Specification of Weaving Machinery B

 

1. special medical gauze & bandage weaving machine,plain fabric

2. Machine working width:150cm

3. Fabric max width:145cm

4. Fabric min width:80cm

5. R.P.M:500-600

6. Mechanical take-up,mechanical let-off

7. Thread count:7-20pick per inch

8. Cotton yarn:25s-40s

9. warp beam diameter:800mm ,cloth roller diameter will be 800mm at most.

10. if install big package,the cloth roller diameter will be 1200mm at most.

11. Production capacity:depends on thread count and R.P.M

e.g thread count is 15pick per inch,R.P.M is 600.the production per hour should be 61m/h

Mostly,the production capacity is more than 1000 meter per day.

10. loom motor power:1.3kw

11. electricity consumption:1.5kw/h

12. air consumption:0

13.one air pump is installed in the machine

 

 

Packaging & Delivery of Weaving Machinery B


Packaging Detail: standard packing.. 

Delivery Detail: within 30 days after get the T/T payment..

 

 

Features of Weaving Machinery B


Good manufactuer, Independent air feed system high performance, closed selvedge, low cost

 

 

 

Q:What is the working principle of centrifugal fans?
The pressure generated in the centrifugal fan is greatly influenced by changes in the inlet temperature or density. For a given intake air volume, the maximum intake air temperature (lowest air density) produces the lowest pressure. For a given pressure and flow characteristic curve, there is a power and flow characteristic curve. When the blower runs at constant speed , The required power increases with a decrease in the intake air temperature for a given flow rate.
Q:What is the fan D drive?
Fan impeller cantilever support, pulley between the two bearings V-belt drive;
Q:What are the characteristics of high-pressure axial fans?
5. The highest quality After 17 years of professional manufacturing experience, the most sophisticated mechanical design plus prudent motor with standard equipment testing, the use of all parts can achieve the highest quality requirements, the use of standard ip54
Q:How to reduce fan noise?
3) centrifugal outlet due to the presence of the volute or the presence of the fan-shaped fan rear guide leaves produced by the presence of interference noise, discrete noise with discrete spectral characteristics, the fundamental frequency (i = 1 corresponding to the frequency) the strongest noise , Higher harmonics are decreasing.
Q:What is the critical speed of the fan?
Fan rotor in the operation will occur in the vibration, the rotor amplitude increases with the increase in speed to a certain speed to reach the maximum amplitude (that is, usually said resonance)
Q:What are the regulations for the air volume of the exhaust fan?
For a smoke-free partition or smoke clearance height greater than 6.0m non-smoke partition of the room, should be based on the area per square meter of not less than 60m3 / h (single fan minimum smoke should not be less than 7200m3 / H
Q:What is the role of ion fan?
The main role of the ion fan is: In addition to static electricity, with excellent in addition to static performance, to prevent electrostatic pollution and damage.
Q:What is the meaning of the residual pressure in the fan equipment parameters?
On the machine outside the pressure in the end is the machine outside the full pressure or external pressure Is the full pressure outside the machine. Write outside the static pressure is usually measured when the dynamic pressure as 0. It can be seen that the concept of external pressure is not a standard concept, but must be taken into account the pressure loss of the unit itself can provide the full pressure.
Q:380V axial fan has five lines how to take?
If it is three-phase 380V axial fan, the coil DC resistance is not the same, indicating that the motor is broken, can not be wired
Q:Why the blower suddenly does not turn?
Check the above are normal circumstances, you can ask the relevant management personnel, the factory there is a phenomenon in the power flash.
We are a well-known enterprise specializing in the production and sales of textile machinery,Since the establishment of our company, we have been devoted to setting up a good quality management system.

1. Manufacturer Overview

Location Yantai, China
Year Established 1997
Annual Output Value 500Setyear
Main Markets Mid East; Eastern Europe; Westen Europen
Company Certifications ISO 9001

2. Manufacturer Certificates

a) Certification Name  
Range  
Reference  
Validity Period  

3. Manufacturer Capability

a)Trade Capacity  
Nearest Port Qingdao
Export Percentage 40%
No.of Employees in Trade Department 1000 People
Language Spoken: English; Chinese
b)Factory Information  
Factory Size: 50000square meters
No. of Production Lines Above20
Contract Manufacturing OEM Service Offered
Product Price Range Average

Send your message to us

This is not what you are looking for? Post Buying Request

Similar products

New products

Hot products


Related keywords