Product Description:

Specification of Air Diffuser

Supplying Air Diffusers 

-Frame Thickness: 1.0mm /0.8mm
-Any Size be customed 
-Powder Coated RAL 9010/9016

-1-4 curved blade air diffusers

  

Usage of Air Diffuser

The grille is suitable for ceilling  sidewall, soffit or cill mounting and may be used for supply or extract applications. 

Typical installations include offices, shops, hotels and most commercial or industrial buildings.

Available as standard in white polyester powder coat finish. 

Other polyester powder  coat finishes are also available as an option.

 1

Item

HVAC aluminum air conditioner grille

 2

Materials

Extruded Aluminum alloy (6063-T5)

 3

Blade

Blades in 45°from aluminum profile or as customer’s requirements

 4

Bar spacing

30mm as standard or as customer’s requirements

 5

Materials

0.8mm, 1.0mm, 1.2mm, 1.5mm or according to the customers’ 

 6

Surface Finish

Powder coated, Anodized , PVDF, Mill finish.

 7

Size 

Width x Height, any sizes available

 8

Powder for Finish

Environmental protection and non-toxic, and Color to keep 5 -10 years.

 9

Color

Refer to RAL colors swatch or customized colors available

 10

Design

Drawings designed according to the customers’ requirements

 11

Payment terms

T/T, L/C, PYAPAL, etc.

 12

Delivery time

Usual 15-20 work days for a 40GP container 

 13

Package details

Bubble wrap + Cartons for FCL,  Bubble wrap + Cartons + Wood-box for 

 14

Mesh

Stainless steel security mesh, Aluminum security mesh

 15

Type

Fixing and adjustable installation



Products show

HVAC Related Square air Vent Diffusers steel & aluminium

HVAC Related Square air Vent Diffusers steel & aluminium

HVAC Related Square air Vent Diffusers steel & aluminium


Production line

HVAC Related Square air Vent Diffusers steel & aluminium

 

FAQ of Air Diffuser:

 

1, What's size do u have for round type diffuser?

A: We have face size from 150mm to 550mm,neck size from 250mm to 400mm

 

2, Do u still have other types ?

A: Yes, we have round diffuser/ rectangle diffuser/ linear grilles/ baseboard diffusers,etc

 

3, What's the most early delivery time?

A: Within 25 days for each 40'fcl

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:Do you want to turn off the water return switch when the geothermal pipe is exhausted?
General water separator exhaust valve is a common part of the internal structure of the cone is a spiral helium-type push-buoyed red berry rifles along the fortress Kunjin cut off a class, which is very simple, no gasket spring and the like parts. Exhaust drip after the micro-drip does not matter, if the leakage is serious, may be sealed with the surface of foreign matter into the impact. The specific operation is as follows: first on the water valve and sub-catchment control valve closed, and then unscrew the exhaust valve bolts, clean and clean inside and outside the thread, and finally reset the bolt, open all the valves.
Q:What kind of equipment is the protection of the fan coil in the ground source heat pump?
Ground source heat pump systems are durable and highly reliable. Contains less mechanical parts, and all mechanical parts are not buried in the ground is installed inside the house, which makes the equipment from external damage. Underground buried pipeline has 50 years of service life. Ground source heat pump system is very quiet, so that the environment inside and outside the house are very pleasant. Ground source heat pump system is no noisy fan equipment, whether in the courtyard or near the courtyard, will not affect the outdoor activities. Ground source heat pump system is safe and reliable. Since no instruments are exposed to the outdoors, children or pets are protected from damage and damage to external equipment. Ground source heat pump systems do not have open flames, flammable fuels or potentially hazardous fuel storage tanks. Plumbing geothermal is closed through the water under the floor of the cycle to the temperature of hot water to increase the temperature of the indoor temperature, do not close the doors and windows, and the head of hot head in line with human health, the body is very comfortable.
Q:What is the geothermal decoration process?
Process: 1, in the case of the ground flat before the first with about 5MM of benzene board will be all the pavement covered with the ground. 2, in the benzene board covered with a layer of insulation film. 3, in the insulation film laying geothermal tube. Here need to pay attention to, every square meter should be laid around the heat pipe 5M can not have any joints. The spacing between tubes and tubes should be appropriate at 20CM. 4, after the completion of geothermal pipe laying on the top of the hourglass (that is, sand sands save things). 5, finally, in the above with about 1: 5 cement mortar leveling. (Absolutely can not be calendering, otherwise affect the cooling effect. I will not say the first brick) Note: 1, geothermal company's choice. Congratulations, hidden projects do not save, we must choose a qualified, strong, good reputation, professional and strong, rich experience in the construction of geothermal companies, signed a formal contract. This is the decisive condition for ensuring the quality of the project. 2, the choice of geothermal pipe. Do not be confused by the low offer, geothermal pipe quality of the good and bad, a direct impact on the life of geothermal engineering, the choice of good quality underground pipe, floor components (including water separator, valves, filters, etc.). Step back, even if the future quality problems, the pipe manufacturers will have some compensation. 3, the choice of the best parts of the ground are all qualified quality copper parts. Geothermal engineering underground part of each road must be a complete tube, can not take any form of connection In fact, after the cement mortar filled with what pipe is not important (but can not use too rubbish). In fact, when the shop is most afraid of heat resistance (air resistance: that white is the tube in the air). So in the shop when the heat, especially immediately before the backfill must let the workers carefully check the good.
Q:Toshiba home central air conditioning how?
Now the central air conditioning to do is good in Japan, such as Daikin, Hitachi, Toshiba, Mitsubishi Electric, Mitsubishi heavy child twist twist thieves Lou Lou Lou workers, etc., are very good Japanese goods. To be made, then Hisense is good, Hisense can be comparable with Hitachi
Q:What kind of heater? Home electric heater how to choose
Home heating or the use of electric heating is good, like a small sun to the fast, but no heat.
Q:How to use the Beretta boiler
Any boiler before starting the machine to pay the water to see if the water pressure gauge pointer is between 1 - 1.5bar. If the water pressure in the above range, open the gas pipe valve, power on, set the machine in the winter position, set the heating temperature, usually the upper limit of the floor heating temperature can be set to 55- -60 degrees Celsius, radiator heating up to 75-85 degrees Celsius (if the radiator is not anti-hot protection, it is best to set the temperature a little lower). After normal ignition do not have to ignore it. Bath: see the water pressure gauge pressure is normal, open the gas valve, power on, set the machine in the summer position (if it is winter, that is set in the winter position), the hot water temperature is set at 42-45 degrees Celsius Between, open the hot water head, until the water temperature is appropriate and stable after you can start bathing. Antifreeze: water pressure gauge pressure is normal, the machine power plug (do not boot), the gas path open (must ensure that the gas source) can be. The above operation applies to Faroe, Haas, Ariston, Bosch, Squirrel, Beretta and other brands of boiler
Q:Is not to warm the total valve opened on the line, do not control the room valve
Not to warm the total valve is to ensure that the sub-catchment water supply. If the total valve is also open to see whether the automatic temperature control or manual. If it is manual to ensure that each sub-catchment water supply back to the water supply of small valves are in the open state, if it is automatic temperature control with the temperature control panel control actuator, set their own on the line. General temperature adjustment Manual adjustment of water supply back to the water below the small valve, automatic temperature control on the adjustment panel. The general test performance through the porphyrin shortage of stupid Wei Han Li back to the water pipe heat is not hot to know this road opened not open.
Q:1200 square meters of villas need much electric heating stove
Have you considered heating it?
Q:Casing head test pressure process
Test pressure 1. Test pressure single test pressure and system test pressure, single test pressure: after the completion of the trunk pipe or hidden parts of the pipeline installation is completed according to the design and specification requirements for water pressure test. System test pressure: heating system installed according to the design and specification requirements for system water pressure test. 2. Heating, air conditioning system test procedures: a first check the entire system of all control valves are open, the system should be separated from the outer pipe network, open the gas tank release valve. B will be the water main pipe, test pressure pump and other temporary pressure test pipe connected to the main water supply pipe, and irrigation to the system, to be filled with water system and cutting ingot Cui melon Chaozhao sleep bile duct system After the discharge of the air, the release of the valve out of the water so far), close the release valve; c operation test pump to boost, boost the process should pay attention to check management, fittings and accessories are leaked, such as seepage Leakage should stop the pressure to suppress, and after the buck to repair, change pad, tighten and so on. D system without leakage, the pressure and boost to the test pressure, stop the pump check, and observe the pressure gauge, requiring 10 minutes pressure drop of not more than 0.02Mpa, that is qualified.
Q:New to buy a house, construction area of 120 square meters, do not understand to warm, do not know what to warm, how the cost?
New to buy a house, construction area of 120 square meters, I heard that the installation of warm, do not understand to warm, do not know what to warm, how the cost?...

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range