Black Annealed Tie Wire BWG20 Binding Wire/Loop Annealed Wire/U Type Annealed Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 m.t.
- Supply Capability:
- 3500 m.t./month
OKorder Service Pledge
OKorder Financial Service
You Might Also Like
1. Structure of Black Annealed Iron Wire Description:
Black Annealed Iron is also known as oil painted black iron wire or black mild steel wire, which is offered in the form of coil wire, tie wire or cut into straight wire. Annealed wire can be greased if customer requires. It also comes in the form of cut wire or big coil wire. Black iron wire, also called black wire, comes in the form of coil wire or cut wire. Iron Rod is its raw material.Used for tie wire or binding wire in construction.
Black Annealed Iron Wire widely used in weaving wire mesh, binding wire ,loop wire and cut wire,etc.Annealed Wire is mainly used in construction for binding wire ,and also used in handcraft, such as PVC Chrismas tree, tomato bracket ,tomato trestle,wreath,funeral wreath and so on .
2. Main Features of Black Annealed Iron Wire:
Carbon steel wire with annealed heating treatment
Soften and flexible character
Low costs and economy
Easy to handle or install
Continuous coils and uniform diameters
Various sizes and packages available upon request
Ideal for binding or mesh making
3. Black Annealed Iron Wire Images
4.Black Annealed Iron Wire Specification
Black Annealed Wire | |||
Wire Gauge | SWG(mm) | BWG(mm) | Metric(mm) |
8# | 4.06 | 4.19 | 4.00 |
9# | 3.66 | 3.76 | - |
10# | 3.25 | 3.40 | 3.50 |
11# | 2.95 | 3.05 | 3.00 |
12# | 2.64 | 2.77 | 2.80 |
13# | 2.34 | 2.41 | 2.50 |
14# | 2.03 | 2.11 | - |
15# | 1.83 | 1.83 | 1.80 |
16# | 1.63 | 1.65 | 1.65 |
17# | 1.42 | 1.47 | 1.40 |
18# | 1.22 | 1.25 | 1.20 |
19# | 1.02 | 1.07 | 1.00 |
20# | 0.91 | 0.89 | 0.90 |
21# | 0.81 | 0.813 | 0.80 |
22# | 0.71 | 0.711 | 0.70 |
5. FAQ
We have organized several common questions for our clients,may help you sincerely:
①How about your black annealed wire?
Our company isa professional manufacturer and exporter of metal products. We have 20 years of production experience and our product category has expanded to galvanized wire, black annealed wire, welded wire mesh, welding rod, hexagonal wire netting, chain link fence, barbed wire, stainless steel wire, dutch wire mesh, perforated metal mesh, loop wire, etc
②Q:How do you ship the finished galvanized iron wire?
A:Usually by sea.
③Q:Are you a manufacturer?
A: Yes,we have specialized in this field for more than 4 years experience.
- Q:Wire 1 and wire 2 are made from the same metal. Wire 2 has a larger diameter than wire 1. The electric field strengths E1 and E2 are equal. A) Compare the values of the two current densities. Is J1 greater than, less, or equal to J2?B) Compare the values of the currents I1 and I2. Is I1 greater then, less or equal to I2?
- The current will be more dense in the smaller wire. The value of the current is inversely proportional to the resistiance of the wire. Resistance = resistivity * length / Area since the wires are of identical material and length, the only thing left to vary is the cross-sectional area. Area is proportional to the square of the radius (diameter), so the current will be proportional to the square of the diameter. I2 is proportional to I1^2 I2 is larger than I1 .
- Q:Wire diagram for stereo to a 2000 Kia sportage
- Kia Sportage Radio
- Q:how do you connect two copper wires together
- a wire nut
- Q:I know the ground wire takes unused electricity to the ground but what is the purpose of the neutral wire?
- The neutral wire is supposed to be the wire that functions to take the current from the hot side back to the power line. The ground is there as a safety measure - in 3 wire appliances, the ground is usually connected to the housing. It is there in case some part of the hot circuit becomes shorted to the appliance housing - if that happens on a modern 3-wire electrical system, it will cause the breaker to trip. Or, if the appliance is plugged into a ground fault interrupter GFI, that will generally trip first, before the breaker.
- Q:I like bending paperclips to make things, does anyone know where you could buy spools of the wire paperclips are made out of.(any type of wire that is the same size and material will work)
- For the best answers, search on this site https://shorturl.im/axqI3 No, I am afraid you can't ... you need a special alloy, not paper clips, which are mild steel.
- Q:What is the best brand of wire to use for getting power to my amp?
- Monster cable 10 awg
- Q:I need to get to the audio wiring
- you cannot simply go with matching the colors factory radios have extra wires that are not needed with an aftermarket install most of the time (wires that control the dimmer on the radio, speed sensitive volume) you will need three power wires (constant, ignition, and ground), plus your speaker wires use a test light to test your wires, usually at the radio the yellow wire is your constant, the red is your ignition, and black is always ground to find your constant use the test light, it will be hot at all times so that your radio can remember the time, and your settings- next you need your ignition, it is only hot when the key is on or in the accessory position, to tell the radio when to come on- the ground is self explanatory to find which wires go to what speakers all you need is a 9v battery, put the positive end to a wire and test all of the other wires to the negative side and you will hear a crackling noise from a speaker when you have the right combination
- Q:I have a Trane Heat pump AC/Heat. There are several wires and Im a little stumped? There is a Tan wire*which the book does not show) and a black wire that is labled X1 on the old one but is not in the new ones book? I have also been told NOT TO hook blue wire up to the B port?? But if not, not sure where to put it?
- Generally the blue wire is never used in a 4 wire system. There also is no guarantee that the other wires are correct. Making note before you swapped wires sure would have helped. A little late now. This the normal wiring designation. white= common =goes to C green= fan=goes to G red=heat=goes to R blue I suspect should be yellow which goes to Y and is for cooling. Just attach the blue to Y Your new thermostat should tell you if the jumper is needed. Most come with the jumper already installed. Don't forget to read the section on setting the Heat Anticapater. Electric heat is normally set at .7. Gas would be different.
- Q:I hooked up my Klipsch floor speakers with the old-cheapy wire and then bought, I think it was monster cable, and bi wired it. Big sound improvement. But I've heard pros and cons on monster cable. I have three zones to wire in my house. If I bi wire the other two zones what's the best wire to get? You can spend a small fortune on wire. If I bi wire, zone 2 would be 30 feet x 4 and zone 3 50 feet x 4. I read that if one of the wires is silver it's better as silver's the best conductor. This I knew already. But, when I bought the wire that I did, it didn't state anywhere on the label that it contained silver and I think that would be a drawing point. In fact, I didn't see any wire at that store that said it was part silver and it wasn't Walmart but a major electronics store. I did see some that had silver colored strains but so is steel and aluminum. I also read on another forum that CAT 5 wire works well for bi wiring? Thoughts? Opinion?
- Silver is used in a number of video cables including those made by Monster Cable, but the cost increases greatly with these higher quality cables. To cite and example, a 4ft piece of Monster Cable with silver coated copper conductors runs $150.
- Q:pendant wiring hookup. issue: light is always on house wires: red, white, black, ground pendant wires: green, white, black (and a ground wire to the frame) I did connect red to green, white to white, black to black, ground to ground is connecting the red to green the problem causing the light to be always on? do I just disconnect the red to green to fix?
- No the problem is the black is a constant hot intended for a ceiling fan motor connection. #1) Bare and green are grounds only and no other wire should be attached to them. #2) The red should have been from the switch intended for a light fixture or kit. But it must not be attached to the wall switch or you would have tripped the breaker. I take it there wasn't a light there to start with? Are there any other wires in the ceiling box you didn't mention? If so please edit your question with more detail.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Black Annealed Tie Wire BWG20 Binding Wire/Loop Annealed Wire/U Type Annealed Wire
- Loading Port:
- Tianjin
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 10 m.t.
- Supply Capability:
- 3500 m.t./month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Related keywords