Aluminum Alloy Wire

Ref Price:
$4.00 - 4.50 / kg
Loading Port:
Shanghai
Payment Terms:
L/C,T/T
Min Order Qty:
500 Kilograms kg
Supply Capability:
200 Metric Ton/Metric Tons per Month kg/month

OKorder Service Pledge

Quality Product

Order On-line Tracking

Timely Delivery

OKorder Service Pledge

Credit Rating

Credit Services

Credit Purchasing

Share to:

Product Description:

Aluminum  alloy wire

1.Used for fence,braiding,inner conductor
2.TS:>250mpa
3.Elongation:10%-15%
4.SJ/T11223-2000

SURFACE: smooth and bright color

 

ADVANTAGE:

  • Hard texture:its hardness is several times more than traditional plastic, but the weight is only one-third of the latter

  • light weight

  • low density

  • better heat dissipation

  • high Tensile strength

 

Aluminum Magnesium alloy wire range:

5005, 5052, 5056, 5154, 5356 and the other kinds of 5 series aluminum magnesium alloy wire

 

SPECIFICATION: 0.12mm - 6.5 mm.

 

APPLY TO:

  • Aircraft, transport vehicles, vessels, instruments, metal products

  • Processing to the rivets, Zipper, nails, etc

  • Welding Aluminum Magnesium alloy wire which magnesium content is exceeding 3%

  • Sanitary equipment hose braiding materials, automotive and machinery oil hose material

  • Electronic industries and telecommunications industries

  • Textile shield for power cable

 

  Main index of aluminum-magnesium alloy wire 5154

              Item

           Index

Wire Diameter(mm)

   >0.10±0.003

Aluminum content

   >94(%)

Magnesium content

   2.8-3.8(%)

Tensile strength

   220mpa-310mpa

Electrical conductivity % IACS

   30-56(%)

Elongation

   4%-7%

Resistance rate(MAX)

   0.052mm/m

                                                     

Why we choose Okorder.com?

Okorder.com is a professional and reliable online E-market place

Providing a variety of products with reasonable prices

High quality goods provided by factory suppliers

Shipping to over 200 countries.

One-stop sourcing

Dubai Logistic Complex

 

Okorder Quality Control?

We hold a very strict quality control system to check every connector of our products for your safety.

 

Okorder services for you

1.7*24 hours Hotline & Email Service

2. Your inquiry related to our products or prices will be replied in 24hrs.

3. Well-trained and experienced staffs to answer all your enquires in fluent English

4. OEM&ODM, any your customized demand we can help you to design and put into product.

5. Distributor ship are offered for your unique design and some our current models

 

 

Send a message to us:

Remaining: 4000 characters

- Self introduction

- Required specifications

- Inquire about price/MOQ

Q:How to identify the quality of the lock of the hotel lock?
PE cable that waterproof cable can be a short time to soak the water PE water pipe is used to transmit water to the water pipe than the requirements of the drainage pipe than the cable all PE high hardness
Q:"Cable laying" cable cross-sectional area refers to the cable cross-sectional area, or refers to the copper core cross-sectional area
What kind of clothes do you want to do? General to high-speed sewing machine, the most important three-line lock machine, hot Taiwan, such as a suit to buy a pressure machine, workstations
Q:Cable WDZ-YJFE2 (4X185 + 1X95) what does it mean
According to the specification requirements: 8.10 cable bridge wiring 8.10.4 cable bridge horizontal laying, should be selected according to the load curve to support the best span, span should be 1.5-3m. Vertical laying, the fixed point spacing should not be 2m. Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 2 m, then the number of stents required is: (60/2) * 2 = 60 Assuming that the height of the electrical shaft is 60 m and the fixed point spacing is 1.5 m The number is: (60 / 1.5) * 2 = 80 mainly depends on your shaft height, and the bridge fixed point spacing, hope to help you, (* ^ __ ^ *)
Q:Why does the AC welding machine burn out the equipment?
Electric workers in the wood when the wood bar, buried in the soil that part of the first use of fire char, and then brush into the ground after the bitumen
Q:What are the requirements for the spacing between the strong and weak wires?
Notebook does not have the opportunity to DIY. The reasons are as follows: Notebook motherboard non-versatile motherboard, the shape of the motherboard, positioning holes, screw holes are not uniform standards, each manufacturer's motherboards are their own engineers and then open factory production model. Notebook shell corresponding to the interface location, type and screw hole location is with a specific motherboard supporting.
Q:Power cable 5-color line, respectively, what color, what role?
YJ: XLPE insulation V: PVC sheathed 22: steel tape armor 8.7 / 15KV: rated voltage: 8.7 / 15 kV (phase voltage 8.7 = 15 / 1.. line voltage 15kV) 3 * 300: Three conductor cross-section of 300 square copper conductor Another: If YJLV is the aluminum core. Here is not marked what the material is conductor, you can default to copper conductor.
Q:Whether the interior decoration is the first brush latex paint or the first installation of the wire (the line, with the trunking)?
3 + 2 and 4 + 1 are the number of cores of a cable, a cable inside is not a line, is insulated with each other 2 or . 3 +. 4 +1 line, 5 lines , Respectively, called 2 core or 3 core, 3 +2 core, 4 +1 core, 5 and other core. 3 + 2 cable 3 is the three phase lines, the diameter of the line as large, 2 is the zero line and the PE line, the diameter of the line as large; 4 + 1 cable 4 is the same as the three lines and the same diameter, 1 is the PE ground wire is a separate diameter; five core is the phase line, zero line and PE line are the same diameter, 2 core and 3 core is also the diameter of the line. In the end with a few cable, the design specifications are provided! A few words are not clear!
Q:Power cable casing buried what are the requirements
2 direct laying cable way, should meet the following requirements: 1 cable should be laid in the trenches, and should be along the length of the cable on the next, next to the side of the shop with a thickness of not less than 100mm soft soil or sand 2 along the length of the cable should cover the width of not less than 50mm on both sides of the cable protection board, protective board should adopt concrete 3 urban cable buried in the laying, it is appropriate in the protection board laying eye-catching signs 4 in the suburbs or open areas, along the cable path of the line spacing of 100m, corner or joint parts, should be erected obvious signs or signs 5 when the use of cable through the corrugated pipe laying in the trenches, should be along the full length of the bellows casting thickness of not less than 100mm of concrete, the width should not be less than 50mm outside the tube, the cable can not armor 3 buried in the non-frozen soil area, the cable embedding depth should meet the following requirements: 1 cable to the basement of the basement structure, not less than 03m 2 cable skin to the ground depth, not less than 07m; when located in the carriageway or farmland, should be properly deepened, and should not be less than 10m 4 buried in the permafrost area, should be buried below the permafrost layer, when not buried can be buried in the soil drainage of dry frozen soil or backfill, but also take other measures to prevent damage to the cable The 5 Directly laying the cable, is strictly prohibited in the underground pipe is just above or below The minimum distance between cable and cable, pipe, road, structure, etc shall be in accordance with Table 535 Table 535 Permissible minimum distance between cable and cable, pipe, road, structure, etc (m)
Q:What are the varieties of wire and cable (detailed point)
DJ is a distributed instrument signal cable, also refers to the computer cable, V is PVC. The specific meaning can see the manufacturer's product description.
Q:What recycled rubber is suitable for the production of wire and cable?
Need to choose according to specific circumstances. The main difference between single and multi-core is the flexibility of the wire. In fact the two do not exist which good question, but the use of the environment is not the same. Home decoration: First, the lighting line, can be used 1.5 single strand copper wire. . 2P (inclusive) or more of the air-conditioning, that is, hot water heater, Yuba must use 4 square double strand copper wire; Third, the wall buried the best choice for single wire copper wire, you can choose according to the need for 4 square Mm, 2.5 square millimeters, 1.5 square millimeters and other specifications (usually 2.5 square millimeters with the most). Fourth, the remaining lines, are using ordinary 2.5 pairs of copper wire can be.

1. Manufacturer Overview

Location
Year Established
Annual Output Value
Main Markets
Company Certifications

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port
Export Percentage
No.of Employees in Trade Department
Language Spoken:
b)Factory Information  
Factory Size:
No. of Production Lines
Contract Manufacturing
Product Price Range