Single Core and multi-core PVC Insulated and PVC Sheath Cable 450 /750 V Production Introduction for Single Core and multi-core PVC Insulated and PVC Sheath Cable:
Voltage Rate: 300/500V, 450/750V
Cores: 1~5 cores
Range of Nominal cross section: Single core: 0.75 mm2 ~ 630 mm2
Multicore core: 0.75 mm2 ~ 120 mm2
Conductor: Class 1/2 Plain annealed copper wires, solid or stranded
Constructions: Insulation: PVC
Sheath: PVC
Core color: Brown, Grey, Black, Blue, Green/Yellow or others on request
Max. Operating Temperature: 70℃, can be 90℃,105℃as per requirement
Packing: 100 meter/roll for small size, wooden drum for big size, or as per requirement
Application for Single Core and multi-core PVC Insulated and PVC Sheath Cable:
These cables are used for general purpose, as building wire for power, lighting and control wire to electrical appliances, suitable for use in conduit and for fixed, protected installation.
Production Standard for Single Core and multi-core PVC Insulated and PVC Sheath Cable:
I EC 60227, GB/T5023, VDE0281, BS6004
The Feature for Single Core and multi-core PVC Insulated and PVC Sheath Cable:
The cable can be of flame retardance, fire resistance and other property
Packing photo for Single Core and multi-core PVC Insulated and PVC Sheath Cable:
FAQ For Single Core and multi-core PVC Insulated and PVC Sheath Cable:
Q1:What is the Production Capacity for your factory?
About 50 kilometer every day
Q2: What is the Minimum Order Quantity For Single Core PVC Insulated Cable 450 /750 V?
MOQ: 10000 meters for small size, 5000 meters for middle size, 1000 meters for big size
Q3:What is the delivery time for these cables?
10~15 working days
Q4: What standards is the product complying with?
We can produce thousands of electric wires and power cables complying with different standards, such as: GB, JB , IEC, BS, AS/NZS, VDE, UL ETC.
- Q:The difference between a fire resistant cable and a general power cable
- We usually say how many square millimeters (wire) refers to the cross-sectional area of the wire core, that is, according to the diameter of the core calculated cross-sectional area. The larger the cross-sectional area of the wire, the greater the capacity of the power transmission.
- Q:I'm looking to add another Light fixture on the other side of the garage, and wire it using the existing cable from the first light, I know running a normal power cable outside drywall is against code, but I've heard some people say you can use something like BX cable, or some metal encased cable outside of drywall and still be up to code? Is there a I can run this cable outside of the drywall using something like that, and if yes, what exactly would I need to use to accomplish this? I plan I running the wire from the right side of the garage door, up above the door, and to the left side of the door to install a matching light.
- If exposed, you must use an armored cable or conduit. No if's, and's, or but's... Personally, I think conduit is your best option.
- Q:what cables do i need (besides a power cable) to start playing?
- 1). PS AV cable for standard TVs; 2). HDMI 1.3a for HDTVs; 3). RJ-45 cable if you plan a wired internet connection; 4). SB - miniB cable for controller; 5). Power cable (same as for PC).
- Q:I lost my PS3 power cable but I got one from an old pc and it does work but am i better off using my old cable?Does it affect my PS3's performance?
- Mmm well a cable is a cable if it is a three pin one then it is fine. With powercables you need a certain thickness of the cable for safety. PC cables are able to run 1000Watt... so a 200Watt console is no trouble.
- Q:ok, i want to install and upgrade the sound system in my car, volkswagen 2006, but i dont know where to run the power cable from the battery in engine compartment to the trunk where i place the amplifiers, anyone who knows, please help me out. thanks
- from the trunk down the side of the car (pop open the panels that sit on the bottom where the door closes. run the wire thru the firewall grommet where the ignition and internal power wires run thru. Use a coat hanger duct taped to the power wire to get it thru. should go thru with some pressure. just finished dropping in an amp in my accord.
- Q:Also why is it called quot;phantompower? Don't you think there should be a seperate category for technical questions about music!!?
- Yes, you can use regular XLR cables for microphones that require phantom power. The only reason why some microphones require phantom power is because they require extra voltage flowing through the XLR cable. Condenser mics are the most commonly used mics that require phantom power, mainly because of the way the diaphram picks up sound (condenser mics pic up sound in a narrower area around the mic, yet can pick up distant sounds somewhat better). It earned the name phantom because it is invisible to other balanced (non-condensing, etc.) mics that don't need the extra power. A tech section would make it easier on most of us, because most of the important questions get lost in the typical whuz you're fav song or need lyrics plz questions that flood the section.
- Q:computer MB does not contain a power supply connector for the SATA power cable leading to the SATA HD, is this the norm? the cable connector is 5 prong female, there is no 5 prong male connector on the MB or the PSU. any suggestions?
- You okorder /
- Q:My laptop power cable is bust and i need a new one for my Acer laptop, please can someone tell me where i can purchase one?Thankyou very much!
- I okorder /
- Q:what would happen if i used a 10 guage power cable on a 2400 watt amp, would it blow the fuse of would the amp just creat less power? thnx
- The wire could heat up causing damage, however it would likely just create less power
- Q:HiIs it advisable to run 110VAC cable from the sub stationa and 110VAC cable from generator (clean) in the same conduit ; one of them for lighting and the other for CCTV; the concern is if the one for lighting is not clean (not consisting of a pure sine wave or carrying interference) would that effect the power line of the CCTV and has an effect on the picture? even though both are 110VAC.the installation is over seas where the power from the station is not consistence.
- If both are simple power lines, then you won't have a problem. The only time you need to be cautious is when you are running a high-voltage power cable and a signal cable alongside each other e.g. a 110VAC cable alongside a 4-20ma signal line from a transmitter. The reason for the potential interference is that the power cable emits an electro-magnetic field which can potentially cause induction in the cable alongside it and effect the signal with an induced EMF. The likelihood of this depends on the cable type, screening and correct earthing measures. It's a good bet to never run a power and signal cable alongside each other, and if you have no other choice, seperate them by means of a makeshift Faraday Cage. If both are doing nothing other than supplying power to the system though, then any induced EMF will be so minute, it will not likely affect the system in any way.
1. Manufacturer Overview |
|
---|---|
Location | |
Year Established | |
Annual Output Value | |
Main Markets | |
Company Certifications |
2. Manufacturer Certificates |
|
---|---|
a) Certification Name | |
Range | |
Reference | |
Validity Period |
3. Manufacturer Capability |
|
---|---|
a)Trade Capacity | |
Nearest Port | |
Export Percentage | |
No.of Employees in Trade Department | |
Language Spoken: | |
b)Factory Information | |
Factory Size: | |
No. of Production Lines | |
Contract Manufacturing | |
Product Price Range |
Send your message to us
Single Core and multi-core PVC Insulated and PVC Sheath Cable 450 /750 V NYM
- Loading Port:
- Shanghai
- Payment Terms:
- TT OR LC
- Min Order Qty:
- 1000 m
- Supply Capability:
- 3000 m/month
OKorder Service Pledge
OKorder Financial Service
Similar products
New products
Hot products
Hot Searches
Related keywords