. The PS2 uses a transformer and the pin alignment is different. Just get a proper cable, they are really cheap anyway.
Q:Is there a hdd power cable with a MALE 4-pin connector that extends into one female 4 pin connector and one..?
Probably, but most people just buy Molex to SATA power adapters. If you need more Molex 4 pin plugs, just buy some Y splitters. Any computer store worth a darn should have some of both in stock, even the chain ones.
Q:where do i run an amplifier power cable to the battery in a 2001 mitsubishi eclipse?
you have to find a hole in the firewall and make your way through.. I have an 02 explorer, i found a plastic cap where some electrical wires went through to the engine, so i drilled another hole in the cap, (very carefully) and used a rubber washer to seal the gap. Make sure you dont leave any gaps in your firewall, and avoid drilling a hole in the actual firewall AT ALL COSTS!! hope that helps!
Q:Did I just damage my power supply with a 300V power cable?
If you plugged a power cable running 300V then there definitely is a risk that you damaged the power supply. However I think you mean you plugged in a power cord with a rating of 300V. This simply means the power cord is designed to tolerate this much voltage. It would be difficult for a domestic user to have access to 300V - in the UK the domestic voltage is 240V, in the US 120V So no you haven't done any damage

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range