City Communication Cable transmit audio frequency signals, analog signals up to 150kHz

Ref Price:
Loading Port:
Shanghai
Payment Terms:
TT OR LC
Min Order Qty:
100 m
Supply Capability:
100000 m/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Application

It  is mainly used to transmit audio frequency signals, analog signals up  to 150kHz and the digital signals up to 2048kbit/s; and under certain  conditions, it also can be used to transmit the digital signals above  2048kbit/s. it is suitable to use in the telecom circuit of city, near  suburb and local areas.


Type

Designation

Standard

HYA

Copper  core solid polyolefin insulated plastic coating aluminum tape adhibit  shielding polyolefin jacketed city communication cable

YD/T 322

HYPA

Copper  foam skin polyolefin insulated plastic coating aluminum tape adhibit  shielding polyolefin jacketed city communication cable

HYAT

Copper  core solid polyolefin insulated grease filled plastic coating aluminum  tape adhibit shielding polyolefin jacketed city communication cable

HYPAT

Copper  foam skin polyolefin insulated grease plastic coating aluminum tape  adhibit shielding polyolefin jacketed city communication cable

HYAC

Copper  core solid polyolefin insulated grease filled plastic coating aluminum  tape adhibit shielding polyolefin jacketed self-supporting city  communication cable

HYA23

Copper  core solid polyolefin insulated plastic coating aluminum tape adhibit  shielding polyolefin jacketed and serving double-tape armored city  communication cable

HYAT23

Copper  core solid polyolefin insulated grease filled plastic coating aluminum  tape adhibit shielding polyolefin jacketed and serving double-tape  armored city communication cable

HYA53

Copper  core solid polyolefin insulated plastic coating aluminum tape adhibit  shielding polyolefin jacketed and serving corrugated steel-tape  longitudinal covered armored city communication cable

HYAT53

Copper  core solid polyolefin insulated grease filled plastic coating aluminum  tape adhibit shielding polyolefin jacketed and serving corrugated  steel-tape longitudinal covered armored city communication cable

 

Specification

Type

Conductor diameter

mm

Pair

HYA HYPA HYAC

HYA23 HYA53

0.40

102400

0.50

101600

0.60

101000

0.80

10600

HYAT HYAT23

HYPAT HYAT53

0.40

102000

0.50

101000

0.60

10800

0.80

10400


Technical parameter

No.

content

unit

index

conversion for length

1

DC resistance single conductor

Ω/km

nominal diameter for the conductor(mm) 0.40  0.50  0.60  0.80

             148.0  95.0  65.8  36.6

/L

Actual test value/L

2

DC resistance unbalance for pair

%

  0.40 0.50 0.60 0.80

nominal diameter for the conductor

      1.5  1.5  1.5  1.5

average value

max. value  5.0  5.0  5.0  4.0

3

20℃ insulation resistance between each insulated conductor and the other grounding and shielding conductor   DC 100V~500V

MΩ·km

                                     non filled   filled

min. value    10×103          3×103

Actual test value

Actual test value×L

4

insulated electrical strength  DC

time for voltage force

conductor to conductor

conductor to shield

kV

  solid insulated cable    foam skin insulated cable

3s       1min         3s       1min        

 

2.0       1.0         1.5      0.75        

 

6.0       3.0         6.0       3.0         

5

operating capacitance  0.8kHz或1 kHz

nF/km

       10       >10

nominal pair no.

max. Value    58.0      57.0

average value     52.0±4.0  52.0±2.0  

Actual test value/L

6

capacitance unbalance0.8kHz或1 kHz

capacitance unbalance between pair and pair

capacitance unbalance between pair and ground

pF/km

     10          >10

nominal pair 

max.    250(200)1) 250(200)1)

 

 

min.      2630       2630

average value≤   —      570(490)1)

Actual test value/[0.5

(L+)]

 

Actual test value/L

7

natural attenuation     20

cable with more than 10 pairs:

150 kHz

 

1024 kHz

 

 

 

150 kHz         

 

1024 kHz 

 

 

 

150 kHz

 

1024 kHz

 

 

 

150 kHz         

 

1024 kHz

 

10 pairs

dB/km

nominal diameter mm

               0.40  0.50  0.60  0.80

solid polyolefin insulated cable

average value≤ 12.1  9.0   7.2   5.7

average value≤ 27.3  22.5  18.5  13.7

solid polyolefin insulated filled cable

average value≤ 11.7  8.2   6.7   4.7

average value≤ 23.6  18.6  15.8  12.3

foam skin polyolefin insulated cable

average value≤ 12.6  9.3    7.4   5.8

average value≤ 29.3  24.1  19.8  14.6

foam skin polyolefin insulated filled cable

average value≤ 12.1  9.0   7.2   5.7

average value≤ 26.5  21.8  18.0  13.3

Average value shall not 110% of Max. average value of same type cable above 10 pairs.

Actual test value/L

9

far-end cross-talk defence  150 kHz

合random combination pair to pair

all pair combination between basic unit or 30 pairs

all pair-combination within 12 or 13 sub-unit or 10 pairs and 20 pairs

dB/km

 

 

 

min.           58

 

power average value≥     69

 

 

power average value≥     68

 

 

Actual test value+10lgL

1) Indexes in the bracket are suitable for the cables with conductor diameter of 0.60mm and 0.80mm



 


Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:The living room to the bedroom cable does not work
1 TV inside the 400V filter capacitor damage 2 audio and video cable connection is not good or poor quality 3 you put the TV volume dots, set-top box volume can be improved
Q:What is the difference between KVV and VV cables and are they clearly different?
Is there a problem driver in Device Manager? Should be driven by the problem
Q:Home improvement, the wire specifications generally how to choose? Lighting, sockets, air conditioning with a few square lines? Ground specifications can be lighter than the line of fire, zero line?
Sailing cold drill. The The Cool cold supreme. The The Pioneer (burner). The The
Q:Cable WDZ-YJFE2 (4X185 + 1X95) what does it mean
According to the specification requirements: 8.10 cable bridge wiring 8.10.4 cable bridge horizontal laying, should be selected according to the load curve to support the best span, span should be 1.5-3m. Vertical laying, the fixed point spacing should not be 2m. Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 2 m, then the number of stents required is: (60/2) * 2 = 60 Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 1.5 m The number is: (60 / 1.5) * 2 = 80 mainly depends on your shaft height, and the bridge fixed point spacing, hope to help you, (* ^ __ ^ *)
Q:Apple mobile phone does not support this charge when charging this thing how to charge
People say is right, double heat is not good, line loss big
Q:Construction of hydropower embedded pvc pipe after the solidification of the pipe after the flat tube
Cable model NHYJV3 * 25 + 2 * 16 its name is: fire-resistant cable. NH ----- on behalf of fire. YJV ----- XLPE insulated PVC sheathed power cable. 3 * 25 ----- 3 cable cross section is 25 square (for 3 phase line with). 2 * 16 ----- 2 cable cross section is 16 square (one for the neutral line, one for the ground line). Fire-resistant cables are generally used for TN-S power supply systems (five-wire).
Q:What is the difference between a trough bridge and a tray tray?
Many, with the cable where the requirements should be used bridge.
Q:What is the fire wire pipe laying? What is the galvanized steel pipe?
Another example is the flashlight and electric shaver although the voltage is very low, power and current is very small, is still strong
Q:What are the lines that need to be set up for notebooks?
Friends, shielded cable is a layer of mesh copper or metal wire woven from one or more wires surrounded by a cable, this layer of mesh to prevent lightning, the outside signal can not interfere with it, and control cable is used To control the device to start the protection circuit, etc., in general occasions do not need to shield, with the general insulated wire on it, as long as the load on the line.
Q:What is the length of the wire that affects voltage and electricity
Because the AC operation will produce eddy current, will make the steel pipe and cable heat burned

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing