• High Tensile PC Steel Wire with Spiral Ribs System 1
  • High Tensile PC Steel Wire with Spiral Ribs System 2
  • High Tensile PC Steel Wire with Spiral Ribs System 3
High Tensile PC Steel Wire with Spiral Ribs

High Tensile PC Steel Wire with Spiral Ribs

Ref Price:
get latest price
Loading Port:
Tianjin
Payment Terms:
TT OR LC
Min Order Qty:
200 m.t.
Supply Capability:
20000 m.t./month

Add to My Favorites

Follow us:


OKorder Service Pledge

Quality Product, Order Online Tracking, Timely Delivery

OKorder Financial Service

Credit Rating, Credit Services, Credit Purchasing


1、Structure of High Tensile PC Steel Wire with Spiral Ribs Description:

    Prestressed Concrete Steel Wire, also named PC steel wire orPC wire, is made from high carbon steel with low relaxation high tensile strength. PC wires are sorted into plain surface PC wire, spiral ribs PC wire and indented PC wire. They are commonly used for concrete structure reinforcement such as highway, high-speed railway projects, large-span bridges, overhead crane beam, coal mines.



2、Main Features of High Tensile PC Steel Wire with Spiral Ribs:  

Perfect cohesion. Spiral ribs and indented surface can strengthen the bond between wire and concrete, thus it improves the performance of the PC products and extends its life.

Low relaxation high tensile strength. With low relaxation 2.5% and tensile strength up to 1860Mpa.


3、High Tensile PC Steel Wire with Spiral Ribs Images:




4、High Tensile PC Steel Wire with Spiral Ribs Specification:

Quick Details

  • Steel Grade: 77B or 82B high carbon wire rod

  • Standard: GB

  • Wire Gauge: 4.0mm to 10.0mm

  • Place of Origin: Tianjin, China (Mainland)

  • Type: PC

  • Application: Construction

  • Model Number: 4.0mm to 10.0mm

Packaging & Delivery

Packaging Details:Each coil is strapped by steel bands and fully wrapped in anti-rust paper & P.P woven sheet.
Delivery Detail:within three week after confirm the order or contract.


The character of the spiral ribs wire is there are 3-6 protruding ribs on the surface.

    The new product was invented by Silvery Dragon in 1991, and the research program of the product includes spiral drawing die, spiral deforming technique etc. 12 proprietary technologies. The product is characteristic of 3 to 6 spiral ribs through spiral deforming drawing on the surface of wire, increasing the bond ability with concrete and raising PC products properties. Since 1997, spiral rib PC wire has already fully took place of indented PC wire, and it has been applied in PC telegraph pole, PC hollow floor plate, PC sleeper, high-speed railway PC sleeper plate, PC water supply pipe etc. Since 1996, it has already been exported to the overseas market. In 2006, the product passed the examination and certificate on the properties by German TU Munich; now the product is applied by Great Britain, Ireland, Bangladesh, German, Poland, etc. more than 30 countries. The production of the product is according to Chinese GB/T5223-2002. Except the shape, other standards for mechanical properties are interchangeable with those popular in the world, or we can use the reasonable standard after consulting with customers.


5、FAQ of High Tensile PC Steel Wire with Spiral Ribs: 

How is the quality of your products?
Our products are manufactured strictly according to national and internaional standard, and we take a test on every pipe before delivered out. If you want see our quality certifications and all kinds of testing report, please just ask us for it.
Guaranteed: If products’ quality don’t accord to discription as we give or the promise before you place order, we promise 100% refund.


How about price?
Yes, we are factory and be able to give you lowest price below market one, and we have a policy that “ for saving time and absolutely honest business attitude, we quote as lowest as possible for any customer, and discount can be given according to quantity”,if you like bargain and factory price is not low enough as you think, just don’t waste your time.Please trust the quotation we would give you, it is professional one.

Why should you chose us?
Chose happens because of quality, then price, We can give you both.Additionally, we can also offer professional products inquiry, products knowledge train(for agents), smooth goods delivery, exellent customer solution proposals.Our service formula: good quality+good price+good service=customer’s trust
SGS test is available, customer inspection before shipping is welcome, third party inspection is no problem.

Any question, pls feel free to contact us !


Q:Wire 1 and wire 2 are made from the same metal. Wire 2 has a larger diameter than wire 1. The electric field strengths E1 and E2 are equal. A) Compare the values of the two current densities. Is J1 greater than, less, or equal to J2?B) Compare the values of the currents I1 and I2. Is I1 greater then, less or equal to I2?
The current will be more dense in the smaller wire. The value of the current is inversely proportional to the resistiance of the wire. Resistance = resistivity * length / Area since the wires are of identical material and length, the only thing left to vary is the cross-sectional area. Area is proportional to the square of the radius (diameter), so the current will be proportional to the square of the diameter. I2 is proportional to I1^2 I2 is larger than I1 .
Q:There are 3 wires where the old floodlight used to be and only 2 wires attached to the floodlight I want to install. How can I tell which wires connect to which... and what is the third wire?
Usually there is a black wire (hot), a white wire (neutral), and a green or bare wire (ground)... in an ideal world:) If you need to find the hot wire, you can get a non contact voltage finder from lowes or the hardware store. This device will tell you where the AC voltage source is coming from without you even touching the wire. You will need to remove the old light and wire nut the wires. Then turn the electricity back on, use the detector to find out which wire is hot. Connect the black wire on the lamp to the hot wire.
Q:how do I wire the generator so it can spin 360 on the pole with out snapping the wires.... Thanks
You need some ring contacts and brushes that will be touching those rings that will be spinning while the generator does to complete a circuit without twisting wires. Make sure you get the right size rings and wire for the amount of current
Q:I have just bought a Clarion CZ500 and am trying to run a remote wire to the amp. Where do i connect the wire to the head unit? Please Help
On the 16-pin connector coming from the rear of the head unit, there's a blue/white wire terminated with an insulated female slide connector. You can crimp a male connector to your amp remote wire or simply cut the connector off and splice the wires together. The wiring diagram is on page 31 of your manual.
Q:ok so i have 3 questions.i have an oldsmobile cuttlas supreme and i have a 0 gauge power wire that is 17 feet is that long enough???? and i have 0 gauge ground that is 17 feet is that long enough....and about the speaker wire..i have 8 gauge speaker wire that is 25 feet..is this a good setup.make sure u answer all these questions please thank you..
that sounds plenty fine.
Q:Can you swap out a 1984 Porsche 944 wiring harness with a different car's wiring harness? If which car. Thank you.
You can order a new 944 wiring harness, but it is a lot of work. Much easier is to just get a good manual with a wiring diagram, and replace only the damaged wires, splicing at little as possible, as you go. I assume you just have some heat cracked wires, unless you had a fire or something? You can't take the harness from another car because all the connectors are going to be the wrong type, gender, or location. Especially things like the brainbox harness plug, etc.
Q:Wired car radio no sound powered on then wires crossed had to run red straight to battery. Then memory and ground crossed. Now nothing. Checked fuses radio fuse is bad. Will i also need a new wiring harness? Stereo Works fine when hooked up to battery charger.
Yeah i had them all wired together right i didnt tape them off cause i was trying to see if there was a bad speaker or something and.the.ignition wires hit.the.ground so i ran it straight to the battery cause i thought the ignition wire shorted out in harness then i was told to check radio fuse.
Q:Can anyone give me some info or a website with info on which type of wire carries sound waves best?
Wire does not carry soundwaves, at least not unless the ends of the wire have tin cans on them, and the wire is pulled taut between them! Wires can carry electrical signals which can be used to reproduce the sounds that caused them. This is how sound comes from such as your stereo system's speakers. Maybe that's what you actually mean? If so, copper wires (insulated, of course) are what you want, and if the distance you run the wires is great, the heavier the wire (gauge) the better. If you are transmitting high power to speakers, the wires have to be capable of handling the electrical current involved.
Q:6000+ heat sinc wires?i up graded my cpu and the new heat sinc has a 4 wire conector and my old 3800+ heat sinc has 3 and mobo has 3 pin processor works great. sys recognizes amd 6000+ dual core processor @ 3.0 ghz but not the model #???? sys works great scored 10143 on 3DMARK 06 anyway the fan and temp s are all good any ideas what the other wire is
Yes, the fan on your heat sink has a fourth wire that..............(tune back in tommorrow folks, for the conclusion), (sorry, somebody's telling jokes over here!) The fourth wire is a Speed control wire. The first wire,(Red), is 12VDC,(power), the second,(Black), is the ground, should be a Blue wire, for rpm sensor, and the fourth,(color codes vary), is the wire that the BIOS uses to speed the fan up when the temp of the cpu raises, slows the fan down, when it isn't used as hard. Temp of the cpu, is found through one of it's pins on the bottom of it.
Q:Okay, I just started tearing into my partially finished basement of the home I bought last week. Some of the electrical wiring is interesting to say the least.I have a junction box in the basement. One wire connects directly to the panel, another out to an outlet, and the third goes up and out to half the house. All of this is 14/2 except the quot;thirdthat runs up and out. This is wired with 14/3 but the third wire isn't connected to anything. Should I be concerned considering every outlet in the house works?
That spare wire (red) in the 14-3 is just that. A spare. Just keep the wire-nut on the end of the wire and you'll be fine.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products